Mass Spectrometric Analysis of Protein Mixtures at Low Levels Using Cleavable 13C-Isotope-coded Affinity Tag and Multidimensional Chromatography
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
In order to identify and compare the protein content of very low quantity samples of high complexity, a protocol has been established that combines the differential profiling strength of a new cleavable 13C isotope-coded affinity tag (cICAT) reagent with the high sequence coverage provided by multidimensional liquid chromatography and two modes of tandem mass spectrometry. Major objectives during protocol optimization were to minimize sample losses and establish a robust procedure that employs volatile buffer systems that are highly compatible with mass spectrometry. Cleavable ICAT-labeled tryptic peptides were separated from nonlabeled peptides by avidin affinity chromatography. Subsequently, peptide samples were analyzed by nanoflow liquid chromatography electrospray ionization tandem mass spectrometry and liquid chromatography matrix-assisted laser desorption/ionization tandem mass spectrometry. The use of two ionization/instrumental configurations led to complementary peptide identifications that increased the confidence of protein assignments. Examples that illustrate the power of this strategy are taken from two different projects: i) immunoaffinity purified complexes containing the prion protein from the murine brain, and ii) human tracheal epithelium gland secretions. In these studies, a large number of novel proteins were identified using stringent match criteria, in addition to many that had been identified in previous experiments. In the latter case, the ICAT method produced significant new information on changes that occur in protein expression levels in a patient suffering from cystic fibrosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High resolution two-dimensional electrophoresis of proteins.
O'Farrell, P. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41496-8 · Cited by 19,246
Large-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752
Difference gel electrophoresis. A single gel method for detecting changes in protein extracts
Ünlü, M., Morgan, M. E., & Minden, J. S. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150181133 · Cited by 2,179
Klose, J. (1975) · Humangenetik · doi:10.1007/bf00281458 · Cited by 1,207
Han, D. K., Eng, J., Zhou, H., & Aebersold, R. (2001) · Nature Biotechnology · doi:10.1038/nbt1001-946 · Cited by 876
Proteolytic 18O Labeling for Comparative Proteomics: Model Studies with Two Serotypes of Adenovirus
Yao, X., Freas, A., Ramirez, J., Demirev, P. A., & Fenselau, C. (2001) · Analytical Chemistry · doi:10.1021/ac001404c · Cited by 759
Griffin, T. J., Gygi, S. P., Ideker, T., Rist, B., Eng, J., Hood, L., & Aebersold, R. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200001-mcp200 · Cited by 663
Binding of neural cell adhesion molecules (N-CAMs) to the cellular prion protein
Schmitt-Ulms, G., Legname, G., Baldwin, M. A., Ball, H. L., Bradon, N., Bosque, P. J., Crossin, K. L., Edelman, G. M., DeArmond, S. J., Cohen, F. E., et al. (2001) · Journal of Molecular Biology · doi:10.1006/jmbi.2000.5183 · Cited by 387
Self-citationQuantitative proteome analysis by solid-phase isotope tagging and mass spectrometry
Zhou, H., Ranish, J. A., Watts, J. D., & Aebersold, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0502-512 · Cited by 384
Barr, J. R., Maggio, V. L., Patterson, D. G., Cooper, G. R., Henderson, L. O., Turner, W. E., Smith, S. J., Hannon, W. H., Needham, L. L., & Sampson, E. J. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.10.1676 · Cited by 347
Cited by
Quantitative mass spectrometry in proteomics: a critical review
Bantscheff, M., Schirle, M., Sweetman, G., Rick, J., & Kuster, B. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1486-6 · Cited by 1,669
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Increasing the Multiplexing Capacity of TMTs Using Reporter Ion Isotopologues with Isobaric Masses
McAlister, G. C., Huttlin, E. L., Haas, W., Ting, L., Jedrychowski, M. P., Rogers, J. C., Kuhn, K., Pike, I., Grothe, R. A., Blethrow, J. D., et al. (2012) · Analytical Chemistry · doi:10.1021/ac301572t · Cited by 605
Wu, W. W., Wang, G., Baek, S. J., & Shen, R.-F. (2006) · Journal of Proteome Research · doi:10.1021/pr050405o · Cited by 576
Cheng, D., Hoogenraad, C. C., Rush, J., Ramm, E., Schlager, M. A., Duong, D. M., Xu, P., Wijayawardana, S. R., Hanfelt, J., Nakagawa, T., et al. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.d500009-mcp200 · Cited by 510
Protein abundance profiling of the Escherichia coli cytosol
Ishihama, Y., Schmidt, T., Rappsilber, J., Mann, M., Hartl, F. U., Kerner, M. J., & Frishman, D. (2008) · BMC Genomics · doi:10.1186/1471-2164-9-102 · Cited by 471
State‐of‐the‐art in phosphoproteomics
Reinders, J., & Sickmann, A. (2005) · PROTEOMICS · doi:10.1002/pmic.200401289 · Cited by 346
Quantification in Proteomics through Stable Isotope Coding: A Review
Julka, S., & Regnier, F. (2004) · Journal of Proteome Research · doi:10.1021/pr0340734 · Cited by 320
Advances in proteomics data analysis and display using an accurate mass and time tag approach
Zimmer, J. S. D., Monroe, M. E., Qian, W., & Smith, R. D. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20071 · Cited by 304
Current trends in quantitative proteomics
Elliott, M. H., Smith, D. S., Parker, C. E., & Borchers, C. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1692 · Cited by 271
Stable isotope labelling methods in mass spectrometry-based quantitative proteomics
Chahrour, O., Cobice, D., & Malone, J. (2015) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2015.04.013 · Cited by 267
Proteomics Analysis of Rat Brain Postsynaptic Density
Li, K. W., Hornshaw, M. P., Van der Schors, R. C., Watson, R., Tate, S., Casetta, B., Jimenez, C. R., Gouwenberg, Y., Gundelfinger, E. D., Smalla, K.-H., et al. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m303116200 · Cited by 246
Majeran, W., Cai, Y., Sun, Q., & van Wijk, K. J. (2005) · The Plant Cell · doi:10.1105/tpc.105.035519 · Cited by 240
“In particular, the cleavable isotope coded affinity tag technique (cICAT) has been successfully employed for comparative proteome analysis (Hansen et al., 2003; Li et al., 2003; Tao and Aebersold, 2003; Conrads et al., 2004).”
