Flexible electrical recording from cells using nanowire transistor arrays
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Semiconductor nanowires (NWs) have unique electronic properties and sizes comparable with biological structures involved in cellular communication, thus making them promising nanostructures for establishing active interfaces with biological systems. We report a flexible approach to interface NW field-effect transistors (NWFETs) with cells and demonstrate this for silicon NWFET arrays coupled to embryonic chicken cardiomyocytes. Cardiomyocyte cells were cultured on thin, optically transparent polydimethylsiloxane (PDMS) sheets and then brought into contact with Si-NWFET arrays fabricated on standard substrates. NWFET conductance signals recorded from cardiomyocytes exhibited excellent signal-to-noise ratios with values routinely >5 and signal amplitudes that were tuned by varying device sensitivity through changes in water gate–voltage potential, V g . Signals recorded from cardiomyocytes for V g from −0.5 to +0.1 V exhibited amplitude variations from 31 to 7 nS whereas the calibrated voltage remained constant, indicating a robust NWFET/cell interface. In addition, signals recorded as a function of increasing/decreasing displacement of the PDMS/cell support to the device chip showed a reversible >2× increase in signal amplitude (calibrated voltage) from 31 nS (1.0 mV) to 72 nS (2.3 mV). Studies with the displacement close to but below the point of cell disruption yielded calibrated signal amplitudes as large as 10.5 ± 0.2 mV. Last, multiplexed recording of signals from NWFET arrays interfaced to cardiomyocyte monolayers enabled temporal shifts and signal propagation to be determined with good spatial and temporal resolution. Our modular approach simplifies the process of interfacing cardiomyocytes and other cells to high-performance Si-NWFETs, thus increasing the experimental versatility of NWFET arrays and enabling device registration at the subcellular level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theoretical Neuroscience: Computational and Mathematical Modeling of Neural Systems
Dayan, P., & Abbott, L. F. (2001) · Cited by 4,162
Ion Channels/Excitable Membranes
(2011) · SpringerReference · doi:10.1007/springerreference_33998 · Cited by 4,034
Exploring and Engineering the Cell Surface Interface
Stevens, M. M., & George, J. H. (2005) · Science · doi:10.1126/science.1106587 · Cited by 2,607
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436 · cited 3×
“Passivated source and drain electrodes were deposited by using a multilayer photoresist structure (14, 20, 23, 29) consisting of 300-nm LOR3A (Microchem) and 500-nm 1805 (Shipley).”
MethodSelf-citationCardiac Electrophysiology: From Cell to Bedside
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1069_5 · Cited by 2,385
Ion Channels/Excitable Membranes
Terlau, H., & Kirchhoff, F. (2006) · Encyclopedic Reference of Genomics and Proteomics in Molecular Medicine · doi:10.1007/3-540-29623-9_5640 · Cited by 1,789
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258 · cited 3×
“Passivated source and drain electrodes were deposited by using a multilayer photoresist structure (14, 20, 23, 29) consisting of 300-nm LOR3A (Microchem) and 500-nm 1805 (Shipley).”
MethodSelf-citationNanosize and Vitality: TiO2 Nanotube Diameter Directs Cell Fate
Park, J., Bauer, S., von der Mark, K., & Schmuki, P. (2007) · Nano Letters · doi:10.1021/nl070678d · Cited by 1,193
Activation of Integrin Function by Nanopatterned Adhesive Interfaces
Arnold, M., Cavalcanti‐Adam, E. A., Glass, R., Blümmel, J., Eck, W., Kantlehner, M., Kessler, H., & Spatz, J. P. (2004) · ChemPhysChem · doi:10.1002/cphc.200301014 · Cited by 1,164
Cited by
Nanotechnological strategies for engineering complex tissues
Dvir, T., Timko, B. P., Kohane, D. S., & Langer, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.246 · Cited by 1,367
“or cultured separately on polymer films that were then brought into direct contact with nanowire array”
BackgroundSelf-citationNanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
“…the nanoscale size of the sensors that enabled its insertion into the cytosol through the plasma membrane of the cells, (b) the formation of GΩ resistance between the plasma membrane and the nanostructures, (c) the fact that the size of the sensing area does not affect its sensitivity 78,81,82 .”
