Top Down Mass Spectrometry of <60-kDa Proteins from Methanosarcina acetivorans Using Quadrupole FTMS with Automated Octopole Collisionally Activated Dissociation
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
A fragmentation geometry based upon axial acceleration of m/z-selected protein ions into a linear octopole ion trap allowed simultaneous production and external accumulation of fragment ions prior to m/z measurement in a FT mass spectrometer. Improved dynamic range resulting from this octopole collisionally activated dissociation resulted in a 2.5x increase in experimental throughput and a 2x increase in fragment ion matches to gene products identified and characterized in the top down fashion. The acceleration voltage for optimal fragmentation has a m/z and mass dependence, knowledge of which facilitated an automated platform for top down MS/MS on a quadrupole FT hybrid mass spectrometer. Controlled by improved software for data acquisition (e.g. using dynamic exclusion of previously identified species), automated octopole collisionally activated dissociation of samples fractionated using chromatofocusing and reversed-phase liquid chromatography achieved a significant increase in protein identification rate versus previous benchmarks. Also a batch analysis version of ProSight PTM facilitated probability-based identification of intact proteins obtained in a higher throughput fashion. In total, 101 unique proteins (5-59 kDa) were identified from whole cell lysates of Methanosarcina acetivorans grown anaerobically, including the characterization of several mispredicted start sites and biologically relevant mass discrepancies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“those works relied on the in-source fragmentation of all intact proteoforms ionized simultaneously after LC elution, with no m/z filtering and limited possibility of obtaining precursor information.”
From Proton Transfer Charge Reduction Enables High-Throughput Top-Down Analysis of Large Proteoforms (2019) · cites this paper as [48]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Self-citationPeng, J., Elias, J. E., Thoreen, C. C., Licklider, L. J., & Gygi, S. P. (2003) · Journal of Proteome Research · doi:10.1021/pr025556v · Cited by 1,647
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569 · cited 2×
“Poor dynamic range associated with ESI (20) of intact pro-”
BackgroundMass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Protein sequencing by tandem mass spectrometry.
Hunt, D. F., Yates, J. R., Shabanowitz, J., Winston, S., & Hauer, C. R. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.17.6233 · Cited by 1,180 · cited 1×
“This type of fragmentation performed in an octopole is akin to CAD in a triple quadrupole mass spectrometer (40, 41).”
MethodInfrared Multiphoton Dissociation of Large Multiply Charged Ions for Biomolecule Sequencing
Little, D. P., Speir, J. P., Senko, M. W., O'Connor, P. B., & McLafferty, F. W. (1994) · Analytical Chemistry · doi:10.1021/ac00090a004 · Cited by 753 · cited 1×
“ation (26) facilitated development of an automated platform”
BackgroundThe Genome of M. acetivorans Reveals Extensive Metabolic and Physiological Diversity
Galagan, J. E., Nusbaum, C., Roy, A., Endrizzi, M. G., Macdonald, P., FitzHugh, W., Calvo, S., Engels, R., Smirnov, S., Atnoor, D., et al. (2002) · Genome Research · doi:10.1101/gr.223902 · Cited by 623 · cited 4×
“Protein samples from M. acetivorans (C2A), grown on MeOH (46), were produced by two-dimensional fractionation of cell lysates.”
BackgroundMethodSelf-citationZubarev, R. A., Kruger, N. A., Fridriksson, E. K., Lewis, M. A., Horn, D. M., Carpenter, B. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja981948k · Cited by 557
Automated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Peer Reviewed: Top-Down Proteomics
Kelleher, N. L. (2004) · Analytical Chemistry · doi:10.1021/ac0415657 · Cited by 502
Self-citationSenko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 462 · cited 1×
“external accumulation in FT mass spectrometers (32) has led”
BackgroundProteomics by FTICR mass spectrometry: Top down and bottom up
Bogdanov, B., & Smith, R. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20015 · Cited by 447
Syka, J. E. P., Marto, J. A., Bai, D. L., Horning, S., Senko, M. W., Schwartz, J. C., Ueberheide, B., Garcia, B., Busby, S., Muratore, T., et al. (2004) · Journal of Proteome Research · doi:10.1021/pr0499794 · Cited by 348
Yates, J. R., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac401484r · Cited by 324
Self-citationShotgun Proteomics and Biomarker Discovery
McDonald, W. H., & Yates, J. R. (2002) · Disease Markers · doi:10.1155/2002/505397 · Cited by 314
Collisional Activation of Large Multiply Charged Ions Using Fourier Transform Mass Spectrometry
Senko, M. W., Speir, J. P., & McLafferty, F. W. (1994) · Analytical Chemistry · doi:10.1021/ac00090a003 · Cited by 263
Senko, M. W., Canterbury, J. D., Guan, S., & Marshall, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1839::aid-rcm718>3.0.co;2-v · Cited by 259 · cited 2×
“Automation of the MIDAS data station (42) was facilitated by a custom tool command language library with THRASH (47) directed processing (3).”
