Simultaneous in vivo positron emission tomography and magnetic resonance imaging
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Positron emission tomography (PET) and magnetic resonance imaging (MRI) are widely used in vivo imaging technologies with both clinical and biomedical research applications. The strengths of MRI include high-resolution, high-contrast morphologic imaging of soft tissues; the ability to image physiologic parameters such as diffusion and changes in oxygenation level resulting from neuronal stimulation; and the measurement of metabolites using chemical shift imaging. PET images the distribution of biologically targeted radiotracers with high sensitivity, but images generally lack anatomic context and are of lower spatial resolution. Integration of these technologies permits the acquisition of temporally correlated data showing the distribution of PET radiotracers and MRI contrast agents or MR-detectable metabolites, with registration to the underlying anatomy. An MRI-compatible PET scanner has been built for biomedical research applications that allows data from both modalities to be acquired simultaneously. Experiments demonstrate no effect of the MRI system on the spatial resolution of the PET system and <10% reduction in the fraction of radioactive decay events detected by the PET scanner inside the MRI. The signal-to-noise ratio and uniformity of the MR images, with the exception of one particular pulse sequence, were little affected by the presence of the PET scanner. In vivo simultaneous PET and MRI studies were performed in mice. Proof-of-principle in vivo MR spectroscopy and functional MRI experiments were also demonstrated with the combined scanner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Molecular imaging of cancer with positron emission tomography
Gambhir, S. S. (2002) · Nature Reviews Cancer · doi:10.1038/nrc882 · Cited by 1,656
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Positron emission tomography provides molecular imaging of biological processes
Phelps, M. E. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.16.9226 · Cited by 1,229
Magnetic relaxation switches capable of sensing molecular interactions
Perez, J. M., Josephson, L., O'Loughlin, T., Högemann, D., & Weissleder, R. (2002) · Nature Biotechnology · doi:10.1038/nbt720 · Cited by 889
(2002) · Elsevier eBooks · doi:10.1016/b978-0-12-693019-1.x5000-x · Cited by 710
Functional imaging of the monkey brain
Logothetis, N. K., Guggenberger, H., Peled, S., & Pauls, J. (1999) · Nature Neuroscience · doi:10.1038/9210 · Cited by 540
Magnetic resonance spectroscopy of the human brain
Ross, B., & Bluml, S. (2001) · The Anatomical Record · doi:10.1002/ar.1058 · Cited by 411
Simultaneous PET and MR imaging
Shao, Y., Cherry, S. R., Farahani, K., Meadors, K., Siegel, S., Silverman, R. W., & Marsden, P. K. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/10/010 · Cited by 374
Self-citationCatana, C., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., & Cherry, S. R. (2006) · PubMed · Cited by 350
Self-citationAmide proton transfer imaging of human brain tumors at 3T
Jones, C. K., Schlosser, M. J., van Zijl, P. C. M., Pomper, M. G., Golay, X., & Zhou, J. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20989 · Cited by 339
NMR and its Applications to Living Systems
Gadian, D. G. (1996) · doi:10.1093/oso/9780198552819.001.0001 · Cited by 287
Modo, M., Cash, D., Mellodew, K., Williams, S. C. R., Fraser, S. E., Meade, T. J., Price, J., & Hodges, H. (2002) · NeuroImage · doi:10.1006/nimg.2002.1194 · Cited by 268
Evaluation of cancer therapy using diffusion magnetic resonance imaging.
Ross, B. D., Moffat, B. A., Lawrence, T. S., Mukherji, S. K., Gebarski, S. S., Quint, D. J., Johnson, T. D., Junck, L., Robertson, P. L., Muraszko, K. M., et al. (2003) · PubMed · Cited by 257
van Zijl, P. C. M., Zhou, J., Mori, N., Payen, J., Wilson, D., & Mori, S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10398 · Cited by 230
Moffat, B. A., Chenevert, T. L., Meyer, C. R., Mckeever, P. E., Hall, D. E., Hoff, B. A., Johnson, T. D., Rehemtulla, A., & D. Ross, B. (2006) · Neoplasia · doi:10.1593/neo.05844 · Cited by 196
PET: Physics, Instrumentation, and Scanners
Cherry, S. R., & Dahlbom, M. (2006) · PET · doi:10.1007/0-387-34946-4_1 · Cited by 181
Self-citationPET/MR Images Acquired with a Compact MR-compatible PET Detector in a 7-T Magnet
Judenhofer, M. S., Catana, C., Swann, B. K., Siegel, S. B., Jung, W.-I., Nutt, R. E., Cherry, S. R., Claussen, C. D., & Pichler, B. J. (2007) · Radiology · doi:10.1148/radiol.2443061756 · Cited by 173
Self-citationMonitoring Cell Therapy Using Iron Oxide MR Contrast Agents
M. Bulte, J., & Kraitchman, D. (2004) · Current Pharmaceutical Biotechnology · doi:10.2174/1389201043376526 · Cited by 172
Development of a Combined microPET®-MR System
Lucas, A. J., Hawkes, R. C., Ansorge, R. E., Williams, G. B., Nutt, R., Clark, J. C., Fryer, T. D., & Carpenter, T. A. (2006) · Technology in Cancer Research & Treatment · doi:10.1177/153303460600500405 · Cited by 157
Pajevic, S., Aldroubi, A., & Basser, P. J. (2002) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2452 · Cited by 155
Diffusion-weighted MR of the brain: methodology and clinical application.
