Top-down Protein Sequencing and MS3 on a Hybrid Linear Quadrupole Ion Trap-Orbitrap Mass Spectrometer
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Top-down proteomics, the analysis of intact proteins (instead of first digesting them to peptides), has the potential to become a powerful tool for mass spectrometric protein characterization. Requirements for extremely high mass resolution, accuracy, and ability to efficiently fragment large ions have often limited top-down analyses to custom built FT-ICR mass analyzers. Here we explore the hybrid linear ion trap (LTQ)-Orbitrap, a novel, high performance, and compact mass spectrometric analyzer, for top-down proteomics. Protein standards from 10 to 25 kDa were electrosprayed into the instrument using a nanoelectrospray chip. Resolving power of 60,000 was ample for isotope resolution of all protein charge states. We achieved absolute mass accuracies for intact proteins between 0.92 and 2.8 ppm using the "lock mass" mode of operation. Fifty femtomole of cytochrome c applied to the chip resulted in spectra with excellent signal-to-noise ratio and only low attomole sample consumption. Different protein charge states were dissociated in the LTQ, and the sensitivity of the orbitrap allowed routine, high resolution, and high mass accuracy fragment detection. This resulted in unambiguous charge state determination of fragment ions and identification of unmodified and modified proteins by database searching. Protein fragments were further isolated and fragmented in the LTQ followed by analysis of MS(3) fragments in the orbitrap, localizing modifications to part of the sequence and helping to identify the protein with these small peptide-like fragments. Given the ready availability and ease of operation of the LTQ-Orbitrap, it may have significant impact on top-down proteomics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955 · cited 1×
“Almost invariably, proteins are enzymatically degraded to peptides, which are much more amenable to mass spectrometric investigation ( 1 ).”
BackgroundSelf-citationAnalytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868 · cited 1×
“Nanoelectrospray (18, 19) is commonly used in top-down proteomics because it allows”
MethodSelf-citationFemtomole sequencing of proteins from polyacrylamide gels by nano-electrospray mass spectrometry
Wilm, M., Shevchenko, A., Houthaeve, T., Breit, S., Schweigerer, L., Fotsis, T., & Mann, M. (1996) · Nature · doi:10.1038/379466a0 · Cited by 1,680 · cited 1×
“Nanoelectrospray (18, 19) is commonly used in top-down proteomics because it allows”
MethodSelf-citationOlsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,510 · cited 4×
“Mass Accuracy—For high mass accuracy, orbitrap spectra in this study were acquired in the lock mass mode of operation using background PCM ions from the ambient air as internal calibrants as described recently (13).”
BackgroundMethodSelf-citationThe Orbitrap: a new mass spectrometer
Hu, Q., Noll, R. J., Li, H., Makarov, A., Hardman, M., & Graham Cooks, R. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.856 · Cited by 1,333
Clauser, K. R., Baker, P., & Burlingame, A. L. (1999) · Analytical Chemistry · doi:10.1021/ac9810516 · Cited by 1,093 · cited 2×
“ProSight calculates only b- and y-ions, internal fragments were calculated using Protein Prospector ( 14 ) or GPMAW software (15).”
MethodElectrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis
Makarov, A. (2000) · Analytical Chemistry · doi:10.1021/ac991131p · Cited by 1,009 · cited 2×
“analyzer, the orbitrap, invented by Makarov ( 10-12 ).”
MethodPeer Reviewed: Top-Down Proteomics
Kelleher, N. L. (2004) · Analytical Chemistry · doi:10.1021/ac0415657 · Cited by 502
Proteomics by FTICR mass spectrometry: Top down and bottom up
Bogdanov, B., & Smith, R. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20015 · Cited by 447 · cited 1×
“‘top-down proteomics’, intact proteins are ionized, physically fragmented and analyzed in the mass spectrometer (reviewed in ( 2-4 )).”
BackgroundAttomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., & McLafferty, F. W. (1996) · Science · doi:10.1126/science.273.5279.1199 · Cited by 398 · cited 1×
“(20) have reported subattomole detection of 8–30-kDa proteins using capillary electrophore-”
BackgroundProtein identification using sequential ion/ion reactions and tandem mass spectrometry
Coon, J. J., Ueberheide, B., Syka, J. E. P., Dryhurst, D. D., Ausio, J., Shabanowitz, J., & Hunt, D. F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503189102 · Cited by 373 · cited 1×
“A similar fragmentation method, electron transfer dissociation, was recently introduced for ion traps and, in combination with charge state reduction, shows great promise for top-down proteomics on these mass analyzers (6).”
MethodGe, Y., Lawhorn, B. G., ElNaggar, M., Strauss, E., Park, J.-H., Begley, T. P., & McLafferty, F. W. (2002) · Journal of the American Chemical Society · doi:10.1021/ja011335z · Cited by 353 · cited 1×
“In addition, several methods especially useful for fragmentation of whole proteins have been developed for the FT-ICR analyzers, such as infrared multiphoton dissociation, sustained off-resonance irradiation, and, in particular, electron capture dissociation (ECD), which is nonergodic in nature and in some cases can c…”
MethodYates, J. R., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac401484r · Cited by 324
Interfacing the Orbitrap Mass Analyzer to an Electrospray Ion Source
Hardman, M., & Makarov, A. A. (2003) · Analytical Chemistry · doi:10.1021/ac0258047 · Cited by 314 · cited 1×
“analyzer, the orbitrap, invented by Makarov ( 10-12 ).”
MethodOlsen, J. V., & Mann, M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405549101 · Cited by 313 · cited 2×
“Mascot was directed to match only b or y H2O ions (these are the y MS(3) fragments generated from b ion precursors (29)).”
