Flexible electrical recording from cells using nanowire transistor arrays
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Semiconductor nanowires (NWs) have unique electronic properties and sizes comparable with biological structures involved in cellular communication, thus making them promising nanostructures for establishing active interfaces with biological systems. We report a flexible approach to interface NW field-effect transistors (NWFETs) with cells and demonstrate this for silicon NWFET arrays coupled to embryonic chicken cardiomyocytes. Cardiomyocyte cells were cultured on thin, optically transparent polydimethylsiloxane (PDMS) sheets and then brought into contact with Si-NWFET arrays fabricated on standard substrates. NWFET conductance signals recorded from cardiomyocytes exhibited excellent signal-to-noise ratios with values routinely >5 and signal amplitudes that were tuned by varying device sensitivity through changes in water gate–voltage potential, V g . Signals recorded from cardiomyocytes for V g from −0.5 to +0.1 V exhibited amplitude variations from 31 to 7 nS whereas the calibrated voltage remained constant, indicating a robust NWFET/cell interface. In addition, signals recorded as a function of increasing/decreasing displacement of the PDMS/cell support to the device chip showed a reversible >2× increase in signal amplitude (calibrated voltage) from 31 nS (1.0 mV) to 72 nS (2.3 mV). Studies with the displacement close to but below the point of cell disruption yielded calibrated signal amplitudes as large as 10.5 ± 0.2 mV. Last, multiplexed recording of signals from NWFET arrays interfaced to cardiomyocyte monolayers enabled temporal shifts and signal propagation to be determined with good spatial and temporal resolution. Our modular approach simplifies the process of interfacing cardiomyocytes and other cells to high-performance Si-NWFETs, thus increasing the experimental versatility of NWFET arrays and enabling device registration at the subcellular level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theoretical Neuroscience: Computational and Mathematical Modeling of Neural Systems
Dayan, P., & Abbott, L. F. (2001) · Cited by 4,162
Ion Channels/Excitable Membranes
(2011) · SpringerReference · doi:10.1007/springerreference_33998 · Cited by 4,034
Exploring and Engineering the Cell Surface Interface
Stevens, M. M., & George, J. H. (2005) · Science · doi:10.1126/science.1106587 · Cited by 2,607
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436 · cited 3×
“Passivated source and drain electrodes were deposited by using a multilayer photoresist structure (14, 20, 23, 29) consisting of 300-nm LOR3A (Microchem) and 500-nm 1805 (Shipley).”
MethodSelf-citationCardiac Electrophysiology: From Cell to Bedside
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1069_5 · Cited by 2,385
Ion Channels/Excitable Membranes
Terlau, H., & Kirchhoff, F. (2006) · Encyclopedic Reference of Genomics and Proteomics in Molecular Medicine · doi:10.1007/3-540-29623-9_5640 · Cited by 1,789
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258 · cited 3×
“Passivated source and drain electrodes were deposited by using a multilayer photoresist structure (14, 20, 23, 29) consisting of 300-nm LOR3A (Microchem) and 500-nm 1805 (Shipley).”
MethodSelf-citationNanosize and Vitality: TiO2 Nanotube Diameter Directs Cell Fate
Park, J., Bauer, S., von der Mark, K., & Schmuki, P. (2007) · Nano Letters · doi:10.1021/nl070678d · Cited by 1,193
Activation of Integrin Function by Nanopatterned Adhesive Interfaces
Arnold, M., Cavalcanti‐Adam, E. A., Glass, R., Blümmel, J., Eck, W., Kantlehner, M., Kessler, H., & Spatz, J. P. (2004) · ChemPhysChem · doi:10.1002/cphc.200301014 · Cited by 1,164
Basic Mechanisms of Cardiac Impulse Propagation and Associated Arrhythmias
KLÉBER, A. G., & RUDY, Y. (2004) · Physiological Reviews · doi:10.1152/physrev.00025.2003 · Cited by 1,083 · cited 1×
“Over the past several decades, studies of electroactive cells have been carried out by using a variety of recording techniques, including glass micropipette intracellular and patch-clamp electrodes (1, 3), voltage-sensitive dyes (4, 5), multielectrode arrays (MEAs) (6–8), and planar FETs (9–11).”
