Micro-chemical synthesis of molecular probes on an electronic microfluidic device
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
We have developed an all-electronic digital microfluidic device for microscale chemical synthesis in organic solvents, operated by electrowetting-on-dielectric (EWOD). As an example of the principles, we demonstrate the multistep synthesis of [ 18 F]FDG, the most common radiotracer for positron emission tomography (PET), with high and reliable radio-fluorination efficiency of [ 18 F]FTAG (88 ± 7%, n = 11) and quantitative hydrolysis to [ 18 F]FDG (> 95%, n = 11). We furthermore show that batches of purified [ 18 F]FDG can successfully be used for PET imaging in mice and that they pass typical quality control requirements for human use (including radiochemical purity, residual solvents, Kryptofix, chemical purity, and pH). We report statistical repeatability of the radiosynthesis rather than best-case results, demonstrating the robustness of the EWOD microfluidic platform. Exhibiting high compatibility with organic solvents and the ability to carry out sophisticated actuation and sensing of reaction droplets, EWOD is a unique platform for performing diverse microscale chemical syntheses in small volumes, including multistep processes with intermediate solvent-exchange steps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643 · cited 1×
“Because the primary material used for these latter devices, poly(dimehtylsiloxane) (PDMS), is known to be incompatible with many organic solvents and to absorb or interact with many reagents (7), this platform is inherently limited in its chemical flexibility.”
BackgroundReactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598 · cited 1×
“Droplets are sandwiched into a disc shape between the plates, and electrical potential is applied to individual or multiple electrodes to achieve unit operations such as droplet generation, transport, splitting, and merging (9).”
BackgroundSelf-citationHamacher, K., Coenen, H. H., & Stöcklin, G. (1986) · PubMed · Cited by 1,351
Positron emission tomography provides molecular imaging of biological processes
Phelps, M. E. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.16.9226 · Cited by 1,229
Self-citationDigital microfluidics: is a true lab-on-a-chip possible?
Fair, R. B. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0161-8 · Cited by 1,063
AMIDE: A Free Software Tool for Multimodality Medical Image Analysis
Loening, A. M., & Gambhir, S. S. (2003) · Molecular Imaging · doi:10.1162/15353500200303133 · Cited by 1,018
Synthesis of 11C, 18F, 15O, and 13N Radiolabels for Positron Emission Tomography
Miller, P. W., Long, N. J., Vilar, R., & Gee, A. D. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200800222 · Cited by 894 · cited 1×
“0 mL), that changing from macroscale to microscale geometry leads to dramatic acceleration of reactions in the synthesis of 1⁄218F FDG (17, 18) and other PET tracers labeled with short-lived radioisotopes (19).”
BackgroundProgress and Promise of FDG-PET Imaging for Cancer Patient Management and Oncologic Drug Development
Kelloff, G. J., Hoffman, J. M., Johnson, B., Scher, H. I., Siegel, B. A., Cheng, E. Y., Cheson, B. D., O'Shaughnessy, J., Guyton, K. Z., Mankoff, D. A., et al. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-2626 · Cited by 671 · cited 1×
“the most commonly used radiotracer for imaging of living subjects with positron emission tomography (PET) (15, 16).”
MethodMultistep Synthesis of a Radiolabeled Imaging Probe Using Integrated Microfluidics
Lee, C.-C., Sui, G., Elizarov, A., Shu, C. J., Shin, Y.-S., Dooley, A. N., Huang, J., Daridon, A., Wyatt, P., Stout, D., et al. (2005) · Science · doi:10.1126/science.1118919 · Cited by 510
Self-citationGeyer, K., Codée, J. D. C., & Seeberger, P. H. (2006) · Chemistry – A European Journal · doi:10.1002/chem.200600596 · Cited by 462 · cited 1×
“T use of micro-reaction technology in chemistry has grown tremendously over the past several years (1), due primarily to the highly precise control of reaction conditions that is possible through rapid mixing and heat transport, leading to improved reaction speeds and selectivity compared to macroscale approaches (2).”
