Quantitative, Multiplexed Assays for Low Abundance Proteins in Plasma by Targeted Mass Spectrometry and Stable Isotope Dilution
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Biomarker discovery produces lists of candidate markers whose presence and level must be subsequently verified in serum or plasma. Verification represents a paradigm shift from unbiased discovery approaches to targeted, hypothesis-driven methods and relies upon specific, quantitative assays optimized for the selective detection of target proteins. Many protein biomarkers of clinical currency are present at or below the nanogram/milliliter range in plasma and have been inaccessible to date by MS-based methods. Using multiple reaction monitoring coupled with stable isotope dilution mass spectrometry, we describe here the development of quantitative, multiplexed assays for six proteins in plasma that achieve limits of quantitation in the 1-10 ng/ml range with percent coefficients of variation from 3 to 15% without immunoaffinity enrichment of either proteins or peptides. Sample processing methods with sufficient throughput, recovery, and reproducibility to enable robust detection and quantitation of candidate biomarker proteins were developed and optimized by addition of exogenous proteins to immunoaffinity depleted plasma from a healthy donor. Quantitative multiple reaction monitoring assays were designed and optimized for signature peptides derived from the test proteins. Based upon calibration curves using known concentrations of spiked protein in plasma, we determined that each target protein had at least one signature peptide with a limit of quantitation in the 1-10 ng/ml range and linearity typically over 2 orders of magnitude in the measurement range of interest. Limits of detection were frequently in the high picogram/milliliter range. These levels of assay performance represent up to a 1000-fold improvement compared with direct analysis of proteins in plasma by MS and were achieved by simple, robust sample processing involving abundant protein depletion and minimal fractionation by strong cation exchange chromatography at the peptide level prior to LC-multiple reaction monitoring/MS. The methods presented here provide a solid basis for developing quantitative MS-based assays of low level proteins in blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Ross, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Self-citationAbsolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733 · cited 1×
“Monitoring a single transition per peptide has been proposed as being sufficiently specific for peptide quantitation in complex mixtures (18).”
BackgroundZhang, H., Li, X.-J., Martin, D. B., & Aebersold, R. (2003) · Nature Biotechnology · doi:10.1038/nbt827 · Cited by 1,389
Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230 · cited 4×
“concatenated peptide sequences (22, 27)) can be made but requires considerable resources for expression, purification, and characterization of the final protein product.”
BackgroundInfluentialCharacterization of the Low Molecular Weight Human Serum Proteome
Tirumalai, R. S., Chan, K. C., Prieto, D. A., Issaq, H. J., Conrads, T. P., & Veenstra, T. D. (2003) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m300031-mcp200 · Cited by 860
Anderson, N. L., Anderson, N. G., Haines, L. R., Hardie, D. B., Olafson, R. W., & Pearson, T. W. (2004) · Journal of Proteome Research · doi:10.1021/pr034086h · Cited by 804
Toward a Human Blood Serum Proteome
Adkins, J. N., Varnum, S. M., Auberry, K. J., Moore, R. J., Angell, N. H., Smith, R. D., Springer, D. L., & Pounds, J. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200066-mcp200 · Cited by 793
Proteolytic 18O Labeling for Comparative Proteomics: Model Studies with Two Serotypes of Adenovirus
Yao, X., Freas, A., Ramirez, J., Demirev, P. A., & Fenselau, C. (2001) · Analytical Chemistry · doi:10.1021/ac001404c · Cited by 759
Computational prediction of proteotypic peptides for quantitative proteomics
Mallick, P., Schirle, M., Chen, S. S., Flory, M. R., Lee, H., Martin, D., Ranish, J., Raught, B., Schmitt, R., Werner, T., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1275 · Cited by 695
Wang, W., Zhou, H., Lin, H., Roy, S., Shaler, T. A., Hill, L. R., Norton, S., Kumar, P., Anderle, M., & Becker, C. H. (2003) · Analytical Chemistry · doi:10.1021/ac026468x · Cited by 653
Kaji, H., Saito, H., Yamauchi, Y., Shinkawa, T., Taoka, M., Hirabayashi, J., Kasai, K.-I., Takahashi, N., & Isobe, T. (2003) · Nature Biotechnology · doi:10.1038/nbt829 · Cited by 612
Beynon, R. J., Doherty, M. K., Pratt, J. M., & Gaskell, S. J. (2005) · Nature Methods · doi:10.1038/nmeth774 · Cited by 472
Kuhn, E., Wu, J., Karl, J., Liao, H., Zolg, W., & Guild, B. (2004) · PROTEOMICS · doi:10.1002/pmic.200300670 · Cited by 398
Self-citationHigh Sensitivity Detection of Plasma Proteins by Multiple Reaction Monitoring of N-Glycosites
Stahl-Zeng, J., Lange, V., Ossola, R., Eckhardt, K., Krek, W., Aebersold, R., & Domon, B. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700132-mcp200 · Cited by 361
Barr, J. R., Maggio, V. L., Patterson, D. G., Cooper, G. R., Henderson, L. O., Turner, W. E., Smith, S. J., Hannon, W. H., Needham, L. L., & Sampson, E. J. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.10.1676 · Cited by 347
LC/MS applications in drug development
Lee, M. S., & Kerns, E. H. (1999) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1999)18:3/4<187::aid-mas2>3.0.co;2-k · Cited by 339
Shen, Y., Jacobs, J. M., Camp, D. G., Fang, R., Moore, R. J., Smith, R. D., Xiao, W., Davis, R. W., & Tompkins, R. G. (2004) · Analytical Chemistry · doi:10.1021/ac034869m · Cited by 297
A Correlation Algorithm for the Automated Quantitative Analysis of Shotgun Proteomics Data
MacCoss, M. J., Wu, C. C., Liu, H., Sadygov, R., & Yates, J. R. (2003) · Analytical Chemistry · doi:10.1021/ac034790h · Cited by 278
Whiteaker, J. R., Zhao, L., Zhang, H. Y., Feng, L.-C., Piening, B. D., Anderson, L., & Paulovich, A. G. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2006.12.023 · Cited by 270
Barnidge, D. R., Goodmanson, M. K., Klee, G. G., & Muddiman, D. C. (2004) · Journal of Proteome Research · doi:10.1021/pr049963d · Cited by 253
LC/MS applications in drug development.