BackgroundPatolsky, F., Timko, B. P., Yu, G., Fang, Y., Greytak, A. B., Zheng, G., & Lieber, C. M. (2006) · Science · doi:10.1126/science.1128640 · Cited by 832
Self-citationPatolsky, F., Zheng, G., & Lieber, C. M. (2006) · Nature Protocols · doi:10.1038/nprot.2006.227 · Cited by 748 · cited 3×
“Passivated source and drain electrodes were deposited by using a multilayer photoresist structure (14, 20, 23, 29) consisting of 300-nm LOR3A (Microchem) and 500-nm 1805 (Shipley).”
MethodSelf-citationCardiac Electrophysiology: From Cell to Bedside
Kuo, P. T. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03460140109039 · Cited by 708
Label-free detection of DNA hybridization using carbon nanotube network field-effect transistors
Star, A., Tu, E., Niemann, J., Gabriel, J.-C. P., Joiner, C. S., & Valcke, C. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504146103 · Cited by 670
Layer-by-Layer Assembly of Nanowires for Three-Dimensional, Multifunctional Electronics
Javey, A., Nam, Friedman, R. S., Yan, H., & Lieber, C. M. (2007) · Nano Letters · doi:10.1021/nl063056l · Cited by 597 · cited 1×
“Briefly, aligned Si NWs are assembled on the surface of an oxidized silicon substrate by using shear transfer (30), and then metal source/drain electrodes and interconnects are defined by using photolithography.”
Self-citationCarbon nanotubes might improve neuronal performance by favouring electrical shortcuts
Cellot, G., Cilia, E., Cipollone, S., Rancic, V., Sucapane, A., Giordani, S., Gambazzi, L., Markram, H., Grandolfo, M., Scaini, D., et al. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2008.374 · Cited by 524
Carbon nanotube transistors for biosensing applications
Gruner, G. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3400-4 · Cited by 408
Nanowire-Based Nanoelectronic Devices in the Life Sciences
Patolsky, F., Timko, B. P., Zheng, G., & Lieber, C. M. (2007) · MRS Bulletin · doi:10.1557/mrs2007.47 · Cited by 342
Self-citationNanotechnology for Cell–Substrate Interactions
Sniadecki, N. J., Desai, R. A., Ruiz, S. A., & Chen, C. S. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9006-3 · Cited by 321
Electrical Recording from Hearts with Flexible Nanowire Device Arrays
Timko, B. P., Cohen-Karni, T., Yu, G., Qing, Q., Tian, B., & Lieber, C. M. (2009) · Nano Letters · doi:10.1021/nl900096z · Cited by 215 · cited 1×
“The improvement in peak amplitude is consistent with the fact that the nanodevices protrude from the plane of substrate and hence can increase NW/cell interfacial coupling (17, 24–28) and with our previous studies of cultured neurons (14) and embryonic hearts (15).”
