Volta potential phase plate for in-focus phase contrast transmission electron microscopy
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Significance: Biological electron cryomicroscopy is limited by the radiation sensitivity of the samples and the consequent need to minimize exposure to the beam. This, in turn, results in low-contrast images with a poor signal-to-noise ratio. The current practice to improve phase contrast by defocusing results in contrast transfer functions necessitating image restoration to provide interpretable data. Phase plates enable in-focus phase contrast, but the existing ones, including the thin film Zernike-type phase plate, suffer from severe limitations, such as a short usable life span, fringing artifacts, and problems in using them in automated data acquisition procedures. The Volta phase plate presented here solves those problems and has the potential to become a practical solution for in-focus phase contrast in transmission electron microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Work Functions and Surface Functional Groups of Multiwall Carbon Nanotubes
Ago, H., Kugler, T., Cacialli, F., Salaneck, W. R., Shaffer, M. S. P., Windle, A. H., & Friend, R. H. (1999) · The Journal of Physical Chemistry B · doi:10.1021/jp991659y · Cited by 969
Kumar, P. V., Bernardi, M., & Grossman, J. C. (2013) · ACS Nano · doi:10.1021/nn305507p · Cited by 287
Transmission electron microscopy with Zernike phase plate
Danev, R., & Nagayama, K. (2001) · Ultramicroscopy · doi:10.1016/s0304-3991(01)00088-2 · Cited by 281
Self-citationInvited Review Article: Methods for imaging weak-phase objects in electron microscopy
Glaeser, R. M. (2013) · Review of Scientific Instruments · doi:10.1063/1.4830355 · Cited by 146
Visualizing virus assembly intermediates inside marine cyanobacteria
Dai, W., Fu, C., Raytcheva, D., Flanagan, J. M., Khant, H. A., Liu, X., Rochat, R. H., Haase‐Pettingell, C., Piret, J., Ludtke, S. J., et al. (2013) · Nature · doi:10.1038/nature12604 · Cited by 140
Murata, K., Liu, X., Danev, R., Jakana, J., Schmid, M. F., King, J., Nagayama, K., & Chiu, W. (2010) · Structure · doi:10.1016/j.str.2010.06.006 · Cited by 128
Self-citationConvenient contrast enhancement by a hole-free phase plate
Malac, M., Beleggia, M., Kawasaki, M., Li, P., & Egerton, R. F. (2012) · Ultramicroscopy · doi:10.1016/j.ultramic.2012.02.004 · Cited by 83
Design of an electron microscope phase plate using a focused continuous-wave laser
Müller, H., Jin, J., Danev, R., Spence, J. C. H., Padmore, H. A., & Glaeser, R. M. (2010) · New Journal of Physics · doi:10.1088/1367-2630/12/7/073011 · Cited by 78
Self-citationNagayama, K., & Danev, R. (2008) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2008.2268 · Cited by 69
Self-citationPhase Plates for Transmission Electron Microscopy
Danev, R., & Nagayama, K. (2010) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(10)81014-6 · Cited by 63
Self-citation
Cited by
CTFFIND4: Fast and accurate defocus estimation from electron micrographs
Rohou, A., & Grigorieff, N. (2015) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.08.008 · Cited by 4,913
Guillén-Boixet, J., Kopach, A., Holehouse, A. S., Wittmann, S., Jahnel, M., Schlüßler, R., Kim, K., Trussina, I. R. E. A., Wang, J., Mateju, D., et al. (2020) · Cell · doi:10.1016/j.cell.2020.03.049 · Cited by 865
Zivanov, J., Nakane, T., & Scheres, S. H. W. (2020) · IUCrJ · doi:10.1107/s2052252520000081 · Cited by 781
Visualizing the molecular sociology at the HeLa cell nuclear periphery
Mahamid, J., Pfeffer, S., Schaffer, M., Villa, E., Danev, R., Kuhn Cuellar, L., Förster, F., Hyman, A. A., Plitzko, J. M., & Baumeister, W. (2016) · Science · doi:10.1126/science.aad8857 · Cited by 576
Self-citationProtein condensates as aging Maxwell fluids
Jawerth, L., Fischer-Friedrich, E., Saha, S., Wang, J., Franzmann, T., Zhang, X., Sachweh, J., Ruer, M., Ijavi, M., Saha, S., et al. (2020) · Science · doi:10.1126/science.aaw4951 · Cited by 572
Cryo-EM in drug discovery: achievements, limitations and prospects
Renaud, J.-P., Chari, A., Ciferri, C., Liu, W.-T., Rémigy, H.-W., Stark, H., & Wiesmann, C. (2018) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2018.77 · Cited by 461
