Measurement of energy expenditure
Open accessThe DOI matches its Crossref record; 62 of the 74 references it cites were found in a registry or an index; none of the 50 sources its claims cite is checked for support yet.
Abstract
Measurement of energy expenditure in humans is required to assess metabolic needs, fuel utilisation, and the relative thermic effect of different food, drink, drug and emotional components. Indirect and direct calorimetric and non-calorimetric methods for measuring energy expenditure are reviewed, and their relative value for measurement in the laboratory and field settings is assessed. Where high accuracy is required and sufficient resources are available, an open-circuit indirect calorimeter can be used. Open-circuit indirect calorimeters can employ a mask, hood, canopy or room/chamber for collection of expired air. For short-term measurements, mask, hood or canopy systems suffice. Chamber-based systems are more accurate for the long-term measurement of specified activity patterns but behaviour constraints mean they do not reflect real life. Where resources are limited and/or optimum precision can be sacrificed, flexible total collection systems and non-calorimetric methods are potentially useful if the limitations of these methods are appreciated. The use of the stable isotope technique, doubly labelled water, enables total daily energy expenditure to be measured accurately in free-living subjects. The factorial method for combining activity logs and data on the energy costs of activities can also provide detailed information on free-living subjects.
Overview
CoChat Summary
TL;DR
This paper is a review of methods for measuring human energy expenditure, comparing calorimetric and non-calorimetric approaches in laboratory and field settings. It concludes that the best method depends on the measurement goal and resources, with open-circuit indirect calorimetry for high accuracy in controlled settings and doubly labelled water for total daily energy expenditure in free-living subjects.
Key findings
- Open-circuit indirect calorimeters are recommended when high accuracy is needed; hood/canopy/mask systems are suitable for short-term measurements, while chamber systems are more accurate for long-term specified activity patterns but do not reflect real life.
- Douglas bags can yield very small error under optimal conditions, reported as < 3%, but error can increase substantially with poor maintenance, inaccurate volume/gas measurements, or untrained operators.
- Doubly labelled water measures total daily energy expenditure in free-living subjects over 7–21 days with an error of 6–8%; the paper also notes a major advantage as accurate measurement of total daily energy expenditure with error of ~7%.
- Heart rate monitoring has a reported mean error of 3 ± 20% during light activity; triaxial accelerometers correlate well with total daily energy expenditure measured by doubly labelled water divided by basal metabolic rate.
Methods
- Narrative review of indirect calorimetry, direct calorimetry, non-calorimetric, physiological, and observational methods for measuring energy expenditure in humans.
- Synthesizes measurement characteristics across laboratory and field settings, including reported precision/error, response times, and practical constraints.
- Uses prior studies and technical standards as evidence; no new original data collection or statistical analysis is reported.
Limitations
- The paper explicitly states that many methods have important limitations: chamber-based systems constrain behavior and “do not reflect real life,” heart-rate methods are affected by inter-individual variance and nonlinearity, and activity logs/factorial methods are prone to recording and table-based errors.
- It states that high-quality data on activity-related energy expenditure are sparse, and that some newer technologies (e.g., thermal imaging, global positioning) remain to be determined.
- Evident from the text: this is a review rather than an empirical study, so its conclusions depend on the quality and comparability of the cited literature rather than on a single standardized dataset.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 7 Not valid · 21 Not checked · 46 Own results and interpretations
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Predictably, substantial errors are introduced through inaccurate recall and inadequate data recording.”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim have been checked yet.
In the paper
“These limitations make this technique impractical 46,47 .”
What the sources say
- Not checked yetcites [46]
- Not checked yetcites [47]
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“At best, the mean ( ^ 95% confidence limits) error for estimating energy expenditure using heart rate monitoring is 3 ^ 20% during light activity.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: unclear — It is unclear why the paper says it holds.
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The conceptual limitation of this approach is thatenergyexpenditureandheartratearenotlinearlyrelated for an individual in part because cardiac stroke volume changes with changing heart rate and even posture.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim have been checked yet.
In the paper
“Elimination of administered D2O 18 may be used to estimate carbon dioxide production and energy expenditure.”
What the sources say
- Not checked yetcites [31]
- Not checked yetcites [32]
- Not checked yetcites [33]
- Not checked yetcites [34]
- Not checked yetcites [35]
- Not checked yetcites [36]
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
21 more claims
Create a free account to see all 74 claims and to verify the 50 references still open.