ResultSelf-citationHalbach, M., Egert, U., Hescheler, J., & Banach, K. (2003) · Cellular Physiology and Biochemistry · doi:10.1159/000074542 · Cited by 199
Gheith, M. K., Sinani, V. A., Wicksted, J. P., Matts, R. L., & Kotov, N. A. (2005) · Advanced Materials · doi:10.1002/adma.200500366 · Cited by 163
Micro-Electrode Arrays in Cardiac Safety Pharmacology
Meyer, T. S., Boven, K.-H., nther, E. G., & Fejtl, M. (2004) · Drug Safety · doi:10.2165/00002018-200427110-00002 · Cited by 134
Practical Methods in Cardiovascular Research
Dhein, S., Mohr, F. W., & Delmar, M. (2005) · Springer eBooks · doi:10.1007/b137833 · Cited by 133
CMOS‐Compatible Nanowire Sensor Arrays for Detection of Cellular Bioelectricity
Pui, T. S., Agarwal, A., Ye, F., Balasubramanian, N., & Chen, P. (2009) · Small · doi:10.1002/smll.200800919 · Cited by 116
Thin-Film Multiple Electrode Probes: Possibilities and Limitations
Prohaska, O. J., Olcaytug, F., Pfundner, P., & Dragaun, H. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325894 · Cited by 103 · cited 1×
“The latter 2 recording techniques use welldeveloped microfabrication methods to allow for direct multiplexed detection on a scale not possible with micropipette technology, although the MEAs and FETs exhibit limited signalto-noise ratios (S/N) and detection areas that make cellular and subcellular recording difficult…”
MethodCardiomyocyte-transistor-hybrids for sensor application
Ingebrandt, S., Yeung, C. K., Krause, M., & Offenhäusser, A. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00170-1 · Cited by 102
Anisotropic conduction in monolayers of neonatal rat heart cells cultured on collagen substrate.
Fast, V. G., & Kléber, A. G. (1994) · Circulation Research · doi:10.1161/01.res.75.3.591 · Cited by 95
Single-chip microelectronic system to interface with living cells
Heer, F., Hafizovic, S., Ugniwenko, T., Frey, U., Franks, W., Perriard, E. R., Perriard, J., Blau, A. W., Ziegler, C., & Hierlemann, A. R. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.10.003 · Cited by 88
Cohen, A., Shappir, J., Yitzchaik, S., & Spira, M. E. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.08.027 · Cited by 55
Yeung, C. K., Ingebrandt, S., Krause, M., Offenhäusser, A., & Knoll, W. (2001) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(01)00150-2 · Cited by 55
Banks, D., Balachandran, W., Richards, P. R., & Ewins, D. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/2/317 · Cited by 21 · cited 1×
“The latter 2 recording techniques use welldeveloped microfabrication methods to allow for direct multiplexed detection on a scale not possible with micropipette technology, although the MEAs and FETs exhibit limited signalto-noise ratios (S/N) and detection areas that make cellular and subcellular recording difficult…”
MethodMapping the sequence of contraction of the canine left ventricle
Augustijn, C. H., Arts, T. G. J., Prinzen, F. W., & Reneman, R. S. (1991) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00370800 · Cited by 16 · cited 2×
“Timing delays were calculated by using a standard cross-correlation technique (32, 33).”
Method
Cited by
Nanotechnological strategies for engineering complex tissues
Dvir, T., Timko, B. P., Kohane, D. S., & Langer, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.246 · Cited by 1,367
“or cultured separately on polymer films that were then brought into direct contact with nanowire array”
BackgroundSelf-citationNanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
“…the nanoscale size of the sensors that enabled its insertion into the cytosol through the plasma membrane of the cells, (b) the formation of GΩ resistance between the plasma membrane and the nanostructures, (c) the fact that the size of the sensing area does not affect its sensitivity 78,81,82 .”
Background25th Anniversary Article: Semiconductor Nanowires – Synthesis, Characterization, and Applications
Dasgupta, N. P., Sun, J., Liu, C., Brittman, S., Andrews, S. C., Lim, J., Gao, H., Yan, R., & Yang, P. (2014) · Advanced Materials · doi:10.1002/adma.201305929 · Cited by 880
Three-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes
Tian, B., Cohen-Karni, T., Qing, Q., Duan, X., Xie, P., & Lieber, C. M. (2010) · Science · doi:10.1126/science.1192033 · Cited by 798
Self-citation
Metadata
- Authors
- Cohen-Karni, T., Timko, B. P., Weiss, L. E., & Lieber, C. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2009-05-05
- Volume
- 106
- Issue
- 18
- Pages
- 7309-7313
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2077854881
- Cited by
- 218
- References
- 34
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.