Single-particle cryo-EM—How did it get here and where will it go
Cheng, Y. (2018) · Science · doi:10.1126/science.aat4346 · Cited by 448
Cryo-EM: A Unique Tool for the Visualization of Macromolecular Complexity
Nogales, E., & Scheres, S. H. W. (2015) · Molecular Cell · doi:10.1016/j.molcel.2015.02.019 · Cited by 378
In Situ Architecture and Cellular Interactions of PolyQ Inclusions
Bäuerlein, F. J. B., Saha, I., Mishra, A., Kalemanov, M., Martínez-Sánchez, A., Klein, R., Dudanova, I., Hipp, M. S., Hartl, F. U., Baumeister, W., et al. (2017) · Cell · doi:10.1016/j.cell.2017.08.009 · Cited by 349
Self-citationThe promise and the challenges of cryo‐electron tomography
Turk, M., & Baumeister, W. (2020) · FEBS Letters · doi:10.1002/1873-3468.13948 · Cited by 333
Self-citationProphage-triggered membrane vesicle formation through peptidoglycan damage in Bacillus subtilis
Toyofuku, M., Cárcamo-Oyarce, G., Yamamoto, T., Eisenstein, F., Hsiao, C.-C., Kurosawa, M., Gademann, K., Pilhofer, M., Nomura, N., & Eberl, L. (2017) · Nature Communications · doi:10.1038/s41467-017-00492-w · Cited by 330
Nuclear pores dilate and constrict in cellulo
Zimmerli, C. E., Allegretti, M., Rantos, V., Goetz, S. K., Obarska-Kosinska, A., Zagoriy, I., Halavatyi, A., Hummer, G., Mahamid, J., Kosinski, J., et al. (2021) · Science · doi:10.1126/science.abd9776 · Cited by 324
Structure of the adenosine-bound human adenosine A1 receptor–Gi complex
Draper-Joyce, C. J., Khoshouei, M., Thal, D. M., Liang, Y.-L., Nguyen, A. T. N., Furness, S. G. B., Venugopal, H., Baltos, J.-A., Plitzko, J. M., Danev, R., et al. (2018) · Nature · doi:10.1038/s41586-018-0236-6 · Cited by 317
Self-citationCryo-Electron Tomography: Can it Reveal the Molecular Sociology of Cells in Atomic Detail?
Beck, M., & Baumeister, W. (2016) · Trends in Cell Biology · doi:10.1016/j.tcb.2016.08.006 · Cited by 316
Self-citationPhase-plate cryo-EM structure of a biased agonist-bound human GLP-1 receptor–Gs complex
Liang, Y.-L., Khoshouei, M., Glukhova, A., Furness, S. G. B., Zhao, P., Clydesdale, L., Koole, C., Truong, T. T., Thal, D. M., Lei, S., et al. (2018) · Nature · doi:10.1038/nature25773 · Cited by 315
Self-citationA molecular census of 26 S proteasomes in intact neurons
Asano, S., Fukuda, Y., Beck, F., Aufderheide, A., Förster, F., Danev, R., & Baumeister, W. (2015) · Science · doi:10.1126/science.1261197 · Cited by 311
Self-citationAn introduction to sample preparation and imaging by cryo-electron microscopy for structural biology
Thompson, R. F., Walker, M., Siebert, C. A., Muench, S. P., & Ranson, N. A. (2016) · Methods · doi:10.1016/j.ymeth.2016.02.017 · Cited by 282
Cryo-Electron Tomography and Subtomogram Averaging
Wan, W., & Briggs, J. A. G. (2016) · Methods in Enzymology · doi:10.1016/bs.mie.2016.04.014 · Cited by 278
Schaffer, M., Mahamid, J., Engel, B. D., Laugks, T., Baumeister, W., & Plitzko, J. M. (2017) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.07.010 · Cited by 260
Self-citationCryo-EM structure of the adenosine A2A receptor coupled to an engineered heterotrimeric G protein
García-Nafría, J., Lee, Y., Bai, X., Carpenter, B., & Tate, C. G. (2018) · eLife · doi:10.7554/elife.35946 · Cited by 253
Cryo-EM structure of haemoglobin at 3.2 Å determined with the Volta phase plate
Khoshouei, M., Radjainia, M., Baumeister, W., & Danev, R. (2017) · Nature Communications · doi:10.1038/ncomms16099 · Cited by 234
Self-citationCryo-Electron Microscopy Methodology: Current Aspects and Future Directions
Danev, R., Yanagisawa, H., & Kikkawa, M. (2019) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2019.04.008 · Cited by 229
Self-citationTao, C.-L., Liu, Y.-T., Sun, R., Zhang, B., Qi, L., Shivakoti, S., Tian, C.-L., Zhang, P., Lau, P.-M., Zhou, Z. H., et al. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.1548-17.2017 · Cited by 207
“By implementing the latest cryo-ET technologies, including VPP, electron energy filter, and direct electron detection, which greatly improve resolution and signal-to-noise ratio (Danev et al., 2014; Fukuda et al., 2015), we were able to visualize synaptic ultrastructural features.”
