Molecular imaging with endogenous substances
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Dynamic nuclear polarization has enabled hyperpolarization of nuclei such as 13 C and 15 N in endogenous substances. The resulting high nuclear polarization makes it possible to perform subsecond 13 C MRI. By using the dynamic nuclear polarization hyperpolarization technique, 10% polarization was obtained in an aqueous solution of 100 mM 13 C-labeled urea, ready for injection. The in vivo T 1 relaxation time of 13 C in the urea solution was determined to 20 ± 2 s. Due to the long relaxation time, it is possible to use the hyperpolarized substance for medical imaging. A series of high-resolution (≈1-mm) magnetic resonance images were acquired, each with a scan time of 240 ms, 0-5 s after an i.v. injection of the hyperpolarized aqueous [ 13 C]urea solution in a rat. The results show that it is possible to perform 13 C angiography with a signal-to-noise ratio of ≈275 in ≈0.25 s. Perfusion studies with endogenous substances may allow higher spatial and/or temporal resolution than is possible with current proton imaging techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Increase in signal-to-noise ratio of > 10,000 times in liquid-state NMR
Ardenkjær-Larsen, J. H., Fridlund, B., Gram, A., Hansson, G., Hansson, L., Lerche, M. H., Servin, R., Thaning, M., & Golman, K. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1733835100 · Cited by 2,861
Self-citationMagnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Polarization of Nuclei in Metals
Overhauser, A. W. (1953) · Physical Review · doi:10.1103/physrev.92.411 · Cited by 1,710
The intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
Multispectral analysis of the temporal evolution of cerebral ischemia in the rat brain
Carano, R. A. D., Li, F., Irie, K., Helmer, K. G., Silva, M. D., Fisher, M., & Sotak, C. H. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200012)12:6<929::aid-jmri17>3.0.co;2-j · Cited by 88
Gilfeather, M., Holland, G. A., Siegelman, E. S., Schnall, M. D., Axel, L., Carpenter, J. P., & Golden, M. A. (1997) · RadioGraphics · doi:10.1148/radiographics.17.2.9084082 · Cited by 51
Measurement of myocardial blood flow with PET using 1-11C-acetate.
Sciacca, R. R., Akinboboye, O. O., Chou, R. L., Epstein, S., & Bergmann, S. R. (2001) · PubMed · Cited by 42
Transport into retina measured by short vascular perfusion in the rat.
Gratton, J. A., Lightman, S., & Bradbury, M. W. B. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019880 · Cited by 17
Cited by
Increase in signal-to-noise ratio of > 10,000 times in liquid-state NMR
Ardenkjær-Larsen, J. H., Fridlund, B., Gram, A., Hansson, G., Hansson, L., Lerche, M. H., Servin, R., Thaning, M., & Golman, K. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1733835100 · Cited by 2,861
Self-citationChemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Reversible Interactions with para-Hydrogen Enhance NMR Sensitivity by Polarization Transfer
Adams, R. W., Aguilar, J. A., Atkinson, K. D., Cowley, M. J., Elliott, P. I. P., Duckett, S. B., Green, G. G. R., Khazal, I. G., López-Serrano, J., & Williamson, D. C. (2009) · Science · doi:10.1126/science.1168877 · Cited by 1,031
Day, S. E., Kettunen, M. I., Gallagher, F. A., Hu, D.-E., Lerche, M., Wolber, J., Golman, K., Ardenkjaer-Larsen, J. H., & Brindle, K. M. (2007) · Nature Medicine · doi:10.1038/nm1650 · Cited by 883
Self-citationKurhanewicz, J., Vigneron, D. B., Brindle, K., Chekmenev, E. Y., Comment, A., Cunningham, C. H., DeBerardinis, R. J., Green, G. G., Leach, M. O., Rajan, S. S., et al. (2011) · Neoplasia · doi:10.1593/neo.101102 · Cited by 681
“[108] Golman K, Ardenaer-Larsen JH, Petersson JS, Mansson S, and Leunbach I (2003).”