MethodLarge-scale protein identification using mass spectrometry
Lin, D., Tabb, D. L., & Yates, J. R. (2003) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/s1570-9639(02)00546-0 · Cited by 210
Informatics and multiplexing of intact protein identification in bacteria and the archaea
Meng, F., Cargile, B. J., Miller, L. M., Forbes, A. J., Johnson, J. R., & Kelleher, N. L. (2001) · Nature Biotechnology · doi:10.1038/nbt1001-952 · Cited by 208 · cited 1×
“Improved dynamic range associated with OCAD yielded an average of 14 b/y fragment ions per protein compared with seven b/y fragment ions from previous studies (5, 6), greatly increasing the specificity of intact protein identification.”
ResultSelf-citationLeDuc, R. D., Taylor, G. K., Kim, Y.-B., Januszyk, T. E., Bynum, L. H., Sola, J. V., Garavelli, J. S., & Kelleher, N. L. (2004) · Nucleic Acids Research · doi:10.1093/nar/gkh447 · Cited by 202 · cited 13×
“The 2-fold increase in fragment ion matches increased both the specificity of protein identification and the degree of PTM localization for proteins interrogated in the top down manner.”
MethodSelf-citationProcessing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry
Meng, F., Cargile, B. J., Patrie, S. M., Johnson, J. R., McLoughlin, S. M., & Kelleher, N. L. (2002) · Analytical Chemistry · doi:10.1021/ac020049i · Cited by 183 · cited 4×
“(Milford, MA) followed by reversed-phase (RP) LC (1).”
MethodSelf-citationWeb and Database Software for Identification of Intact Proteins Using “Top Down” Mass Spectrometry
Taylor, G. K., Kim, Y.-B., Forbes, A. J., Meng, F., McCarthy, R., & Kelleher, N. L. (2003) · Analytical Chemistry · doi:10.1021/ac0341721 · Cited by 140 · cited 14×
“The 2-fold increase in fragment ion matches increased both the specificity of protein identification and the degree of PTM localization for proteins interrogated in the top down manner.”
MethodResultSelf-citationJockusch, R. A., Schnier, P. D., Price, W. D., Strittmatter, E. F., Demirev, P. A., & Williams, E. R. (1997) · Analytical Chemistry · doi:10.1021/ac960804q · Cited by 136 · cited 1×
“dissociation kinetics (48)) were stored within the accumulation”
MethodPatrie, S. M., Charlebois, J. P., Whipple, D., Kelleher, N. L., Hendrickson, C. L., Quinn, J. P., Marshall, A. G., & Mukhopadhyay, B. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.04.031 · Cited by 114 · cited 3×
“In a previous study, we described that efficient fragmentation and accumulation of the product ions could be achieved simultaneously in the accumulation region of a Q-FT mass spectrometer instrument by reducing the axial dc potential of the multipole (4).”
MethodSelf-citationNeusüß, C., Pelzing, M., & Macht, M. (2002) · Electrophoresis · doi:10.1002/1522-2683(200209)23:18<3224::aid-elps3224>3.0.co;2-# · Cited by 110
Self-citationRoth, M. J., Forbes, A. J., Boyne, M. T., Kim, Y.-B., Robinson, D. E., & Kelleher, N. L. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500064-mcp200 · Cited by 102 · cited 1×
“possible in an automated fashion (31) but results in diverse”
BackgroundSelf-citationChong, B. E., Yan, F., Lubman, D. M., & Miller, F. R. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.227 · Cited by 97 · cited 3×
“ization of 101 intact proteins from whole cell lysates of Methanosarcina acetivorans (43).”