- Probably not a substantial claim. 37
- It may state two separate claims as one. 23
Citations
Cites
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,603
(1996) · PubMed · Cited by 705
Validity of four motion sensors in measuring moderate intensity physical activity
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 527
Assessment of energy expenditure for physical activity using a triaxial accelerometer
BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00016 · Cited by 451
Validity of the Computer Science and Applications, Inc. (CCA) activity monitor
MELANSON, E. L., & FREEDSON, P. S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199506000-00021 · Cited by 416
Validation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374
Energy expenditure of nonexercise activity
Levine, J. A., Schleusner, S. J., & Jensen, M. D. (2000) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/72.6.1451 · Cited by 334
Self-citationCeesay, S. M., Prentice, A. M., Day, K. C., Murgatroyd, P. R., Goldberg, G. R., Scott, W., & Spurr, G. B. (1989) · British Journal of Nutrition · doi:10.1079/bjn19890107 · Cited by 318
Bouten, C. V., Verboeket-van de Venne, W. P., Westerterp, K. R., Verduin, M., & Janssen, J. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.2.1019 · Cited by 223
Variability of some objective measures of physical activity
GRETEBECK, R. J., & MONTOYE, H. J. (1992) · Medicine & Science in sports & Exercise · doi:10.1249/00005768-199210000-00016 · Cited by 212
METABOLIC ASPECTS OF THE CALORIGENIC EFFECT OF THYROID HORMONE IN MAMMALS
SESTOFT, L. (1980) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1980.tb03415.x · Cited by 139
Rietjens, G. J., Kuipers, H., Kester, A. D., & Keizer, H. A. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-14342 · Cited by 126
A method for measuring mechanical work and work efficiency during human activities
Sun, M., & Hill, J. O. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90361-h · Cited by 126
Estimating energy expenditure by heart-rate monitoring without individual calibration
Rennie, K. L., Hennings, S., MITCHELL, J., & Wareham, N. J. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200106000-00013 · Cited by 123
An automated system for assessing metabolic and respiratory function during exercise
Wilmore, J. H., Davis, J. A., & Norton, A. C. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.40.4.619 · Cited by 111
Levine, J. A., Pavlidis, I. T., & Cooper, M. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04936-9 · Cited by 107
Self-citationValidation of the Tracmor triaxial accelerometer system for walking
LEVINE, J. A., BAUKOL, P. A., & WESTERTERP, K. R. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200109000-00024 · Cited by 102
Self-citationSeasonal energy deficiency in Ethiopian rural women.
Ferro-Luzzi, A., Scaccini, C., Taffesse, S., Aberra, B., & Demeke, T. (1990) · PubMed · Cited by 100
Dauncey, M. J., & James, W. P. T. (1979) · British Journal of Nutrition · doi:10.1079/bjn19790084 · Cited by 99
Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure
PAMBIANCO, G., WING, R. R., & ROBERTSON, R. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199012000-00020 · Cited by 93
Sun, M., Reed, G. W., & Hill, J. O. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.6.2686 · Cited by 79
Schutz, Y., Ravussin, É., Diethelm, R., & Jéquier, E. (1982) · PubMed · Cited by 76
Yoshida, T., Nagata, A., Muro, M., Takeuchi, N., & Suda, Y. (1981) · European Journal of Applied Physiology · doi:10.1007/bf00422129 · Cited by 70
Energy balance in man measured by direct and indirect calorimetry
Webb, P. W., Annis, J. F., & Troutman, S. J. (1980) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/33.6.1287 · Cited by 61
Dallosso, H. M., & James, W. P. T. (1984) · British Journal of Nutrition · doi:10.1079/bjn19840071 · Cited by 61
Maffeis, C., Pinelli, L., Zaffanello, M., Schena, F., Iacumin, P., & Schutz, Y. (1995) · PubMed · Cited by 60
Calibration methods in respiratory calorimetry
Young, B. A., Fenton, T. W., & McLean, J. A. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.4.1120 · Cited by 56
KASHIWAZAKI, H. (1999) · Journal of Nutritional Science and Vitaminology · doi:10.3177/jnsv.45.79 · Cited by 53
Calculation of energy expenditure from indirect calorimetry: assessment of the Weir equation.
Cunningham, J. J. (1990) · PubMed · Cited by 52
Westerterp, K. R., & Bouten, C. V. C. (1997) · Zeitschrift für Ernährungswissenschaft · doi:10.1007/bf01617795 · Cited by 51
Human calorimeter with a new type of gradient layer.