BackgroundMultistep Continuous‐Flow Microchemical Synthesis Involving Multiple Reactions and Separations
Sahoo, H. R., Kralj, J. G., & Jensen, K. F. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200701434 · Cited by 397 · cited 1×
“Continuous liquid-liquid extraction and other processes have been developed to enable multistep reactions where different solvents are required in different steps (4).”
BackgroundIntegrated Microreactors for Reaction Automation: New Approaches to Reaction Development
McMullen, J. P., & Jensen, K. F. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073718 · Cited by 359 · cited 1×
“T use of micro-reaction technology in chemistry has grown tremendously over the past several years (1), due primarily to the highly precise control of reaction conditions that is possible through rapid mixing and heat transport, leading to improved reaction speeds and selectivity compared to macroscale approaches (2).”
BackgroundGong, J., & Kim, C.-J. “. (2008) · Lab on a Chip · doi:10.1039/b717417a · Cited by 258 · cited 1×
“It is possible to integrate additional electronically controlled functions into the chip such as sensors to monitor liquid volumes (10) and composition (11) as well as heaters and temperature sensors for heating liquid droplets or evaporating solvent (12).”
BackgroundSelf-citationReview of 18F-FDG synthesis and quality control
Yu, S. (2006) · Biomedical Imaging and Intervention Journal · doi:10.2349/biij.2.4.e57 · Cited by 155
Microreactors for radiopharmaceutical synthesis
Elizarov, A. M. (2009) · Lab on a Chip · doi:10.1039/b820299k · Cited by 127
Cho, J. S., Taschereau, R., Olma, S., Liu, K., Chen, Y., Shen, C., van Dam, R. M., & Chatziioannou, A. F. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/22/001 · Cited by 110 · cited 1×
“Compared to the previously reported Cerenkov imaging system (30), the setup here used a rotatable mirror to switch between Cerenkov and bright-field imaging subsystems, enabling optimization of each imaging modality and permitting the Cerenkov CCD camera to be shielded from direct gamma irradiation to reduce noise in…”
MethodSelf-citationNelson, W. C., Peng, I. X., Lee, G. A., Loo, J. A., Garrell, R. L., & Kim, C. (2010) · Analytical Chemistry · doi:10.1021/ac101833b · Cited by 91 · cited 2×
“It is possible to integrate additional electronically controlled functions into the chip such as sensors to monitor liquid volumes (10) and composition (11) as well as heaters and temperature sensors for heating liquid droplets or evaporating solvent (12).”
BackgroundSelf-citationSchertzer, M. J., Ben-Mrad, R., & Sullivan, P. E. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.12.019 · Cited by 69 · cited 1×
“It is possible to integrate additional electronically controlled functions into the chip such as sensors to monitor liquid volumes (10) and composition (11) as well as heaters and temperature sensors for heating liquid droplets or evaporating solvent (12).”
Background
Cited by
Choi, K., Ng, A. H. C., Fobel, R., & Wheeler, A. R. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143028 · Cited by 817
A review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
Magnetic digital microfluidics – a review
Zhang, Y., & Nguyen, N.-T. (2017) · Lab on a Chip · doi:10.1039/c7lc00025a · Cited by 364
Digital microfluidics: a versatile tool for applications in chemistry, biology and medicine
Jebrail, M. J., Bartsch, M. S., & Patel, K. D. (2012) · Lab on a Chip · doi:10.1039/c2lc40318h · Cited by 324
Photo-actuation of liquids for light-driven microfluidics: state of the art and perspectives
Baigl, D. (2012) · Lab on a Chip · doi:10.1039/c2lc40596b · Cited by 253
Metadata
- Authors
- Keng, P. Y., Chen, S., Ding, H., Sadeghi, S., Shah, G. J., Dooraghi, A., Phelps, M. E., Satyamurthy, N., Chatziioannou, A. F., Kim, C.-J. “., & van Dam, R. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-12-30
- Volume
- 109
- Issue
- 3
- Pages
- 690-695
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2141430374
- Cited by
- 180
- References
- 19
- FWCI
- 12.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.