BackgroundMethodInfluentialForbes, A. J., Patrie, S. M., Taylor, G. K., Kim, Y.-B., Jiang, L., & Kelleher, N. L. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0306575101 · Cited by 94 · cited 1×
“resolution observed from the ALS separation (13).”
Self-citationSannes, K. A., Griffey, R. H., Kruppa, G. H., Speir, J. P., & Hofstadler, S. A. (1998) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19981215)12:23<1957::aid-rcm418>3.0.co;2-m · Cited by 92
Ge, Y., ElNaggar, M., Sze, S. K., Oh, H. B., Begley, T. P., McLafferty, F. W., Boshoff, H., & Barry, C. E. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00913-3 · Cited by 79 · cited 1×
“This agrees with a similar sequence discrepancy found in a groES protein from Mycobacterium tuberculosis (49).”
ResultSerrano, J., Palmeira, C. M., Wallace, K. B., & Kuehl, D. W. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1789::aid-rcm752>3.0.co;2-6 · Cited by 71
Meng, F., Du, Y., Miller, L. M., Patrie, S. M., Robinson, D. E., & Kelleher, N. L. (2004) · Analytical Chemistry · doi:10.1021/ac0354903 · Cited by 67
Self-citationMechanistic studies of multipole storage assisted dissociation
Håkansson, K., Axelsson, J., Palmblad, M., & Håkansson, P. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00144-0 · Cited by 55
Li, Q., Li, L., Rejtar, T., Karger, B. L., & Ferry, J. G. (2005) · Journal of Proteome Research · doi:10.1021/pr049831k · Cited by 52 · cited 1×
“providing insight into differential protein expression (44, 45).”
BackgroundProteome of Methanosarcina a cetivorans Part I: An Expanded View of the Biology of the Cell
Li, Q., Li, L., Rejtar, T., Karger, B. L., & Ferry, J. G. (2005) · Journal of Proteome Research · doi:10.1021/pr049832c · Cited by 45 · cited 1×
“providing insight into differential protein expression (44, 45).”
BackgroundMirgorodskaya, E. E., O’Connor, P. B., & Costello, C. E. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00340-9 · Cited by 42 · cited 1×
“Although amenable to automation (28), increased”
Johnson, J. R., Meng, F., Forbes, A. J., Cargile, B. J., & Kelleher, N. L. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200209)23:18<3217::aid-elps3217>3.0.co;2-k · Cited by 41 · cited 1×
“Over the last 3 years a platform consisting of two-dimensional fractionation (1), an automated (2, 3) quadrupole (Q)(1) FT mass spectrometer (4), and new informatic tools (5–7) has emerged for “top down” analysis (8–11) of intact proteins with”
MethodSelf-citationBelov, M. E., Nikolaev, E. N., Anderson, G., Auberry, K., Harkewicz, R., & Smith, R. D. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00198-7 · Cited by 40
Sannes‐Lowery, K. A., & Hofstadler, S. A. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00110-5 · Cited by 40
Brock, A., Horn, D. M., Peters, E. C., Shaw, C. M., Ericson, C., Phung, Q. T., & Salomon, A. R. (2003) · Analytical Chemistry · doi:10.1021/ac034215d · Cited by 40
From primary structure to function: biological insights from large-molecule mass spectra
Kelleher, N. L. (2000) · Chemistry & Biology · doi:10.1016/s1074-5521(00)00081-8 · Cited by 35
Self-citationCollision induced decomposition of peptides. Choice of collision parameters
Haller, I., Mirza, U. A., & Chait, B. T. (1996) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(96)85613-3 · Cited by 32
FTICR mass spectrometry in proteomics.
Bergquist, J. (2003) · PubMed · Cited by 28
Belov, M. E., Gorshkov, M. V., Udseth, H. R., & Smith, R. D. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00318-x · Cited by 28 · cited 1×
“This lessens the pronounced energy exchange with the rf field that increases ion internal energies leading to dissociation via ion-neutral collisions (33).”
BackgroundStrategies for automating top-down protein analysis with Q-FTICR MS
Patrie, S. M., Robinson, D. E., Meng, F., Du, Y., & Kelleher, N. L. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.02.020 · Cited by 21 · cited 4×
“Automation of the MIDAS data station (42) was facilitated by a custom tool command language library with THRASH (47) directed processing (3).”
