Enzymatically enhanced collisions on ultramicroelectrodes for specific and rapid detection of individual viruses
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Significance: Specific detection of individual nanometer-scale entities has been largely unavailable in the field of electrochemical collisions, where a change in amperometric current due to nonspecific adsorption at an ultramicroelectrode surface signals a collision. We have extended the field of collisions by achieving specific detection of individual virions with an antibody–epitope interaction and enzymatic amplification. This degree of selectivity and sensitivity (limit of detection ∼30 fM, signal-to-noise ratio ∼10–20) allows for a type of digital ELISA, where a discrete increase in current corresponds to the collision of a single virion on an ultramicroelectrode. We advanced the methodology to show that individual viruses can be observed in the urine of infected mice to demonstrate the technique’s potential efficacy as a digital electrochemical immunosensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Upton, J. W., Kaiser, W. J., & Mocarski, E. S. (2012) · Cell Host & Microbe · doi:10.1016/j.chom.2012.01.016 · Cited by 758 · cited 1×
“The shape of the curve correlates well with previously reported concentrations of infectious virus seen in the liver, spleen, and salivary glands from organ titers (23).”
BackgroundSelf-citationTime-Resolved Electrochemical Detection of Discrete Adsorption Events
Quinn, B. M., van't Hof, P. G., & Lemay, S. G. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0478577 · Cited by 274
Observation of Single-Protein and DNA Macromolecule Collisions on Ultramicroelectrodes
Dick, J. E., Renault, C., & Bard, A. J. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b04545 · Cited by 215 · cited 1×
“T development of methods to observe collisions on ultramicroelectrodes (UMEs) has allowed for the study of single entities, such as single nanoparticles (1), emulsion droplets (2, 3), vesicles (4, 5), biological macromolecules (6), and even single ions (7), in a digital manner (8).”
BackgroundSelf-citationCorrelated Electrochemical and Optical Tracking of Discrete Collision Events
Fosdick, S. E., Anderson, M. J., Nettleton, E. G., & Crooks, R. M. (2013) · Journal of the American Chemical Society · doi:10.1021/ja401864k · Cited by 166
Dick, J. E., Hilterbrand, A. T., Boika, A., Upton, J. W., & Bard, A. J. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1504294112 · Cited by 166 · cited 5×
“aCenter for Electrochemistry, Department of Chemistry, The University of Texas at Austin, Austin, TX 78712; and bDepartment of Molecular Biosciences, LaMontagne Center for Infectious Disease, and Institute for Cellular and Molecular Biology, The University of Texas at Austin, Austin, TX 78712 Contributed by Allen J. B…”
BackgroundInfluentialSelf-citationBoika, A., Thorgaard, S. N., & Bard, A. J. (2013) · The Journal of Physical Chemistry B · doi:10.1021/jp306934g · Cited by 160
Self-citationElectrochemical Detection of Single Phospholipid Vesicle Collisions at a Pt Ultramicroelectrode
Lebègue, E., Anderson, C. M., Dick, J. E., Webb, L. J., & Bard, A. J. (2015) · Langmuir · doi:10.1021/acs.langmuir.5b03123 · Cited by 137 · cited 1×
“T development of methods to observe collisions on ultramicroelectrodes (UMEs) has allowed for the study of single entities, such as single nanoparticles (1), emulsion droplets (2, 3), vesicles (4, 5), biological macromolecules (6), and even single ions (7), in a digital manner (8).”
Self-citation
Cited by
Observation of Multipeak Collision Behavior during the Electro-Oxidation of Single Ag Nanoparticles
Oja, S. M., Robinson, D. A., Vitti, N. J., Edwards, M. A., Liu, Y., White, H. S., & Zhang, B. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b11143 · Cited by 210
Review—Electrochemistry's Potential to Reach the Ultimate Sensitivity in Measurement Science
Goines, S., & Dick, J. E. (2020) · Journal of The Electrochemical Society · doi:10.1149/2.0052003jes · Cited by 81
Self-citationToward the Detection and Identification of Single Bacteria by Electrochemical Collision Technique
Gao, G., Wang, D., Brocenschi, R., Zhi, J., & Mirkin, M. V. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03043 · Cited by 75
Ronspees, A. T., & Thorgaard, S. N. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.05.006 · Cited by 46
Millisecond Coulometry via Zeptoliter Droplet Collisions on an Ultramicroelectrode
Dick, J. E., Lebègue, E., Strawsine, L. M., & Bard, A. J. (2016) · Electroanalysis · doi:10.1002/elan.201600182 · Cited by 46
Self-citation
Metadata
- Authors
- Dick, J. E., Hilterbrand, A. T., Strawsine, L. M., Upton, J. W., & Bard, A. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2016-05-23
- Volume
- 113
- Issue
- 23
- Pages
- 6403-6408
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2394932444
- Cited by
- 105
- References
- 8
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enzymatically enhanced collisions on ultramicroelectrodes for specific and rapid detection of individual viruses. https://app.cochat.ai/papers/10.1073/pnas.1605002113
- The paper
- Dick, J. E., Hilterbrand, A. T., Strawsine, L. M., Upton, J. W., & Bard, A. J. (2016). Enzymatically enhanced collisions on ultramicroelectrodes for specific and rapid detection of individual viruses. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1605002113
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.