Mascalchi, M., Filippi, M., Floris, R., Fonda, C., Gasparotti, R., & Villari, N. (2005) · PubMed · Cited by 149
Dafni, H., Landsman, L., Schechter, B., Kohen, F., & Neeman, M. (2002) · NMR in Biomedicine · doi:10.1002/nbm.724 · Cited by 101
High field MRI in preclinical research
Marzola, P., Osculati, F., & Sbarbati, A. (2003) · European Journal of Radiology · doi:10.1016/j.ejrad.2003.08.007 · Cited by 99
Molecular and Functional Imaging of Cancer: Advances in MRI and MRS
Pathak, A. P., Gimi, B., Glunde, K., Ackerstaff, E., Artemov, D., & Bhujwalla, Z. M. (2004) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(04)86001-4 · Cited by 94
Positron emission tomography within a magnetic field using photomultiplier tubes and lightguides
Christensen, N. L., Hammer, B. E., Heil, B., & Fetterly, K. A. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/4/014 · Cited by 94
High‐resolution isotropic 3D diffusion tensor imaging of the human brain
Golay, X., Jiang, H., van Zijl, P. C. M., & Mori, S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10143 · Cited by 71
High-resolution functional magnetic resonance imaging of the animal brain
Kim, S., & Uǧurbil, K. (2003) · Methods · doi:10.1016/s1046-2023(03)00005-7 · Cited by 71
Functional magnetic resonance imaging: imaging techniques and contrast mechanisms
Howseman, A. M., & Bowtel, R. W. (1999) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1999.0473 · Cited by 69
Gustafsson, B. I., Youens, S., & Louie, A. Y. (2006) · Bioconjugate Chemistry · doi:10.1021/bc060018k · Cited by 43
Molecular insights into neurodevelopmental and neurodegenerative diseases
Pettegrew, J. W., Klunk, W. E., Panchalingam, K., McClure, R. J., & Stanley, J. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(00)00376-2 · Cited by 28
Morris, P. G. (1999) · Journal of Psychopharmacology · doi:10.1177/026988119901300403 · Cited by 16
Cited by
The role of porphyrin chemistry in tumor imaging and photodynamic therapy
Ethirajan, M., Chen, Y., Joshi, P., & Pandey, R. K. (2011) · Chem. Soc. Rev. · doi:10.1039/b915149b · Cited by 2,034
Chemical Design and Synthesis of Functionalized Probes for Imaging and Treating Tumor Hypoxia
Liu, J.-N., Bu, W., & Shi, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00525 · Cited by 838
Modern Diagnostic Imaging Technique Applications and Risk Factors in the Medical Field: A Review
Hussain, S., Mubeen, I., Ullah, N., Shah, S. S. U. D., Khan, B. A., Zahoor, M., Ullah, R., Khan, F. A., & Sultan, M. A. (2022) · BioMed Research International · doi:10.1155/2022/5164970 · Cited by 787
Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd'hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712
Evidence for brain glial activation in chronic pain patients
Loggia, M. L., Chonde, D. B., Akeju, O., Arabasz, G., Catana, C., Edwards, R. R., Hill, E., Hsu, S., Izquierdo-Garcia, D., Ji, R.-R., et al. (2015) · Brain · doi:10.1093/brain/awu377 · Cited by 503
Self-citation
Metadata
- Authors
- Catana, C., Procissi, D., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., Jacobs, R. E., & Cherry, S. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-03-11
- Volume
- 105
- Issue
- 10
- Pages
- 3705-3710
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2092726542
- Cited by
- 272
- References
- 32
- FWCI
- 25.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.