Soft, skin-interfaced microfluidic systems with integrated immunoassays, fluorometric sensors, and impedance measurement capabilities
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Significance: Skin-interfaced, wireless devices for clinical-grade monitoring of physiological parameters are of growing interest for uses that range from healthcare to sports performance. This paper introduces a multifunctional skin-mounted microfluidic platform for capture and biomarker analysis of microliter volumes of sweat, a biofluid that can be collected noninvasively, with potential relevance in biophysical sensing. The focus is on colorimetric and digital assessments of a collection of parameters related to stress, including concentrations of vitamin C, cortisol, and glucose, along with quantitative measurements of sweat rate and galvanic skin response. The results represent important additions to a portfolio of emerging capabilities in skin-interfaced technologies for physiological monitoring, with particular relevance to conditions that follow from unhealthy levels of physical and mental stress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Sweat can be collected by capillary wicking into microfluidic pores fabricated into a synthetic polymer membrane that is directly in contact with the skin surface90–93.”
From End-to-end design of wearable sensors (2022) · cites this paper as [90]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationSwinehart, D. F. (1962) · Journal of Chemical Education · doi:10.1021/ed039p333 · Cited by 1,969
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Self-citationA soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Self-citationBiology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717
A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Investigation of Cortisol Dynamics in Human Sweat Using a Graphene-Based Wireless mHealth System
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.021 · Cited by 479
Liu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397
Self-citation
Research works printed but not linked: 47
- 10.1002/smll.201703334 · DOI · Paper page
- 10.1002/jlb.57.3.434 · DOI · Paper page
- 10.1016/j.jpba.2013.10.048 · DOI · Paper page
- 10.1016/j.jim.2017.11.003 · DOI
- 10.2114/jpa.17.219 · DOI
- 10.1002/adma.201902109 · DOI · Paper page
- 10.1038/s41467-019-13431-8 · DOI
- 10.1002/smll.201802876 · DOI
- 10.1111/nure.12157 · DOI
- 10.1080/07315724.2007.10719656 · DOI · Paper page
- 10.7205/MILMED-D-03-2508 · DOI
- 10.1016/0306-4530(92)90078-L · DOI
- 10.1016/j.ygcen.2006.02.013 · DOI · Paper page
- J. Gordon Betts ., “The adrenal glands” in Anatomy and Physiology (BCcampus, Victoria, BC, Canada, 2020), Chap. 17.6.
- 10.1016/j.compscitech.2019.02.001 · DOI
- 10.1039/C9LC01045A · DOI
- 10.1016/j.jim.2003.07.009 · DOI
- 10.1016/j.sbsr.2014.08.001 · DOI · Paper page
- 10.1039/C4AY02940B · DOI
- 10.1016/j.jcis.2017.07.011 · DOI
- 10.1039/C9BM00129H · doi:10.1039/c9bm00129h
- 10.1016/j.chroma.2016.11.040 · doi:10.1016/j.chroma.2016.11.040
- 10.1039/c2jm33482h · DOI
- 10.1007/s10544-005-1596-x · doi:10.1007/s10544-005-1596-x
- 10.1016/j.ijfoodmicro.2004.07.021 · doi:10.1016/j.ijfoodmicro.2004.07.021
- 10.1007/s00396-005-1428-9 · DOI
- 10.1146/annurev-anchem-061417-125737 · DOI
- 10.1103/PhysRev.17.273 · DOI · Paper page
- 10.1002/adfm.201604465 · DOI · Paper page
- 10.1159/000184628 · DOI · Paper page
- 10.1002/adhm.201601355 · DOI · Paper page
- S. Jayaraman, Flow cytometric determination of mitochondrial membrane potential changes during apoptosis of T lymphocytic and pancreatic beta cell lines: Comparison of tetramethylrhodamineethylester (TMRE), chloromethyl-X-rosamine (H2-CMX-Ros) and MitoTracker Red 580 (MTR580). J. Immunol. Methods 306, 68–79 (2005). · DOI