BackgroundGolman, K., in ‘t Zandt, R., & Thaning, M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0601319103 · Cited by 659
Self-citationTatum, J. L. (2006) · International Journal of Radiation Biology · doi:10.1080/09553000601002324 · Cited by 620
Metabolic Imaging by Hyperpolarized 13C Magnetic Resonance Imaging for In vivo Tumor Diagnosis
Golman, K., Zandt, R. I., Lerche, M., Pehrson, R., & Ardenkjaer-Larsen, J. H. (2006) · Cancer Research · doi:10.1158/0008-5472.can-06-2564 · Cited by 591
Self-citationClassification and basic properties of contrast agents for magnetic resonance imaging
Geraldes, C. F. G. C., & Laurent, S. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.265 · Cited by 541
New approaches for imaging tumour responses to treatment
Brindle, K. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2289 · Cited by 460
Hyperpolarized 13C MRI: Path to Clinical Translation in Oncology
Kurhanewicz, J., Vigneron, D. B., Ardenkjaer-Larsen, J. H., Bankson, J. A., Brindle, K., Cunningham, C. H., Gallagher, F. A., Keshari, K. R., Kjaer, A., Laustsen, C., et al. (2019) · Neoplasia · doi:10.1016/j.neo.2018.09.006 · Cited by 440
Employing Metabolism to Improve the Diagnosis and Treatment of Pancreatic Cancer
Halbrook, C. J., & Lyssiotis, C. A. (2017) · Cancer Cell · doi:10.1016/j.ccell.2016.12.006 · Cited by 393
Spin Hyperpolarization in Modern Magnetic Resonance
Eills, J., Budker, D., Cavagnero, S., Chekmenev, E. Y., Elliott, S. J., Jannin, S., Lesage, A., Matysik, J., Meersmann, T., Prisner, T., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00534 · Cited by 368
Keshari, K. R., & Wilson, D. M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60124b · Cited by 358
Hyperpolarized 13 C allows a direct measure of flux through a single enzyme-catalyzed step by NMR
Merritt, M. E., Harrison, C., Storey, C., Jeffrey, F. M., Sherry, A. D., & Malloy, C. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706235104 · Cited by 278
Miloushev, V. Z., Granlund, K. L., Boltyanskiy, R., Lyashchenko, S. K., DeAngelis, L. M., Mellinghoff, I. K., Brennan, C. W., Tabar, V., Yang, T. J., Holodny, A. I., et al. (2018) · Cancer Research · doi:10.1158/0008-5472.can-18-0221 · Cited by 216
“Endogenously occurring molecules are hyperpolarized ex vivo and injected intravenously, allowing the hyperpolarized label to be followed as the molecule is distributed and metabolized in the human body (9, 10).”
BackgroundLarson, P. E. Z., Hu, S., Lustig, M., Kerr, A. B., Nelson, S. J., Kurhanewicz, J., Pauly, J. M., & Vigneron, D. B. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22650 · Cited by 192
“The high signal enhancement of hyperpolarized agents in vivo has been made possible by the development of methods utilizing dynamic nuclear polarization (DNP) and rapid dissolution techniques that provide a Signal-to-Noise Ratio (SNR) increase of over 40,000 for [1-13C]-pyruvate while producing an injectable solution…”
Workman, P., Aboagye, E. O., Chung, Y.-L., Griffiths, J. R., Hart, R., Leach, M. O., Maxwell, R. J., McSheehy, P. M. J., Price, P. M., & Zweit, J. (2006) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djj162 · Cited by 188
13C imaging—a new diagnostic platform
Månsson, S., Johansson, E., Magnusson, P., Chai, C.-M., Hansson, G., Petersson, J. S., Ståhlberg, F., & Golman, K. (2006) · European Radiology · doi:10.1007/s00330-005-2806-x · Cited by 181
“Hyperpolarized (13)C has only recently become available at polarization levels adequate for MRI [11, 12, 19, 25, 26].”
Self-citationWilson, D. M., Keshari, K. R., Larson, P. E. Z., Chen, A. P., Hu, S., Criekinge, M. V., Bok, R., Nelson, S. J., Macdonald, J. M., Vigneron, D. B., et al. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.04.012 · Cited by 174
“In vivo hyperpolarized MR is unprecedented in its ability to characterize specific enzymatic pathways(2,3).”
Background
Metadata
- Authors
- Golman, K., Ardenkjær-Larsen, J. H., Petersson, J. S., Månsson, S., & Leunbach, I.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2003-08-20
- Volume
- 100
- Issue
- 18
- Pages
- 10435-10439
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2002190301
- Cited by
- 427
- References
- 8
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.