Electronic detection of DNA by its intrinsic molecular charge
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
We report the selective and real-time detection of label-free DNA using an electronic readout. Microfabricated silicon field-effect sensors were used to directly monitor the increase in surface charge when DNA hybridizes on the sensor surface. The electrostatic immobilization of probe DNA on a positively charged poly- l -lysine layer allows hybridization at low ionic strength where field-effect sensing is most sensitive. Nanomolar DNA concentrations can be detected within minutes, and a single base mismatch within 12-mer oligonucleotides can be distinguished by using a differential detection technique with two sensors in parallel. The sensors were fabricated by standard silicon microtechnology and show promise for future electronic DNA arrays and rapid characterization of nucleic acid samples. This approach demonstrates the most direct and simple translation of genetic information to microelectronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
Fuzzy Nanoassemblies: Toward Layered Polymeric Multicomposites
Decher, G. (1997) · Science · doi:10.1126/science.277.5330.1232 · Cited by 10,054
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Scanometric DNA Array Detection with Nanoparticle Probes
Taton, T. A., Mirkin, C. A., & Letsinger, R. L. (2000) · Science · doi:10.1126/science.289.5485.1757 · Cited by 2,411
MOS /metal oxide semiconductor/ physics and technology
Nicollian, E. H., & Brews, J. R. (1982) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,098
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Self-citationKinetics of renaturation of DNA
Wetmur, J. G., & Davidson, N. (1968) · Journal of Molecular Biology · doi:10.1016/0022-2836(68)90414-2 · Cited by 1,422
Sequence-specific detection of individual DNA strands using engineered nanopores
Howorka, S., Cheley, S., & Bayley, H. (2001) · Nature Biotechnology · doi:10.1038/90236 · Cited by 760
SURVEY AND SUMMARY: From DNA biosensors to gene chips
Wang, J. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.16.3011 · Cited by 753
Light-Addressable Potentiometric Sensor for Biochemical Systems
Hafeman, D. G., Parce, J. W., & McConnell, H. M. (1988) · Science · doi:10.1126/science.3375810 · Cited by 709
Cited by
An integrated semiconductor device enabling non-optical genome sequencing
Rothberg, J. M., Hinz, W., Rearick, T. M., Schultz, J., Mileski, W., Davey, M., Leamon, J. H., Johnson, K., Milgrew, M. J., Edwards, M., et al. (2011) · Nature · doi:10.1038/nature10242 · Cited by 2,172
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Cell and molecular mechanics of biological materials
Bao, G., & Suresh, S. (2003) · Nature Materials · doi:10.1038/nmat1001 · Cited by 1,055
Fan, C., Plaxco, K. W., & Heeger, A. J. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1633515100 · Cited by 1,043
Electronic Aptamer‐Based Sensors
Willner, I., & Zayats, M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604524 · Cited by 818
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Label-free detection of DNA hybridization using carbon nanotube network field-effect transistors
Star, A., Tu, E., Niemann, J., Gabriel, J.-C. P., Joiner, C. S., & Valcke, C. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504146103 · Cited by 670
One dimensional nanostructured materials
Kuchibhatla, S. V. N. T., Karakoti, A. S., Bera, D., & Seal, S. (2007) · Progress in Materials Science · doi:10.1016/j.pmatsci.2006.08.001 · Cited by 631
Bunimovich, Y. L., Shin, Y. S., Yeo, W.-S., Amori, M., Kwong, G., & Heath, J. R. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065923u · Cited by 480
BioMEMS: state-of-the-art in detection, opportunities and prospects
Bashir, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.03.002 · Cited by 462
Ion-Sensitive Field-Effect Transistor for Biological Sensing
Lee, C.-S., Kim, S. K., & Kim, M. (2009) · Sensors · doi:10.3390/s90907111 · Cited by 426
Carbon nanotube transistors for biosensing applications
Gruner, G. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3400-4 · Cited by 408
DNA Base Detection Using a Single-Layer MoS2
Farimani, A. B., Min, K., & Aluru, N. R. (2014) · ACS Nano · doi:10.1021/nn5029295 · Cited by 355
Performance limits of nanobiosensors
Nair, P. R., & Alam, M. A. (2006) · Applied Physics Letters · doi:10.1063/1.2211310 · Cited by 341
Recent trends in electrochemical DNA biosensor technology
Kerman, K., Kobayashi, M., & Tamiya, E. (2004) · Measurement Science and Technology · doi:10.1088/0957-0233/15/2/r01 · Cited by 330
Proposal for tunnel-field-effect-transistor as ultra-sensitive and label-free biosensors
Sarkar, D., & Banerjee, K. (2012) · Applied Physics Letters · doi:10.1063/1.3698093 · Cited by 295
Poghossian, A., Cherstvy, A., Ingebrandt, S., Offenhäusser, A., & Schöning, M. J. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.03.083 · Cited by 261
Labelfree fully electronic nucleic acid detection system based on a field-effect transistor device
Uslu, F., Ingebrandt, S., Mayer, D., Böcker-Meffert, S., Odenthal, M., & Offenhäusser, A. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.01.019 · Cited by 255
Suspended microchannel resonators for biomolecular detection
Burg, T. P., & Manalis, S. R. (2003) · Applied Physics Letters · doi:10.1063/1.1611625 · Cited by 237
Self-citationDevelopment of electrochemical DNA biosensors
Liu, A., Wang, K., Weng, S., Lei, Y., Lin, L., Chen, W., Lin, X., & Chen, Y. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.03.008 · Cited by 190
Label-Free DNA Biosensors Based on Functionalized Carbon Nanotube Field Effect Transistors
Martínez, M. T., Tseng, Y.-C., Ormategui, N., Loinaz, I., Eritja, R., & Bokor, J. (2009) · Nano Letters · doi:10.1021/nl8025604 · Cited by 164
Landheer, D., Aers, G., McKinnon, W. R., Deen, M. J., & Ranuarez, J. C. (2005) · Journal of Applied Physics · doi:10.1063/1.2008354 · Cited by 163
Biological shot-noise and quantum-limited signal-to-noise ratio in affinity-based biosensors
Hassibi, A., Zahedi, S., Navid, R., Dutton, R. W., & Lee, T. H. (2005) · Journal of Applied Physics · doi:10.1063/1.1861970 · Cited by 73
Metadata
- Authors
- Fritz, J., Cooper, E. B., Gaudet, S., Sorger, P. K., & Manalis, S. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2002-10-17
- Volume
- 99
- Issue
- 22
- Pages
- 14142-14146
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2031495754
- Cited by
- 443
- References
- 24
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.