MethodProtein Identification by Mass Spectrometry
Baldwin, M. A. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r300012-mcp200 · Cited by 229
“tween hydrogen and deuterium affect the retention times in HPLC whereas the incorporation of (12)C/(13)C labels in peptide pairs has no measurable effect (60).”
BackgroundSelf-citationProtein Profiling with Cleavable Isotope-coded Affinity Tag (cICAT) Reagents
Li, J., Steen, H., & Gygi, S. P. (2003) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m300070-mcp200 · Cited by 218
“Two studies have already appeared using these new reagents (17, 18).”
BackgroundMetabolic Labeling of Proteins for Proteomics
Beynon, R. J., & Pratt, J. M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r400010-mcp200 · Cited by 205
Invited Review: Toxicoproteomics: Proteomics Applied to Toxicology and Pathology
Wetmore, B. A., & Merrick, B. A. (2004) · Toxicologic Pathology · doi:10.1080/01926230490518244 · Cited by 205
“…have rapidly evolved ICAT into a more robust platform by streamlining the chemistries with cleavable linker reagents and improving resolution and identification of peptide pairs by use of 13C-labeled linkers and advanced software (Hansen et al., 2003; Oda et al., 2003; Von Haller et al., 2003).”
BackgroundA Tandem Orthogonal Proteolysis Strategy for High-Content Chemical Proteomics
Speers, A. E., & Cravatt, B. F. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0532842 · Cited by 204
Li, C., Hong, Y., Tan, Y.-X., Zhou, H., Ai, J.-H., Li, S.-J., Zhang, L., Xia, Q.-C., Wu, J.-R., Wang, H.-Y., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m300133-mcp200 · Cited by 185
“After the first generation (2)H-ICAT reagents, the second generation cleavable (13)CICAT reagents provided improved performance (27-29).”
MethodChalkley, R. J., Baker, P. R., Huang, L., Hansen, K. C., Allen, N. P., Rexach, M., & Burlingame, A. L. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.d500002-mcp200 · Cited by 179
“In this particular experiment we sought to understand the changes in protein interactions at the nuclear pore as the yeast progresses through the cell cycle by arresting cells at cell cycle checkpoints and comparing proteins interacting with Gsp1p-GTP using the cleavable ICAT technology (15).”
MethodSelf-citationde Hoog, C. L., & Mann, M. (2004) · Annual Review of Genomics and Human Genetics · doi:10.1146/annurev.genom.4.070802.110305 · Cited by 174
The cancer secretome: a reservoir of biomarkers
Xue, H., Lu, B., & Lai, M. (2008) · Journal of Translational Medicine · doi:10.1186/1479-5876-6-52 · Cited by 170
“Differing from the original reagents, the cICAT reagent uses an acid-cleavable linker and13C or 12C isotopes [53,54].”
MethodGenerally detected proteins in comparative proteomics – A matter of cellular stress response?
Wang, P., Bouwman, F. G., & Mariman, E. C. M. (2009) · PROTEOMICS · doi:10.1002/pmic.200800826 · Cited by 167
“However, MALDI tends to identify larger peptides [16].”
BackgroundVosseller, K., Hansen, K. C., Chalkley, R. J., Trinidad, J. C., Wells, L., Hart, G. W., & Burlingame, A. L. (2005) · PROTEOMICS · doi:10.1002/pmic.200401066 · Cited by 161
Self-citationProtein oxidation: role in signalling and detection by mass spectrometry
Spickett, C. M., & Pitt, A. R. (2012) · Amino Acids · doi:10.1007/s00726-010-0585-4 · Cited by 65
Metadata
- Authors
- Hansen, K. C., Schmitt-Ulms, G., Chalkley, R. J., Hirsch, J., Baldwin, M. A., & Burlingame, A. L.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2003-05
- Volume
- 2
- Issue
- 5
- Pages
- 299-314
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2162311651
- Cited by
- 297
- References
- 35
- FWCI
- 15.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.