BackgroundMethodFranken, L. E., Boekema, E. J., & Stuart, M. C. A. (2017) · Advanced Science · doi:10.1002/advs.201600476 · Cited by 207
“(2015) C C Dong et al. (2015) S NI Hollow versus massive cannot be concluded from staining Wang et al.”
BackgroundSingle particle electron cryomicroscopy: trends, issues and future perspective
Vinothkumar, K. R., & Henderson, R. (2016) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583516000068 · Cited by 206
“These include the development of phase plates (Danev et al. 2014; Glaeser, 2013; Murata et al. 2010; Nagayama, 2014), Cc correctors (Kabius et al. 2009) and cooling to liquid helium temperature (Fujiyoshi, 1998) provided that the problems of beam-induced movement can be minimised.”
BackgroundResolution and aberration correction in liquid cell transmission electron microscopy
de Jonge, N., Houben, L., Dunin-Borkowski, R. E., & Ross, F. M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0071-2 · Cited by 206
Laser phase plate for transmission electron microscopy
Schwartz, O., Axelrod, J. J., Campbell, S. L., Turnbaugh, C., Glaeser, R. M., & Müller, H. (2019) · Nature Methods · doi:10.1038/s41592-019-0552-2 · Cited by 206
In Situ Cryo-Electron Tomography: A Post-Reductionist Approach to Structural Biology
Asano, S., Engel, B. D., & Baumeister, W. (2016) · Journal of Molecular Biology · doi:10.1016/j.jmb.2015.09.030 · Cited by 198
Self-citationSingle particle cryo-EM reconstruction of 52 kDa streptavidin at 3.2 Angstrom resolution
Fan, X., Wang, J., Zhang, X., Yang, Z., Zhang, J.-C., Zhao, L., Peng, H.-L., Lei, J., & Wang, H.-W. (2019) · Nature Communications · doi:10.1038/s41467-019-10368-w · Cited by 163
Cellular Electron Cryotomography: Toward Structural Biology In Situ
Oikonomou, C. M., & Jensen, G. J. (2017) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-061516-044741 · Cited by 162
Mahamid, J., Schampers, R., Persoon, H., Hyman, A. A., Baumeister, W., & Plitzko, J. M. (2015) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.07.012 · Cited by 161
Self-citationCryo-EM single particle analysis with the Volta phase plate
Danev, R., & Baumeister, W. (2016) · eLife · doi:10.7554/elife.13046 · Cited by 159
“DOI: 10.7554/eLife.13046 3 of 14 The phase shift of the VPP is not constant and increases with the accumulated dose on the phase plate (see Figure 3 below) (Danev et al., 2014, Figure 1).”
BackgroundResultInfluentialSelf-citationIn situ architecture of the lipid transport protein VPS13C at ER–lysosome membrane contacts
Cai, S., Wu, Y., Guillén-Samander, A., Hancock-Cerutti, W., Liu, J., & De Camilli, P. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2203769119 · Cited by 93
Dymek, E. E., Lin, J., Fu, G., Porter, M. E., Nicastro, D., & Smith, E. F. (2019) · Molecular Biology of the Cell · doi:10.1091/mbc.e19-01-0063 · Cited by 61
“Axonemes that appeared well preserved (e.g., not compressed) by EM inspection were imaged using both a VoltaPhase-Plate at −0.5 μm defocus, making contrast transfer function correction unnecessary (Danev et al., 2014), and an energy filter in zero-loss mode (20-eV slit width; Gatan, Pleasanton, CA).”
MethodInfluentialDeterminants shaping the nanoscale architecture of the mouse rod outer segment
Pöge, M., Mahamid, J., Imanishi, S. S., Plitzko, J. M., Palczewski, K., & Baumeister, W. (2021) · eLife · doi:10.7554/elife.72817 · Cited by 50
Self-citationStructural organization of the C1a-e-c supercomplex within the ciliary central apparatus
Fu, G., Zhao, L., Dymek, E., Hou, Y., Song, K., Phan, N., Shang, Z., Smith, E. F., Witman, G. B., & Nicastro, D. (2019) · Journal of Cell Biology · doi:10.1083/jcb.201906006 · Cited by 48
Structural organization of the C1a-e-c supercomplex within the ciliary central apparatus
Fu, G., Zhao, L., Dymek, E., Hou, Y., Song, K., Phan, N., Shang, Z., Smith, E. F., Witman, G. B., & Nicastro, D. (2019) · doi:10.1101/773416 · Cited by 48
Metadata
- Authors
- Danev, R., Buijsse, B., Khoshouei, M., Plitzko, J. M., & Baumeister, W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2014-10-20
- Volume
- 111
- Issue
- 44
- Pages
- 15635-15640
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2087960949
- Cited by
- 487
- References
- 13
- FWCI
- 25.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.