Spinnler, G., Jéquier, E., Favre, R., Dolivo, M., & Vannotti, A. (1973) · Journal of Applied Physiology · doi:10.1152/jappl.1973.35.1.158 · Cited by 51
Accuracy of heart-rate monitoring and activity diaries for estimating energy expenditure
Kalkwarf, H. J., Haas, J. D., Belko, A. Z., Roach, R. C., & Roe, D. A. (1989) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/49.1.37 · Cited by 51
Contributions of the doubly labeled water method to studies of energy balance in the Third World
Coward, W. A. (1998) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/68.4.962s · Cited by 50
Coward, W. A., Roberts, S. B., & Cole, T. J. (1988) · PubMed · Cited by 47
Technical description and performance characteristics of a human whole-body calorimeter
Snellen, J. W., Chang, K. S., & Smith, W. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446401 · Cited by 46
Morio, B., Beaufrère, B., Montaurier, C., Verdier, E., Ritz, P., Fellmann, N., Boirie, Y., & Vermorel, M. (1997) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1997.273.2.e321 · Cited by 46
Seliger, V., Dolejš, L., & Karas, V. (1980) · European Journal of Applied Physiology · doi:10.1007/bf00421331 · Cited by 42
Portable respiratory gas collection equipment.
Daniels, J. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.1.164 · Cited by 41
Precision of the doubly labelled water method using the two-point calculation.
Schoeller, D. A., & Pb, T. (1987) · Human nutrition. Clinical nutrition · Cited by 41
Banerjee, B., Khew, K. S., & Saha, N. (1971) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1971.tb00243.x · Cited by 39
Description of a human direct calorimeter, with a note on the energy cost of clerical work
Webster, J. D., Welsh, G., & Garrow, J. S. (1986) · British Journal Of Nutrition · doi:10.1079/bjn19860003 · Cited by 34
Lum, L. C. S., Saville, A., & Venkataraman, S. T. (1998) · Critical Care Medicine · doi:10.1097/00003246-199804000-00029 · Cited by 32
Sujatha, T., Shatrugna, V., Venkataramana, Y., & Begum, N. (2000) · British Journal Of Nutrition · doi:10.1017/s0007114500000635 · Cited by 32
Béghin, L., Budniok, T., Vaksmann, G., Delbecque-Boussard, L., Michaud, L., Turck, D., & Gottrand, F. (2000) · Clinical Nutrition · doi:10.1054/clnu.2000.0147 · Cited by 31
AN APPARATUS FOR STUDYING THE RESPIRATORY EXCHANGE
Benedict, F. G. (1909) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1909.24.3.345 · Cited by 31
An improved estimation of mean body temperature using combined direct calorimetry and thermometry
Snellen, J. W. (2000) · European Journal of Applied Physiology · doi:10.1007/s004210050671 · Cited by 29
A NEW METHOD FOR ESTIMATING THE HEAT PRODUCTION OF ANIMALS
Blaxter, K. L., Brockway, J. M., & Boyne, A. W. (1972) · Quarterly Journal of Experimental Physiology and Cognate Medical Sciences · doi:10.1113/expphysiol.1972.sp002138 · Cited by 29
Energy expenditure studies in military populations using Kofranyi-Michaelis respirometers
Consolazio, C. F. (1971) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/24.12.1431 · Cited by 28
Socially acceptable monitoring instruments (SAMI).
Baker, J. A., Sj, H., & Wolff, H. S. (1967) · PubMed · Cited by 27
Quantitation of energy expenditure by infrared thermography
Shuran, M., & Nelson, R. (1991) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/53.6.1361 · Cited by 25
Indirect Calorimetry in Malnutrition: Nutritional Assessment or Therapeutic Reference?
Kinney, J. M. (1987) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/014860718701100513 · Cited by 22
Tschegg, E. K., Sigmund, A., Veitl, V., et al. (1979) · Metabolism · doi:10.1016/0026-0495(79)90183-5 · Cited by 19
Evaluation of a Non-Invasive Method for the Measurement of Metabolic rate in Humans
Weissman, C., Damask, M. C., ASKANAZI, J., Rosenbaum, S. H., & Kinney, J. M. (1985) · Clinical Science · doi:10.1042/cs0690135 · Cited by 19
A Portable Lightweight Douglas Bag Instrument for Use During Various Types of Exercise
de Groot, G., Schreurs, A. W., & Schenau, G. J. V. I. (1983) · International Journal of Sports Medicine · doi:10.1055/s-2008-1026027 · Cited by 17
deVries, H. A., Burke, R. K., Hopper, R., et al. (1976) · PubMed · Cited by 17
A NEW OPEN AND CLOSED RESPIRATION CHAMBER
AULICK, L. H., Arnhold, H., HANDER, E. H., et al. (1983) · Quarterly Journal of Experimental Physiology · doi:10.1113/expphysiol.1983.sp002730 · Cited by 15
Canopy ventilation monitor for quantitative measurement of ventilation during sleep
Sorkin, B., Rapoport, D. M., Falk, D. B., et al. (1980) · Journal of Applied Physiology · doi:10.1152/jappl.1980.48.4.724 · Cited by 14
Physical activity and anthropometric measurements of obese adolescents.