Lee, M. S., & Kerns, E. H. (1999) · PubMed · Cited by 207
Zhang, H., Yi, E. C., Li, X.-J., Mallick, P., Kelly-Spratt, K. S., Masselon, C. D., Camp, D. G., Smith, R. D., Kemp, C. J., & Aebersold, R. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400090-mcp200 · Cited by 207
Protein fractionation in a multicompartment device using Off‐Gel™ isoelectric focusing
Michel, P. E., Reymond, F., Arnaud, I. L., Josserand, J., Girault, H. H., & Rossier, J. S. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200390030 · Cited by 165
Sun, B., Ranish, J. A., Utleg, A. G., White, J. T., Yan, X., Lin, B., & Hood, L. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t600046-mcp200 · Cited by 165
Desiderio, D. M., & Kai, M. (1983) · Biological Mass Spectrometry · doi:10.1002/bms.1200100806 · Cited by 158
Tang, H., Ali‐Khan, N., Echan, L. A., Levenkova, N., Rux, J. J., & Speicher, D. W. (2005) · PROTEOMICS · doi:10.1002/pmic.200401275 · Cited by 125
Heller, M., Ye, M., Michel, P. E., Morier, P., Stalder, D., Jünger, M. A., Aebersold, R. H., Reymond, F., & Rossier, J. S. (2005) · Journal of Proteome Research · doi:10.1021/pr050193v · Cited by 101
Structural elucidation of drug metabolites by triple-quadrupole mass spectrometry
Perchalski, R. J., Yost, R. A., & Wilder, B. J. (1982) · Analytical Chemistry · doi:10.1021/ac00246a006 · Cited by 101
Shen, Y., Moore, R. J., Zhao, R., Blonder, J., Auberry, D. L., Masselon, C., Paša-Tolić, L., Hixson, K. K., Auberry, K. J., & Smith, R. D. (2003) · Analytical Chemistry · doi:10.1021/ac0300690 · Cited by 97
Lin, S., Shaler, T. A., & Becker, C. H. (2006) · Analytical Chemistry · doi:10.1021/ac060613f · Cited by 87
Moritz, R. L., Clippingdale, A. B., Kapp, E. A., Eddes, J. S., Ji, H., Gilbert, S., Connolly, L. M., & Simpson, R. J. (2005) · PROTEOMICS · doi:10.1002/pmic.200500096 · Cited by 53
Desiderio, D. M., Kai, M., Tanzer, F. S., Trimble, J. W., & Wakelyn, C. (1984) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)89046-4 · Cited by 37
Drug quantitation on a benchtop liquid chromatography-tandem mass spectrometry system
Tiller, P. R., Cunniff, J., Land, A. P., Schwartz, J. C., Jardine, I., Wakefield, M. R., Lopez, L. L., Newton, J. F., Burton, R., Folk, B. M., et al. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)00147-7 · Cited by 30
Cited by
Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302
Peterson, A. C., Russell, J. D., Bailey, D. J., Westphall, M. S., & Coon, J. J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.020131 · Cited by 1,288
Bruderer, R., Bernhardt, O. M., Gandhi, T., Miladinović, S. M., Cheng, L.-Y., Messner, S., Ehrenberger, T., Zanotelli, V., Butscheid, Y., Escher, C., et al. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.044305 · Cited by 1,238
Addona, T. A., Abbatiello, S. E., Schilling, B., Skates, S. J., Mani, D. R., Bunk, D. M., Spiegelman, C. H., Zimmerman, L. J., Ham, A.-J. L., Keshishian, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1546 · Cited by 1,037
Self-citationLess label, more free: Approaches in label‐free quantitative mass spectrometry
Neilson, K. A., Ali, N. A., Muralidharan, S., Mirzaei, M., Mariani, M., Assadourian, G., Lee, A., van Sluyter, S. C., & Haynes, P. A. (2011) · PROTEOMICS · doi:10.1002/pmic.201000553 · Cited by 704
Metadata
- Authors
- Keshishian, H., Addona, T., Burgess, M., Kuhn, E., & Carr, S. A.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2007-12
- Volume
- 6
- Issue
- 12
- Pages
- 2212-2229
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2113766156
- Cited by
- 684
- References
- 38
- FWCI
- 24.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.