Real-time label-free monitoring of adipose-derived stem cell differentiation with electric cell-substrate impedance sensing
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Real-time monitoring of stem cells (SCs) differentiation will be critical to scale-up SC technologies, while label-free techniques will be desirable to quality-control SCs without precluding their therapeutic potential. We cultured adipose-derived stem cells (ADSCs) on top of multielectrode arrays and measured variations in the complex impedance Z* throughout induction of ADSCs toward osteoblasts and adipocytes. Z* was measured up to 17 d, every 180 s, over a 62.5–64kHz frequency range with an ECIS Zθ instrument. We found that osteogenesis and adipogenesis were characterized by distinct Z* time-courses. Significant differences were found ( P = 0.007) as soon as 12 h post induction. An increase in the barrier resistance (Rb) up to 1.7 ohm·cm 2 was associated with early osteo-induction, whereas Rb peaked at 0.63 ohm·cm 2 for adipo-induced cells before falling to zero at t = 129 h. Dissimilarities in Z* throughout early induction (<24 h) were essentially attributed to variations in the cell-substrate parameter α. Four days after induction, cell membrane capacitance (Cm) of osteo-induced cells (Cm = 1.72 ± 0.10 μF/cm 2 ) was significantly different from that of adipo-induced cells (Cm = 2.25 ± 0.27 μF/cm 2 ), indicating that Cm could be used as an early marker of differentiation. Finally, we demonstrated long-term monitoring and measured a shift in the complex plane in the middle frequency range (1 kHz to 8 kHz) between early ( t = 100 h) and late induction ( t = 380 h). This study demonstrated that the osteoblast and adipocyte lineages have distinct dielectric properties and that such differences can be used to perform real-time label-free quantitative monitoring of adult stem cell differentiation with impedance sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilineage Cells from Human Adipose Tissue: Implications for Cell-Based Therapies
Zuk, P. A., Zhu, M., Mizuno, H., Huang, J., Futrell, J. W., Katz, A. J., Benhaim, P., Lorenz, H. P., & Hedrick, M. H. (2001) · Tissue Engineering · doi:10.1089/107632701300062859 · Cited by 7,956 · cited 1×
“Among them, adipose-derived stem cells (ADSCs) are adult stem cells isolated at high concentration from lipoaspirates (1, 2).”
BackgroundHuman Adipose Tissue Is a Source of Multipotent Stem Cells
Zuk, P. A., Zhu, M., Ashjian, P., De Ugarte, D. A., Huang, J. I., Mizuno, H., Alfonso, Z. C., Fraser, J. K., Benhaim, P., & Hedrick, M. H. (2002) · Molecular Biology of the Cell · doi:10.1091/mbc.e02-02-0105 · Cited by 6,664 · cited 2×
“Among them, adipose-derived stem cells (ADSCs) are adult stem cells isolated at high concentration from lipoaspirates (1, 2).”
BackgroundResultMicromotion of mammalian cells measured electrically.
Giaever, I., & Keese, C. R. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.17.7896 · Cited by 828 · cited 7×
“The frequency-dependent complex impedance, Z(t,f), was broken down in three parameters with the model developed by Giaever and Keese (6, 9).”
BackgroundMethodInfluentialA morphological biosensor for mammalian cells
Giaever, I., & Keese, C. R. (1993) · Nature · doi:10.1038/366591a0 · Cited by 770
Wegener, J., Keese, C. R., & Giaever, I. (2000) · Experimental Cell Research · doi:10.1006/excr.2000.4919 · Cited by 769 · cited 1×
“This technique has found many applications in cell biology, for example, in the study of cell proliferation and spreading (11, 12), wound healing (13), cancer cell lines (14–16), and cytotoxicity (17–23).”
MethodMonitoring fibroblast behavior in tissue culture with an applied electric field.
Giaever, I., & Keese, C. R. (1984) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.81.12.3761 · Cited by 608
Impedance spectroscopy flow cytometry: On‐chip label‐free cell differentiation
Cheung, K. C., Gawad, S., & Renaud, P. (2005) · Cytometry Part A · doi:10.1002/cyto.a.20141 · Cited by 484
Liu, T. M., Martina, M., Hutmacher, D. W., Hui, J. H. P., Lee, E. H., & Lim, B. (2007) · Stem Cells · doi:10.1634/stemcells.2006-0394 · Cited by 428
Electrical wound-healing assay for cells in vitro
Keese, C. R., Wegener, J., Walker, S. R., & Giaever, I. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0307588100 · Cited by 421 · cited 1×
“This technique has found many applications in cell biology, for example, in the study of cell proliferation and spreading (11, 12), wound healing (13), cancer cell lines (14–16), and cytotoxicity (17–23).”
MethodLeukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry
Holmes, D., Pettigrew, D., Reccius, C. H., Gwyer, J. D., van Berkel, C., Holloway, J., Davies, D. E., & Morgan, H. (2009) · Lab on a Chip · doi:10.1039/b910053a · Cited by 408
The Adipose-derived Stem Cell: Looking Back and Looking Ahead
Zuk, P. A. (2010) · Molecular Biology of the Cell · doi:10.1091/mbc.e09-07-0589 · Cited by 350 · cited 1×
“They are a realistic autologous source for orthopedic and reconstructive surgery applications (3) and to develop patientspecific in vitro models for drug screening.”
BackgroundAdipocyte differentiation of multipotent cells established from human adipose tissue
Rodriguez, A.-M., Elabd, C., Delteil, F., Astier, J., Vernochet, C., Saint-Marc, P., Guesnet, J., Guezennec, A., Amri, E.-Z., Dani, C., et al. (2004) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2004.01.053 · Cited by 292
Use of Electric Fields to Monitor the Dynamical Aspect of Cell Behavior in Tissue Culture
Giaever, I., & Keese, C. R. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325896 · Cited by 275
Impedance analysis of MDCK cells measured by electric cell-substrate impedance sensing
Lo, C. M., Keese, C. R., & Giaever, I. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80153-0 · Cited by 272 · cited 8×
“Cell dielectric properties could be modeled from the impedance spectrum in different ways with basal, apical, and lateral cell membrane capacitance (9), equivalent circuit model (39), or through a mean field model (40).”
BackgroundMethodInfluentialDielectric properties of mouse lymphocytes and erythrocytes
Asami, K., Takahashi, Y., & Takashima, S. (1989) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/0167-4889(89)90183-3 · Cited by 224 · cited 1×
“Ideally, a double shell model should be considered, which takes into account the dielectric properties of the nucleus, the cytoplasm, and the cytoplasmic membrane (41).”
BackgroundUnique Dielectric Properties Distinguish Stem Cells and Their Differentiated Progeny
Flanagan, L. A., Lu, J., Wang, L., Marchenko, S. A., Jeon, N. L., Lee, A. P., & Monuki, E. S. (2008) · Stem Cells · doi:10.1634/stemcells.2007-0810 · Cited by 207 · cited 3×
“In the same study, dielectric properties of NSPCs in suspension have been found to discriminate stem cell progeny before the apparition of specific cell surface proteins (24).”
BackgroundInfluentialReal-Time Impedance Assay to Follow the Invasive Activities of Metastatic Cells in Culture
Keese, C. R., Bhawe, K. M., Wegener, J., & Giæver, I. (2002) · BioTechniques · doi:10.2144/02334rr01 · Cited by 168
Xiao, C., Lachance, B., Sunahara, G., & Luong, J. H. T. (2002) · Analytical Chemistry · doi:10.1021/ac025848f · Cited by 168
Vykoukal, J. V., Vykoukal, D. M., Freyberg, S., Alt, E., & Gascoyne, P. R. C. (2008) · Lab on a Chip · doi:10.1039/b717043b · Cited by 165
Male, K. B., Lachance, B., Hrapovic, S., Sunahara, G., & Luong, J. H. T. (2008) · Analytical Chemistry · doi:10.1021/ac8004555 · Cited by 164
Monitoring Motion of Confluent Cells in Tissue Culture
Lo, C., Keese, C. R., & Giæver, I. (1993) · Experimental Cell Research · doi:10.1006/excr.1993.1014 · Cited by 161
Dielectrophoresis: A Review of Applications for Stem Cell Research
Pethig, R., Menachery, A., Pells, S., & Sousa, P. A. D. (2010) · BioMed Research International · doi:10.1155/2010/182581 · Cited by 154
Impedance analysis of epithelial and endothelial cell monolayers cultured on gold surfaces
Wegener, J., Sieber, M., & Galla, H. (1996) · Journal of Biochemical and Biophysical Methods · doi:10.1016/0165-022x(96)00005-x · Cited by 151 · cited 1×
“Cell dielectric properties could be modeled from the impedance spectrum in different ways with basal, apical, and lateral cell membrane capacitance (9), equivalent circuit model (39), or through a mean field model (40).”
BackgroundLo, C., Keese, C. R., & Giæver, I. (1999) · Experimental Cell Research · doi:10.1006/excr.1999.4538 · Cited by 131 · cited 2×
“Typical reported values (10) for α are 18 Ω.”