MethodSelf-citationAdvanced mass spectrometric methods for the rapid and quantitative characterization of proteomes
Smith, R. (2002) · Comparative and Functional Genomics · doi:10.1002/cfg.159 · Cited by 15
Akashi, S., Takio, K., Matsui, H., Tate, S., & Kainosho, M. (1998) · Analytical Chemistry · doi:10.1021/ac980215f · Cited by 12
McFarland, M. A., Hendrickson, C. L., & Marshall, A. G. (2004) · Analytical Chemistry · doi:10.1021/ac035208s · Cited by 10 · cited 1×
“34), hexapole, (35) and octopole storage devices (22).”
BackgroundPan, C., & Hettich, R. L. (2005) · Analytical Chemistry · doi:10.1021/ac048297x · Cited by 9 · cited 1×
“Attempts to control this process were recently shown for proteins as large as 116 kDa (38, 39).”
BackgroundKeller, K. M., Brodbelt, J. S., Hettich, R. L., & Berkel, G. J. V. (2004) · Journal of Mass Spectrometry · doi:10.1002/jms.602 · Cited by 9 · cited 1×
“Attempts to control this process were recently shown for proteins as large as 116 kDa (38, 39).”
Background
Research works printed but not linked: 1
- Hendrickson, C. L. Quinn., J. P., Emmett, M. R., and Marshall, A. G. (2001) Mass-selective external ion accumulation for Fourier transform ion cy- clotron resonance mass spectrometry, in Proceedings of the 49th Amer- ican Society for Mass Spectrometry Conference on Mass Spectrometry and Allied Topics, Chicago, May 27-31, 2001 (CD-ROM), American So- ciety for Mass Spectrometry, Santa Fe, NM 22.
Cited by
Mapping intact protein isoforms in discovery mode using top-down proteomics
Tran, J. C., Zamdborg, L., Ahlf, D. R., Lee, J. E., Catherman, A. D., Durbin, K. R., Tipton, J. D., Vellaichamy, A., Kellie, J. F., Li, M., et al. (2011) · Nature · doi:10.1038/nature10575 · Cited by 665
“This level of proteome coverage represents the most comprehensive implementation of top-down mass spectrometry so far, with an approximate tenfold increase in identifications of intact proteins for any microbial syste”
Self-citationTop Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“variant of IEX which uses a change in pH rather than ionic strength to achieve elution, has been coupled to off-line RPLC for fractionation of intact proteins from breast cancer [17] and Methanosarcina acetivorans [38].”
BackgroundMethodSelf-citationDecoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503
Self-citationDeconvolution and Database Search of Complex Tandem Mass Spectra of Intact Proteins
Liu, X., Inbar, Y., Dorrestein, P. C., Wynne, C., Edwards, N., Souda, P., Whitelegge, J. P., Bafna, V., & Pevzner, P. A. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.002766 · Cited by 170
Dorrestein, P. C., Bumpus, S. B., Calderone, C. T., Garneau-Tsodikova, S., Aron, Z. D., Straight, P. D., Kolter, R., Walsh, C. T., & Kelleher, N. L. (2006) · Biochemistry · doi:10.1021/bi061169d · Cited by 165
Self-citation
Metadata
- Authors
- Patrie, S. M., Ferguson, J. T., Robinson, D. E., Whipple, D., Rother, M., Metcalf, W. W., & Kelleher, N. L.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Corresponding author
- Kelleher, Neil L.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2006-01
- Volume
- 5
- Issue
- 1
- Pages
- 14-25
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W1974400499
- Cited by
- 62
- References
- 49
- Citations by year
- 2021: 1 · 2020: 1 · 2019: 3 · 2018: 1 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 4 · 2013: 4 · 2012: 6
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by/4.0/ (vor, 5345 d)
- Locations
- Molecular & Cellular Proteomics (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (0134953)
- Division of Chemistry
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- top-down mass spectrometry, Methanosarcina acetivorans, collision-induced dissociation, protein identification, chromatofocusing, reversed-phase liquid chromatography, mass discrepancy, anaerobic bacteria
- MeSH terms
- Amino Acid Sequence, Anaerobiosis, Chromatography, Liquid, Gas Chromatography-Mass Spectrometry, Molecular Sequence Data, Molecular Weight, Protein Processing, Post-Translational, Software, Methanosarcina, Sequence Homology, Amino Acid, Spectroscopy, Fourier Transform Infrared, Archaeal Proteins, Sequence Analysis, Protein, Databases, Protein
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.