Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 315

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Thin, Soft, Skin‐Mounted Microfluidic Networks with Capillary Bursting Valves for Chrono‐Sampling of Sweat

Choi, Jungil, Kang, Daeshik, Han, Seungyong, Kim, Sung Bong, Rogers, John A.·2017·Advanced Healthcare Materials

Abstract

Systems for time sequential capture of microliter volumes of sweat released from targeted regions of the skin offer the potential to enable analysis of temporal variations in electrolyte balance and biomarker concentration throughout a period of interest. Current methods that rely on absorbent pads taped to the skin do not offer the ease of use in sweat capture needed for quantitative tracking; emerging classes of electronic wearable sweat analysis systems do not directly manage sweat‐induced fluid flows for sample isolation. Here, a thin, soft, “skin‐like” microfluidic platform is introduced that bonds to the skin to allow for collection and storage of sweat in an interconnected set of microreservoirs. Pressure induced by the sweat glands drives flow through a network of microchannels that incorporates capillary bursting valves designed to open at different pressures, for the purpose of passively guiding sweat through the system in sequential fashion. A representative device recovers 1.8 µL volumes of sweat each from 0.8 min of sweating into a set of separate microreservoirs, collected from 0.03 cm 2 area of skin with approximately five glands, corresponding to a sweat rate of 0.60 µL min−1 per gland. Human studies demonstrate applications in the accurate chemical analysis of lactate, sodium, and potassium concentrations and their temporal variations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adhm.201601355

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 315

Metadata

Authors
Choi, J., Kang, D., Han, S., Kim, S. B., & Rogers, J. A.
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2017-01-20
Volume
6
Issue
5
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W2579323355
Cited by
315
References
16
FWCI
11.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thin, Soft, Skin‐Mounted Microfluidic Networks with Capillary Bursting Valves for Chrono‐Sampling of Sweat. https://app.cochat.ai/papers/10.1002/adhm.201601355
The paper
Choi, J., Kang, D., Han, S., Kim, S. B., & Rogers, J. A. (2017). Thin, Soft, Skin‐Mounted Microfluidic Networks with Capillary Bursting Valves for Chrono‐Sampling of Sweat. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201601355

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.