Fast molecular tracking maps nanoscale dynamics of plasma membrane lipids
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
We describe an optical method capable of tracking a single fluorescent molecule with a flexible choice of high spatial accuracy (∼10–20 nm standard deviation or ∼20–40 nm full-width-at-half-maximum) and temporal resolution (< 1 ms). The fluorescence signal during individual passages of fluorescent molecules through a spot of excitation light allows the sequential localization and thus spatio-temporal tracking of the molecule if its fluorescence is collected on at least three separate point detectors arranged in close proximity. We show two-dimensional trajectories of individual, small organic dye labeled lipids diffusing in the plasma membrane of living cells and directly observe transient events of trapping on < 20 nm spatial scales. The trapping is cholesterol-assisted and much more pronounced for a sphingo- than for a phosphoglycero-lipid, with average trapping times of ∼15 ms and < 4 ms, respectively. The results support previous STED nanoscopy measurements and suggest that, at least for nontreated cells, the transient interaction of a single lipid is confined to macromolecular dimensions. Our experimental approach demonstrates that fast molecular movements can be tracked with minimal invasion, which can reveal new important details of cellular nano-organization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional rafts in cell membranes
Simons, K., & Ikonen, E. (1997) · Nature · doi:10.1038/42408 · Cited by 9,757
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Self-citationStructure and Function of Sphingolipid- and Cholesterol-rich Membrane Rafts
Brown, D. A., & London, E. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.r000005200 · Cited by 2,344
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320 · cited 1×
“A point-like object (molecule) emitting N photons may ideally be localized with an error Δx;Δy≈FWHM · N−1∕2, where FWHM is that of the detection PSF of the imaging system (35).”
BackgroundFluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Self-citationThermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy
Magde, D., Elson, E., & Webb, W. W. (1972) · Physical Review Letters · doi:10.1103/physrevlett.29.705 · Cited by 1,753
Direct observation of the nanoscale dynamics of membrane lipids in a living cell
Eggeling, C., Ringemann, C., Medda, R., Schwarzmann, G., Sandhoff, K., Polyakova, S., Belov, V. N., Hein, B., von Middendorff, C., Schönle, A., et al. (2009) · Nature · doi:10.1038/nature07596 · Cited by 1,520 · cited 10×
“These findings are in line with the observations of the previous STED-FCS measurements (23).”
BackgroundMethodResultSelf-citationMunro, S. (2003) · Cell · doi:10.1016/s0092-8674(03)00882-1 · Cited by 1,514
Rafts defined: a report on the Keystone symposium on lipid rafts and cell function
Pike, L. J. (2006) · Journal of Lipid Research · doi:10.1194/jlr.e600002-jlr200 · Cited by 1,500 · cited 1×
“Owing to the lack of suitable noninvasive techniques to detect these nanodomains in living cells, their spatial extent has been estimated at somewhere in the range of 5–200 nm (17), that is between molecular dimensions and the resolution limit of conventional fluorescence microscopy.”
BackgroundHigh-density mapping of single-molecule trajectories with photoactivated localization microscopy
Manley, S., Gillette, J. M., Patterson, G. H., Shroff, H., Hess, H. F., Betzig, E., & Lippincott-Schwartz, J. (2008) · Nature Methods · doi:10.1038/nmeth.1176 · Cited by 1,199
Cited by
Evidence for the Formation of Symmetric and Asymmetric DLPC-DAPC Lipid Bilayer Domains
Ritter, M., Schmidt, S., Jakab, M., Paulmichl, M., & Henderson, R. (2013) · Cellular Physiology and Biochemistry · doi:10.1159/000350122 · Cited by 3,923
Revitalizing membrane rafts: new tools and insights
Simons, K., & Gerl, M. J. (2010) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2977 · Cited by 1,234
Nanometer resolution imaging and tracking of fluorescent molecules with minimal photon fluxes