BackgroundSelf-citation‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285 · cited 2×
“‘top-down proteomics’, intact proteins are ionized, physically fragmented and analyzed in the mass spectrometer (reviewed in ( 2-4 )).”
BackgroundMethodSze, S. K., Ge, Y., Oh, H., & McLafferty, F. W. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.251691898 · Cited by 250 · cited 1×
“bonds in a protein (28); however, it suffers from relatively low”
BackgroundLee, S.-W., Berger, S. J., Martinović, S., Paša-Tolić, L., Anderson, G. A., Shen, Y., Zhao, R., & Smith, R. D. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.082119899 · Cited by 184 · cited 2×
“(25) have used a dual ESI source to infuse”
BackgroundBelov, M. E., Gorshkov, M. V., Udseth, H. R., Anderson, G. A., & Smith, R. D. (2000) · Analytical Chemistry · doi:10.1021/ac991360b · Cited by 164 · cited 1×
“(21) have reported low zeptomole detection of”
GPMAW – a software tool for analyzing proteins and peptides
Peri, S., Steen, H., & Pandey, A. (2001) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(01)01954-5 · Cited by 154 · cited 2×
“edu/) (14), or GPMAW (General Protein/Mass Analysis for Windows) (Lighthouse data) (15).”
MethodWeb and Database Software for Identification of Intact Proteins Using “Top Down” Mass Spectrometry
Taylor, G. K., Kim, Y.-B., Forbes, A. J., Meng, F., McCarthy, R., & Kelleher, N. L. (2003) · Analytical Chemistry · doi:10.1021/ac0341721 · Cited by 140 · cited 2×
“edu/) (16) against either the human UniProt or a custom bovine database in “Absolute Mass” mode.”
MethodNew and automated MSn approaches for top-down identification of modified proteins
Zabrouskov, V., Senko, M. W., Du, Y., Leduc, R. D., & Kelleher, N. L. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.08.004 · Cited by 76 · cited 3×
“LTQ under the same conditions normally used for peptide sequencing (7, 8 ). Various charge”
BackgroundMethodInfluentialBruce, J. E., Anderson, G., Brands, M. D., Paša‐Tolić, L., & Smith, R. D. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00096-9 · Cited by 69 · cited 1×
“Although several strategies have been proposed to overcome this effect (23, 24), the best results were obtained when the ion population was well controlled or when internal calibration was performed.”
BackgroundReid, G. E., Stephenson, J. L., & McLuckey, S. A. (2001) · Analytical Chemistry · doi:10.1021/ac015618l · Cited by 64 · cited 1×
“agreement with the ones previously reported for ion trap CID of intact proteins (7, 8, 27 ).”
BackgroundGötmar, G., Zhou, D., Stanley, B. J., & Guiochon, G. (2004) · Analytical Chemistry · doi:10.1021/ac030174+ · Cited by 62
Approaches and Limits for Accurate Mass Characterization of Large Biomolecules
Zubarev, R. A., Demirev, P. A., Håkansson, P., & Sundqvist, B. (1995) · Analytical Chemistry · doi:10.1021/ac00116a028 · Cited by 55 · cited 1×
“was calculated using the top-fitting method described by Zubarev et al ( 22 ), with the cutoff level”
MethodWu, S., Jardine, I., Hancock, W. S., & Karger, B. L. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1609 · Cited by 38 · cited 16×
“However, longer accumulation times and higher AGC MSn target values signif- icantly improved the appearance of the FT-ICR MS2 spectra (not shown).”
BackgroundMethodInfluentialHogan, J. M., Pitteri, S. J., & McLuckey, S. A. (2003) · Analytical Chemistry · doi:10.1021/ac034410s · Cited by 37 · cited 1×
“In contrast, both A and B chains of -crystallin were detected in several forms; A chain was detected as unmodified and modified with one phosphate group; B chain was detected as unmodified and modified with one, two, and three phosphate groups (Fig. 2). Stoichiometries of these modifications were in agreement with tho…”
ResultMarshall, A. G., & Hendrickson, C. L. (2001) · Rapid Communications in Mass Spectrometry · Cited by 27 · cited 1×
“Although several strategies have been proposed to overcome this effect (23, 24), the best results were obtained when the ion population was well controlled or when internal calibration was performed.”
Background
Cited by
Chromatin modifications and their function
Kouzarides, T. (2007) · Cell · doi:10.1016/j.cell.2007.02.005 · Cited by 10,883
“New methodology that uses a top-down proteomics approach (identify protein first and digest subsequently) gives promise that we may, in the future, look at the intact modification pattern of different histones in a given nucleosome ( Macek et al., 2006 ).”
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
“F or p er so na l u se o nl y. Table 2 Approaches in mass spectrometry proteomicsa Prerequisite Advantages Drawbacks Applications Front end Analysis Top down High mass accuracy instruments High sequence coverage Precursor ion charge state limitations Single-protein characterization Ion-exchange chromatography EST LTQ-…”
BackgroundMethodInfluentialMichalski, A., Damoc, E., Hauschild, J.-P., Lange, O., Wieghaus, A., Makarov, A., Nagaraj, N., Cox, J., Mann, M., & Horning, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011015 · Cited by 832
Self-citationMass spectrometry for proteomics
Han, X., Aslanian, A., & Yates, J. R. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2008.07.024 · Cited by 734
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
“The high resolving power and sensitivity of the Orbitrap mass analyzer were quickly shown to facilitate intact proteomic measurements on model proteins smaller than 30 kDa (50).”
Background
Metadata
- Authors
- Macek, B., Waanders, L. F., Olsen, J. V., & Mann, M.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2006-05
- Volume
- 5
- Issue
- 5
- Pages
- 949-958
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2138832989
- Cited by
- 197
- References
- 30
- FWCI
- 10.65
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.