Background25th Anniversary Article: Semiconductor Nanowires – Synthesis, Characterization, and Applications
Dasgupta, N. P., Sun, J., Liu, C., Brittman, S., Andrews, S. C., Lim, J., Gao, H., Yan, R., & Yang, P. (2014) · Advanced Materials · doi:10.1002/adma.201305929 · Cited by 880
Three-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes
Tian, B., Cohen-Karni, T., Qing, Q., Duan, X., Xie, P., & Lieber, C. M. (2010) · Science · doi:10.1126/science.1192033 · Cited by 798
Self-citationChen, K.-I., Li, B.-R., & Chen, Y.-T. (2011) · Nano Today · doi:10.1016/j.nantod.2011.02.001 · Cited by 645
Kim, R.-H., Kim, D.-H., Xiao, J., Kim, B. H., Park, S.-I., Panilaitis, B., Ghaffari, R., Yao, J., Li, M., Liu, Z., et al. (2010) · Nature Materials · doi:10.1038/nmat2879 · Cited by 637
“There is growing interest in the use of organic and inorganic micro/nanomaterials in similarly unusual forms on plasti”
BackgroundZhang, A., & Lieber, C. M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00608 · Cited by 621
Self-citationRemotely Triggerable Drug Delivery Systems
Timko, B. P., Dvir, T., & Kohane, D. S. (2010) · Advanced Materials · doi:10.1002/adma.201002072 · Cited by 614
Self-citationA Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Intracellular recordings of action potentials by an extracellular nanoscale field-effect transistor
Duan, X., Gao, R., Xie, P., Cohen-Karni, T., Qing, Q., Choe, H. S., Tian, B., Jiang, X., & Lieber, C. M. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2011.223 · Cited by 456
Self-citationGraphene and Nanowire Transistors for Cellular Interfaces and Electrical Recording
Cohen-Karni, T., Qing, Q., Li, Q., Fang, Y., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl1002608 · Cited by 386
Self-citationProgress and Prospects in Transition-Metal Dichalcogenide Research Beyond 2D
Chowdhury, T., Sadler, E. C., & Kempa, T. J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00505 · Cited by 358
Transparent, Flexible, All-Reduced Graphene Oxide Thin Film Transistors
He, Q., Wu, S., Gao, S., Cao, X., Yin, Z., Li, H., Chen, P., & Zhang, H. (2011) · ACS Nano · doi:10.1021/nn201118c · Cited by 328
Long, Y.-Z., Yu, M., Sun, B., Gu, C.-Z., & Fan, Z. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15335a · Cited by 318
Liu, H., Bolonduro, O. A., Hu, N., Ju, J., Rao, A. A., Duffy, B. M., Huang, Z., Black, L. D., & Timko, B. P. (2020) · Nano Letters · doi:10.1021/acs.nanolett.0c00076 · Cited by 203
Self-citationDai, X., Zhou, W., Gao, T., Liu, J., & Lieber, C. M. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.96 · Cited by 202
Self-citationNanowire transistor arrays for mapping neural circuits in acute brain slices
Qing, Q., Pal, S. K., Tian, B., Duan, X., Timko, B. P., Cohen-Karni, T., Murthy, V. N., & Lieber, C. M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0914737107 · Cited by 197
“In addition, the conductance response of the NWFETs, when converted to external potential change using the sensitivity of the devices (22, 24), corresponds to 0.”
BackgroundMethodSelf-citationBiomaterials‐Based Electronics: Polymers and Interfaces for Biology and Medicine
Muskovich, M., & Bettinger, C. J. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200071 · Cited by 182
Al2O3/Silicon NanoISFET with Near Ideal Nernstian Response
Chen, S., Bomer, J. G., Carlen, E. T., & van den Berg, A. (2011) · Nano Letters · doi:10.1021/nl200623n · Cited by 164
Timko, B. P., Cohen-Karni, T., Qing, Q., Tian, B., & Lieber, C. M. (2010) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2009.2031807 · Cited by 114
“Adapted from [ 73 ] (National Academy of Sciences, copyright 2009).”
BackgroundMethodInfluentialSelf-citationMacroporous nanowire nanoelectronic scaffolds for synthetic tissues
Tian, B., Liu, J., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., & Lieber, C. M. (2012) · Nature Materials · doi:10.1038/nmat3404 · Cited by 20
Self-citationBiotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
Metadata
- Authors
- Cohen-Karni, T., Timko, B. P., Weiss, L. E., & Lieber, C. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2009-05-05
- Volume
- 106
- Issue
- 18
- Pages
- 7309-7313
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2077854881
- Cited by
- 218
- References
- 34
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.