Real-time label-free monitoring of adipose-derived stem cell differentiation with electric cell-substrate impedance sensing
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Real-time monitoring of stem cells (SCs) differentiation will be critical to scale-up SC technologies, while label-free techniques will be desirable to quality-control SCs without precluding their therapeutic potential. We cultured adipose-derived stem cells (ADSCs) on top of multielectrode arrays and measured variations in the complex impedance Z* throughout induction of ADSCs toward osteoblasts and adipocytes. Z* was measured up to 17 d, every 180 s, over a 62.5–64kHz frequency range with an ECIS Zθ instrument. We found that osteogenesis and adipogenesis were characterized by distinct Z* time-courses. Significant differences were found ( P = 0.007) as soon as 12 h post induction. An increase in the barrier resistance (Rb) up to 1.7 ohm·cm 2 was associated with early osteo-induction, whereas Rb peaked at 0.63 ohm·cm 2 for adipo-induced cells before falling to zero at t = 129 h. Dissimilarities in Z* throughout early induction (<24 h) were essentially attributed to variations in the cell-substrate parameter α. Four days after induction, cell membrane capacitance (Cm) of osteo-induced cells (Cm = 1.72 ± 0.10 μF/cm 2 ) was significantly different from that of adipo-induced cells (Cm = 2.25 ± 0.27 μF/cm 2 ), indicating that Cm could be used as an early marker of differentiation. Finally, we demonstrated long-term monitoring and measured a shift in the complex plane in the middle frequency range (1 kHz to 8 kHz) between early ( t = 100 h) and late induction ( t = 380 h). This study demonstrated that the osteoblast and adipocyte lineages have distinct dielectric properties and that such differences can be used to perform real-time label-free quantitative monitoring of adult stem cell differentiation with impedance sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilineage Cells from Human Adipose Tissue: Implications for Cell-Based Therapies
Zuk, P. A., Zhu, M., Mizuno, H., Huang, J., Futrell, J. W., Katz, A. J., Benhaim, P., Lorenz, H. P., & Hedrick, M. H. (2001) · Tissue Engineering · doi:10.1089/107632701300062859 · Cited by 7,956 · cited 1×
“Among them, adipose-derived stem cells (ADSCs) are adult stem cells isolated at high concentration from lipoaspirates (1, 2).”
BackgroundHuman Adipose Tissue Is a Source of Multipotent Stem Cells
Zuk, P. A., Zhu, M., Ashjian, P., De Ugarte, D. A., Huang, J. I., Mizuno, H., Alfonso, Z. C., Fraser, J. K., Benhaim, P., & Hedrick, M. H. (2002) · Molecular Biology of the Cell · doi:10.1091/mbc.e02-02-0105 · Cited by 6,664 · cited 2×
“Among them, adipose-derived stem cells (ADSCs) are adult stem cells isolated at high concentration from lipoaspirates (1, 2).”
BackgroundResultMicromotion of mammalian cells measured electrically.
Giaever, I., & Keese, C. R. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.17.7896 · Cited by 828 · cited 7×
“The frequency-dependent complex impedance, Z(t,f), was broken down in three parameters with the model developed by Giaever and Keese (6, 9).”
BackgroundMethodInfluentialA morphological biosensor for mammalian cells
Giaever, I., & Keese, C. R. (1993) · Nature · doi:10.1038/366591a0 · Cited by 770
Wegener, J., Keese, C. R., & Giaever, I. (2000) · Experimental Cell Research · doi:10.1006/excr.2000.4919 · Cited by 769 · cited 1×
“This technique has found many applications in cell biology, for example, in the study of cell proliferation and spreading (11, 12), wound healing (13), cancer cell lines (14–16), and cytotoxicity (17–23).”
MethodMonitoring fibroblast behavior in tissue culture with an applied electric field.