Balzarotti, F., Eilers, Y., Gwosch, K. C., Gynnå, A. H., Westphal, V., Stefani, F. D., Elf, J., & Hell, S. W. (2017) · Science · doi:10.1126/science.aak9913 · Cited by 1,225
Self-citationMembrane Organization and Lipid Rafts
Simons, K., & Sampaio, J. L. (2011) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a004697 · Cited by 1,064
Fluorescence nanoscopy in cell biology
Sahl, S. J., Hell, S. W., & Jakobs, S. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.71 · Cited by 990
Self-citationVisualizing and discovering cellular structures with super-resolution microscopy
Sigal, Y. M., Zhou, R., & Zhuang, X. (2018) · Science · doi:10.1126/science.aau1044 · Cited by 718
Kusumi, A., Fujiwara, T. K., Chadda, R., Xie, M., Tsunoyama, T. A., Kalay, Z., Kasai, R. S., & Suzuki, K. G. N. (2012) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev-cellbio-100809-151736 · Cited by 418
Stimulated Emission Depletion Microscopy
Blom, H., & Widengren, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00653 · Cited by 339
Tracking single molecules at work in living cells
Kusumi, A., Tsunoyama, T. A., Hirosawa, K. M., Kasai, R. S., & Fujiwara, T. K. (2014) · Nature Chemical Biology · doi:10.1038/nchembio.1558 · Cited by 332
Hierarchical mesoscale domain organization of the plasma membrane
Kusumi, A., Suzuki, K. G. N., Kasai, R. S., Ritchie, K., & Fujiwara, T. K. (2011) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2011.08.001 · Cited by 309
Schmidt, R., Weihs, T., Wurm, C. A., Jansen, I., Rehman, J., Sahl, S. J., & Hell, S. W. (2021) · Nature Communications · doi:10.1038/s41467-021-21652-z · Cited by 306
Self-citationHonigmann, A., Mueller, V., Ta, H., Schoenle, A., Sezgin, E., Hell, S. W., & Eggeling, C. (2014) · Nature Communications · doi:10.1038/ncomms6412 · Cited by 291
Self-citationJeon, J.-H., Javanainen, M., Martinez-Seara, H., Metzler, R., & Vattulainen, I. (2016) · Physical Review X · doi:10.1103/physrevx.6.021006 · Cited by 275
Transient GPI-anchored protein homodimers are units for raft organization and function
Suzuki, K. G. N., Kasai, R. S., Hirosawa, K. M., Nemoto, Y. L., Ishibashi, M., Miwa, Y., Fujiwara, T. K., & Kusumi, A. (2012) · Nature Chemical Biology · doi:10.1038/nchembio.1028 · Cited by 273
Single-molecule investigations of the stringent response machinery in living bacterial cells
English, B. P., Hauryliuk, V., Sanamrad, A., Tankov, S., Dekker, N. H., & Elf, J. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1102255108 · Cited by 267
Phase Separation in Lipid Membranes
Heberle, F. A., & Feigenson, G. W. (2011) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a004630 · Cited by 254
Mueller, V., Ringemann, C., Honigmann, A., Schwarzmann, G., Medda, R., Leutenegger, M., Polyakova, S., Belov, V. N., Hell, S. W., & Eggeling, C. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.09.006 · Cited by 253
Self-citationRaft-based interactions of gangliosides with a GPI-anchored receptor
Komura, N., Suzuki, K. G. N., Ando, H., Konishi, M., Koikeda, M., Imamura, A., Chadda, R., Fujiwara, T. K., Tsuboi, H., Sheng, R., et al. (2016) · Nature Chemical Biology · doi:10.1038/nchembio.2059 · Cited by 191
‘MINFLUX monitors rapid molecular jumps with superior spatiotemporal resolution’
Eilers, Y., Ta, H., Gwosch, K. C., Balzarotti, F., & Hell, S. W. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1801672115 · Cited by 188
“The need for large photon detection numbers N has spurred the development of related methods, such as confocalized tracking with multiple point detectors (16, 17), detection PSF engineering (18), Gaussian beam scanning schemes (i.”
Self-citationCell cholesterol homeostasis: Mediation by active cholesterol
Steck, T. L., & Lange, Y. (2010) · Trends in Cell Biology · doi:10.1016/j.tcb.2010.08.007 · Cited by 139
Metadata
- Authors
- Sahl, S. J., Leutenegger, M., Hilbert, M., Hell, S. W., & Eggeling, C.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-03-29
- Volume
- 107
- Issue
- 15
- Pages
- 6829-6834
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1975014786
- Cited by
- 187
- References
- 40
- FWCI
- 12.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.