Mayer, J. (1990) · PubMed · Cited by 14
Kurpad, A. V., Borgonha, S., & Ps, S. (1997) · PubMed · Cited by 12
Oxygen consumption and heart rate during stair climbing.
Fm, B., Wf, F., & Js, W. (1967) · PubMed · Cited by 8
Functional capacity and body composition of different classes of Indian athletes.
Ms, M., Ss, R., Nt, J., et al. (1973) · PubMed · Cited by 6
Deuterium Exchange in Humans: Effect of Gender, Body Composition and Age
Goran, M. I., Poehlman, É. T., Nair, K. S., & Danforth, E. (1993) · Springer eBooks · doi:10.1007/978-1-4899-1268-8_16 · Cited by 5
Research works printed but not linked: 3
- 1973, Energy and Protein Requirements
- Tissot, 1904, Nouvelle methode de mesure et d'inscription du debit et des movements respiratories de l'homme et des animaux, Journal of Physiology and Pathology General, 6, 688
- Douglas, 1911, A method for determining the total respiratory exchange in man, The Journal of Physiology, 42, 17
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
IOC consensus statement on relative energy deficiency in sport (RED-S): 2018 update
Mountjoy, M., Sundgot-Borgen, J. K., Burke, L. M., Ackerman, K. E., Blauwet, C., Constantini, N., Lebrun, C., Lundy, B., Melin, A. K., Meyer, N. L., et al. (2018) · British Journal of Sports Medicine · doi:10.1136/bjsports-2018-099193 · Cited by 883
Animal models of obesity and diabetes mellitus
Kleinert, M., Clemmensen, C., Hofmann, S. M., Moore, M. C., Renner, S., Woods, S. C., Huypens, P., Beckers, J., de Angelis, M. H., Schürmann, A., et al. (2018) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2017.161 · Cited by 832
A guide to analysis of mouse energy metabolism
Tschöp, M. H., Speakman, J. R., Arch, J. R. S., Auwerx, J., Brüning, J. C., Chan, L., Eckel, R. H., Farese, R. V., Galgani, J. E., Hambly, C., et al. (2012) · Nature Methods · doi:10.1038/nmeth.1806 · Cited by 813
“Using direct calorimetry, energy expenditure is assessed by the direct measurement of the body's heat production in a calorimete”
MethodImpact of insufficient sleep on total daily energy expenditure, food intake, and weight gain
Markwald, R. R., Melanson, E. L., Smith, M. R., Higgins, J., Perreault, L., Eckel, R. H., & Wright, K. P. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1216951110 · Cited by 810
“5–2%), the doubly labeled water technique used in prior research (21, 22) provides less sensitive and precise (∼6–8%) estimates of EE (23).”
Method
Metadata
- Authors
- Levine, J. A.
- Affiliations
- Mayo Clinic (US)
- Corresponding author
- Levine, James A
- ORCID
- Levine, James A
- Venue
- Public Health Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 2005-10
- Volume
- 8
- Issue
- 7a
- Pages
- 1123-1132
- ISSN
- 1368-9800 (ISSN-L)
- 1475-2727
- OpenAlex
- W2137403392
- Cited by
- 401
- References
- 74
- Citations by year
- 2026: 16 · 2025: 16 · 2024: 18 · 2023: 26 · 2022: 16 · 2021: 23 · 2020: 21 · 2019: 16 · 2018: 21 · 2017: 28 · 2016: 23 · 2015: 27 · 2014: 25 · 2013: 28 · 2012: 28
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Public Health Nutrition (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK063226, R01DK066270, DK 63226, DK 66270, DK-56650, R01DK056650)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Nutrition and Health Studies
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › thermodynamics and calorimetric analyses
- Keywords
- energy expenditure measurement, indirect calorimetry, direct calorimetry, doubly labeled water, factorial method, free-living energy expenditure, fuel utilization
- MeSH terms
- Basal Metabolism, Calorimetry, Energy Metabolism, Heart Rate, Humans, Indicator Dilution Techniques, Sensitivity and Specificity, Reproducibility of Results, Thermogenesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.