Giaever, I., & Keese, C. R. (1984) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.81.12.3761 · Cited by 608
Impedance spectroscopy flow cytometry: On‐chip label‐free cell differentiation
Cheung, K. C., Gawad, S., & Renaud, P. (2005) · Cytometry Part A · doi:10.1002/cyto.a.20141 · Cited by 484
Liu, T. M., Martina, M., Hutmacher, D. W., Hui, J. H. P., Lee, E. H., & Lim, B. (2007) · Stem Cells · doi:10.1634/stemcells.2006-0394 · Cited by 428
Electrical wound-healing assay for cells in vitro
Keese, C. R., Wegener, J., Walker, S. R., & Giaever, I. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0307588100 · Cited by 421 · cited 1×
“This technique has found many applications in cell biology, for example, in the study of cell proliferation and spreading (11, 12), wound healing (13), cancer cell lines (14–16), and cytotoxicity (17–23).”
MethodLeukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry
Holmes, D., Pettigrew, D., Reccius, C. H., Gwyer, J. D., van Berkel, C., Holloway, J., Davies, D. E., & Morgan, H. (2009) · Lab on a Chip · doi:10.1039/b910053a · Cited by 408
Research works printed but not linked: 8
- 10.1103/PhysRevE.76.041908 · doi:10.1103/physreve.76.041908
- 10.1016/j.bios.2008.09.033 · doi:10.1016/j.bios.2008.09.033
- 10.1021/bp025733x · doi:10.1021/bp025733x
- 10.1016/j.taap.2004.10.025 · doi:10.1016/j.taap.2004.10.025
- M Stephens, MS Talary, R Pethig, AK Burnett, KI Mills, The dielectrophoresis enrichment of CD34+ cells from peripheral blood stem cell harvests. Bone Marrow Transplant 18, 777–782 (1996).
- 10.1109/84.749402 · doi:10.1109/84.749402
- KI Mills, M Stephens, M Talary, R Pethig, AK Burnett, Dielectrophoretic separation of CD34-positive cells from peripheral stem cell harvests. Blood 86, 462 (1995).
- 10.1103/PhysRevE.74.041908 · doi:10.1103/physreve.74.041908
Cited by
A review of impedance measurements of whole cells
Xu, Y., Xie, X., Duan, Y., Wang, L., Cheng, Z., & Cheng, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.027 · Cited by 424
Peng, Z., Pati, S., Potter, D., Brown, R., Holcomb, J. B., Grill, R., Wataha, K., Park, P. W., Xue, H., & Kozar, R. A. (2013) · Shock · doi:10.1097/shk.0b013e31829f91fc · Cited by 211
“Electric cell-substrate impedance sensing can assess barrier function over time with measurements being performed directly in the cell culture medium (12).”
BackgroundHeileman, K., Daoud, J., & Tabrizian, M. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.04.017 · Cited by 202
Continuous-flow sorting of stem cells and differentiation products based on dielectrophoresis
Song, H., Rosano, J. M., Wang, Y., Garson, C. J., Prabhakarpandian, B., Pant, K., Klarmann, G. J., Perantoni, A., Alvarez, L. M., & Lai, E. (2015) · Lab on a Chip · doi:10.1039/c4lc01253d · Cited by 175
Engel, N., Dau, M., Engel, V., Franz, D., Klemmstein, F., Thanisch, C., Kolb, J. F., Frank, M., Springer, A., Köhling, R., et al. (2023) · Biomedicines · doi:10.3390/biomedicines11030697 · Cited by 10
Zemmyo, D., & Miyata, S. (2019) · Micromachines · doi:10.3390/mi10070455 · Cited by 7
“Several reports have been published regarding the monitoring of electrical characteristics during lipid accumulation in adipocytes [14,15].”
BackgroundMicroalgae Lipids Detection and Quantification Method Towards Online Real-Time Monitoring: A Review
Chong, K. L., & Ahmad, M. R. (2023) · ELEKTRIKA- Journal of Electrical Engineering · doi:10.11113/elektrika.v22n3.454 · Cited by 2
“However, studies have reported that the changes in impedance at lower frequencies (10-500KHz) due to lipid accumulation were ignorable [62], [63] while impedance at higher frequencies (1–15 MHz) is observable in response to lipid accumulation [64].”
Background
Metadata
- Authors
- Bagnaninchi, P. O., & Drummond, N.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-04-04
- Volume
- 108
- Issue
- 16
- Pages
- 6462-6467
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2108309439
- Cited by
- 226
- References
- 34
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.