Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The kinetics of the fall in subcutaneous fluid glucose concentration in anesthetized rats ( n = 7) after intravenous injection of insulin (0.5 units/kg) was studied by using 5 × 10 −4 cm 2 active area, <150-sec 10–90% response time, amperometric glucose sensors. The onset of the decline in the subcutaneous glucose concentration was delayed and statistically different ( P < 0.001) from that in blood (8.9 ± 2.1 min vs. 3.3 ± 0.5 min). Similarly, the rate of drop in glucose concentration between 6 and 20 min after the insulin injection was different for subcutaneous tissue (3.9 ± 1.3 mg⋅dl −1 ⋅ min −1 ) and blood (6.8 ± 2.0 mg⋅dl −1 ⋅min −1 ) ( P = 0.003). The hypoglycemic nadir in subcutaneous fluid occurred 24.5 ± 6.8 min after that in the blood ( P < 0.001). A “forward” mass-transfer model, predicting the subcutaneous glucose concentration from the blood glucose concentrations and an “inverse” model, predicting the blood glucose concentration from the subcutaneous glucose concentration were derived. By using an algorithm based on the latter, the average discrepancy between the measured blood glucose concentration and that estimated from the subcutaneous measurement through the entire 4-hr experiment was reduced from 22.9% to 11.1% ( P = 0.025). The maximum discrepancy during the 40-min period after the injection of insulin was reduced from 84.1% to 29.3% ( P = 0.006).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1995) · Diabetes Care · doi:10.2337/diacare.18.11.1415 · Cited by 305
Self-Monitoring of Blood Glucose
American Diabetes Association (1994) · Diabetes Care · doi:10.2337/diacare.17.1.81 · Cited by 255
Cited by
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Self-citationGlucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
“Therefore, subcutaneously implantable needle-type electrodes measuring glucose concentrations in interstitial fluid have been developed, which reflect the blood glucose level [73-77].”
BackgroundGlucose Biosensors: 40 Years of Advances and Challenges
Wang, J. (2001) · Electroanalysis · doi:10.1002/1521-4109(200108)13:12<983::aid-elan983>3.0.co;2-# · Cited by 752
Biosensors in clinical chemistry
D'Orazio, P. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00241-9 · Cited by 524
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Rebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.277.3.e561 · Cited by 366
O2Reduction in Enzymatic Biofuel Cells
Mano, N., & de Poulpiquet, A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00220 · Cited by 337
Electrochemical Sensors, Biosensors and their Biomedical Applications
(2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373738-0.x5001-6 · Cited by 333
Closed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313
Glucose Biosensor Based on the Microcantilever
Pei, J., Tian, F., & Thundat, T. (2004) · Analytical Chemistry · doi:10.1021/ac035048k · Cited by 284
Noninvasive Glucose Monitoring: Comprehensive Clinical Results
Tamada, J. A., Garg, S., Jovanovic, L., Pitzer, K. R., Fermi, S., Potts, R. O., & and the Cygnus Research Team (1999) · JAMA · doi:10.1001/jama.282.19.1839 · Cited by 282
Barone, P. W., Parker, R. S., & Strano, M. S. (2005) · Analytical Chemistry · doi:10.1021/ac0511997 · Cited by 279
Electrochemistry in Diabetes Management
Heller, A., & Feldman, B. (2010) · Accounts of Chemical Research · doi:10.1021/ar9002015 · Cited by 255
Self-citationImplanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215
Self-citationContinuous Glucose Monitoring: Real-Time Algorithms for Calibration, Filtering, and Alarms
Bequette, B. W. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400222 · Cited by 192
Guinel, F. C., & Geil, R. D. (2002) · Canadian Journal of Botany · doi:10.1139/b02-066 · Cited by 174
Electroanalysis and Biosensors
Wang, J. (1999) · Analytical Chemistry · doi:10.1021/a1999905e · Cited by 159
Rebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152
Assessment of transcapillary glucose exchange in human skeletal muscle and adipose tissue
Regittnig, W., Ellmerer, M., Fauler, G., Sendlhofer, G., Trajanoski, Z., Leis, H.-J., Schaupp, L., Wach, P., & Pieber, T. R. (2003) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00351.2002 · Cited by 41
Metadata
- Authors
- Schmidtke, D. W., Freeland, A. C., Heller, A., & Bonnecaze, R. T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1998-01-06
- Volume
- 95
- Issue
- 1
- Pages
- 294-299
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1971694648
- Cited by
- 118
- References
- 2
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.