- 10.1016/j.bios.2014.02.059 · doi:10.1016/j.bios.2014.02.059
- 10.1038/nmeth.2089 · DOI · Paper page
- 10.1038/s41746-017-0009-x · DOI · Paper page
- 10.1007/s10286-003-0107-5 · DOI · Paper page
- 10.1016/j.jtherbio.2013.09.003 · DOI
- 10.1152/japplphysiol.00646.2010 · DOI
- 10.1007/s00421-015-3275-9 · DOI
- 10.1093/chromsci/46.1.1 · DOI
- 10.1016/j.jpsychores.2007.03.016 · DOI
- 10.1111/1365-2435.12039 · DOI · Paper page
- 10.1159/000258725 · DOI · Paper page
- 10.1371/journal.pone.0139662 · DOI
- 10.2170/jjphysiol.16.274 · DOI
- 10.1113/jphysiol.1989.sp017810 · DOI
- 10.1152/jappl.1984.57.6.1688 · DOI · Paper page
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring
Wang, B., Zhao, C., Wang, Z., Yang, K.-A., Cheng, X., Liu, W., Yu, W., Lin, S., Zhao, Y., Cheung, K. M., et al. (2022) · Science Advances · doi:10.1126/sciadv.abk0967 · Cited by 403
An autonomous wearable biosensor powered by a perovskite solar cell
Min, J., Demchyshyn, S., Sempionatto, J. R., Song, Y., Hailegnaw, B., Xu, C., Yang, Y., Solomon, S., Putz, C., Lehner, L. E., et al. (2023) · Nature Electronics · doi:10.1038/s41928-023-00996-y · Cited by 372
Wearable plasmonic paper–based microfluidics for continuous sweat analysis
Mogera, U., Guo, H., Namkoong, M., Rahman, M. S., Nguyen, T., & Tian, L. (2022) · Science Advances · doi:10.1126/sciadv.abn1736 · Cited by 280
Metadata
- Authors
- Kim, S., Lee, B., Reeder, J. T., Seo, S. H., Lee, S.-U., Hourlier-Fargette, A., Shin, J., Sekine, Y., Jeong, H., Oh, Y. S., Aranyosi, A. J., Lee, S. P., Model, J. B., Lee, G., Seo, M.-H., Kwak, S. S., Jo, S., Park, G., Han, S., Park, I., Jung, H.-I., Ghaffari, R., Koo, J., Braun, P. V., & Rogers, J. A.
- Affiliations
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208;
- Department of Medicine, Konkuk University, Seoul 05029, Republic of Korea;
- Nano Hybrid Technology Research Center, Electrical Materials Research Division, Korea Electrotechnology Research Institute, Changwon 51543, Republic of Korea;
- Accident Tolerant Fuels Technology Development Division, Korea Atomic Energy Research Institute, Daejeon 34057, Republic of Korea;
- Center for Electronic Materials, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea;
- Materials Sciences Research Center, Japan Atomic Energy Agency, Tokai, Ibaraki 319-1195, Japan;
- Materials Research Laboratory, University of Illinois at Urbana–Champaign, Urbana, IL 61801;
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea;
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea;
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea;
- Department of Materials Science and Engineering, University of Illinois at Urbana–Champaign, Urbana, IL 61801;
- ORCID
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2020-10-26
- Volume
- 117
- Issue
- 45
- Pages
- 27906-27915
- ISSN
- 0027-8424
- 1091-6490
- Cited by
- 151
- References
- 29
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Soft, skin-interfaced microfluidic systems with integrated immunoassays, fluorometric sensors, and impedance measurement capabilities. https://app.cochat.ai/papers/10.1073/pnas.2012700117
- The paper
- Kim, S., Lee, B., Reeder, J. T., Seo, S. H., Lee, S.-U., Hourlier-Fargette, A., Shin, J., Sekine, Y., Jeong, H., Oh, Y. S., Aranyosi, A. J., Lee, S. P., Model, J. B., Lee, G., Seo, M.-H., Kwak, S. S., Jo, S., Park, G., Han, S., . . . Rogers, J. A. (2020). Soft, skin-interfaced microfluidic systems with integrated immunoassays, fluorometric sensors, and impedance measurement capabilities. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.2012700117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.