BackgroundMitra, P., Keese, C. R., & Giæver, I. (1991) · PubMed · Cited by 128
Cytotoxicity of Metal and Semiconductor Nanoparticles Indicated by Cellular Micromotility
Tarantola, M., Schneider, D., Sunnick, E., Adam, H., Pierrat, S., Rosman, C., Breus, V. V., Sönnichsen, C., Basché, T., Wegener, J., et al. (2008) · ACS Nano · doi:10.1021/nn800721j · Cited by 126
Use of electric cell–substrate impedance sensing to assess in vitro cytotoxicity
Opp, D., Wafula, B., Lim, J., Huang, E., Lo, J.-C., & Lo, C.-M. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.01.015 · Cited by 125
Elabd, C., Chiellini, C., Massoudi, A., Cochet, O., Zaragosi, L., Trojani, C., Michiels, J., Weiss, P., Carle, G. F., Rochet, N., et al. (2007) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2007.06.180 · Cited by 74
Garcia, T., Roman‐Roman, S., Jackson, A. M., Theilhaber, J., Connolly, T., Spinella-Jaegle, S., Kawai, S., Courtois, B., Bushnell, S., Auberval, M., et al. (2002) · Bone · doi:10.1016/s8756-3282(02)00781-0 · Cited by 73 · cited 1×
“Similarly genome-wide analysis of genes up-regulated during osteogenesis and adipogenesis demonstrated the apparition of specific markers 2 d after induction (36).”
BackgroundDynamics of human cancer cell lines monitored by electrical and acoustic fluctuation analysis
Tarantola, M., Marel, A., Sunnick, E., Adam, H., Wegener, J., & Janshoff, A. (2010) · Integrative Biology · doi:10.1039/b920815a · Cited by 70
Impedance analysis of fibroblastic cell layers measured by electric cell-substrate impedance sensing
Lo, C., & Ferrier, J. (1998) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.57.6982 · Cited by 70 · cited 1×
“For an homogeneous cell layer, cell-tosubstrate distance could be computed directly from α and cell radius or cell width (fibroblastic cells) (37).”
MethodOn-line monitoring of lipid storage in yeasts using impedance spectroscopy
Maskow, T., Röllich, A., Fetzer, I., Ackermann, J., & Harms, H. (2008) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2008.02.014 · Cited by 49 · cited 1×
“Indeed, a clear contribution of inclusions containing sparse moving ions such as lipid droplets should be expected in the 1–10 MHz range (42).”
BackgroundHatakeyama, N., Kojima, T., Iba, K., Murata, M., Thi, M. M., Spray, D. C., Osanai, M., Chiba, H., Ishiai, S., Yamashita, T., et al. (2008) · Cell and Tissue Research · doi:10.1007/s00441-008-0690-9 · Cited by 36 · cited 1×
“cm(2) is reported (38) for osteoblast-like MC3T3 cells, which can be compared with TER values of 136 Ω.”
BackgroundBagnaninchi, P., Dikeakos, M., Veres, T., & Tabrizian, M. (2004) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2004.837901 · Cited by 31
Self-citation
Research works printed but not linked: 8
- 10.1103/PhysRevE.76.041908 · doi:10.1103/physreve.76.041908
- 10.1016/j.bios.2008.09.033 · doi:10.1016/j.bios.2008.09.033
- 10.1021/bp025733x · doi:10.1021/bp025733x
- 10.1016/j.taap.2004.10.025 · doi:10.1016/j.taap.2004.10.025
- M Stephens, MS Talary, R Pethig, AK Burnett, KI Mills, The dielectrophoresis enrichment of CD34+ cells from peripheral blood stem cell harvests. Bone Marrow Transplant 18, 777–782 (1996).
- 10.1109/84.749402 · doi:10.1109/84.749402
- KI Mills, M Stephens, M Talary, R Pethig, AK Burnett, Dielectrophoretic separation of CD34-positive cells from peripheral stem cell harvests. Blood 86, 462 (1995).
- 10.1103/PhysRevE.74.041908 · doi:10.1103/physreve.74.041908
Cited by
A review of impedance measurements of whole cells
Xu, Y., Xie, X., Duan, Y., Wang, L., Cheng, Z., & Cheng, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.027 · Cited by 424
Peng, Z., Pati, S., Potter, D., Brown, R., Holcomb, J. B., Grill, R., Wataha, K., Park, P. W., Xue, H., & Kozar, R. A. (2013) · Shock · doi:10.1097/shk.0b013e31829f91fc · Cited by 211
“Electric cell-substrate impedance sensing can assess barrier function over time with measurements being performed directly in the cell culture medium (12).”
BackgroundHeileman, K., Daoud, J., & Tabrizian, M. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.04.017 · Cited by 202
Continuous-flow sorting of stem cells and differentiation products based on dielectrophoresis
Song, H., Rosano, J. M., Wang, Y., Garson, C. J., Prabhakarpandian, B., Pant, K., Klarmann, G. J., Perantoni, A., Alvarez, L. M., & Lai, E. (2015) · Lab on a Chip · doi:10.1039/c4lc01253d · Cited by 175
Engel, N., Dau, M., Engel, V., Franz, D., Klemmstein, F., Thanisch, C., Kolb, J. F., Frank, M., Springer, A., Köhling, R., et al. (2023) · Biomedicines · doi:10.3390/biomedicines11030697 · Cited by 10
Metadata
- Authors
- Bagnaninchi, P. O., & Drummond, N.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-04-04
- Volume
- 108
- Issue
- 16
- Pages
- 6462-6467
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2108309439
- Cited by
- 226
- References
- 34
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.