Textile-structured electrodes for electrocardiogram
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
This paper reviews textile-structured electrodes, an interactive textile device, for wearable electrocardiogram (ECG), which will have a profound influence on the health-monitoring practice in the society. A brief description of human cardiac bioelectricity signal using mechanism and acquisition methods by commercial medical electrodes and textile-based electrodes, respectively, is provided. The advantages and disadvantages of these two types of electrodes are discussed. The conduction of ECG signal within the human body, through skin-electrode interface and in electrodes, is also discussed. The ECG signal is picked up usually by commercial medical electrodes, which transform ionic current into electron current from human body to electrode. For ECG recording, there are different types of electrodes available in the market. These electrodes are usually used as disposable types, utilizing hydrogel contact electrolyte and glue, which may cause skin problems in long-term usage. Therefore, textile-structured electrodes are alternative candidates for long-term usage, and wearable due to their intrinsic properties. The designing principles of textile electrodes are presented based on the performance requirements of electrodes. A new evaluation system of textile electrode is presented in the end of the paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2015) · An Einstein Encyclopedia · doi:10.1515/9781400873364-029 · Cited by 2,581
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Physical properties of textile fibres
Morton, W. E., & Hearle, J. W. S. (2008) · Woodhead Publishing Limited eBooks · doi:10.1533/9781845694425 · Cited by 1,530
Bioimpedance and Bioelectricity Basics
(2015) · Elsevier eBooks · doi:10.1016/c2012-0-06951-7 · Cited by 1,175
Medical instrumentation: Application and design
Undar, A., Calhoon, J. H., & Rocha, A. D. (1997) · Control Engineering Practice · doi:10.1016/s0967-0661(97)90030-7 · Cited by 1,015
A Wearable Health Care System Based on Knitted Integrated Sensors
Paradiso, R., Loriga, G., & Taccini, N. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854512 · Cited by 729
A direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 725
Bioimpedance and Bioelectricity Basics
(2008) · Elsevier eBooks · doi:10.1016/b978-0-12-374004-5.x0001-3 · Cited by 462
Marriott's Practical Electrocardiography
Wagner, G. S. (1994) · Cited by 394
Cited by
Chen, M., Gonzalez, S., Vasilakos, A., Cao, H., & Leung, V. C. M. (2011) · Mobile Networks and Applications · doi:10.1007/s11036-010-0260-8 · Cited by 1,352
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
“predict and diagnose cardiovascular diseases [14].”
BackgroundMethodInfluentialNature-Inspired Structural Materials for Flexible Electronic Devices
Liu, Y., He, K., Chen, G., Leow, W. R., & Chen, X. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00291 · Cited by 798
Enabling technologies for wireless body area networks: A survey and outlook
Cao, H., Leung, V., Chow, C., & Chan, H. (2009) · IEEE Communications Magazine · doi:10.1109/mcom.2009.5350373 · Cited by 518
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Flexible Organic Electronics in Biology: Materials and Devices
Liao, C., Zhang, M., Yao, M. Y., Hua, T., Li, L., & Yan, F. (2015) · Advanced Materials · doi:10.1002/adma.201402625 · Cited by 438
Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C.-T., Liao, L.-D., Liu, Y.-H., Wang, I.-J., Lin, B.-S., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336
Advanced Materials for Health Monitoring with Skin‐Based Wearable Devices
Jin, H., Abu‐Raya, Y. S., & Haick, H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700024 · Cited by 317
Wearable and Flexible Textile Electrodes for Biopotential Signal Monitoring: A review
Acar, G., Ozturk, O., Golparvar, A. J., Elboshra, T. A., Böhringer, K., & Yapici, M. K. (2019) · Electronics · doi:10.3390/electronics8050479 · Cited by 315
Cognition in action: imaging brain/body dynamics in mobile humans
Gramann, K., Gwin, J. T., Ferris, D. P., Oie, K., Jung, T.-P., Lin, C.-T., Liao, L.-D., & Makeig, S. (2011) · Reviews in the Neurosciences · doi:10.1515/rns.2011.047 · Cited by 302
Developing residential wireless sensor networks for ECG healthcare monitoring
Dey, N., Ashour, A. S., Shi, F., Fong, S. J., & Sherratt, R. S. (2017) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2017.015063 · Cited by 283
Graphene-clad textile electrodes for electrocardiogram monitoring
Yapici, M. K., Alkhidir, T., Samad, Y. A., & Liao, K. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.111 · Cited by 239
Wearable silver nanowire dry electrodes for electrophysiological sensing
Myers, A. C., Huang, H., & Zhu, Y. (2015) · RSC Advances · doi:10.1039/c4ra15101a · Cited by 231
Liao, L.-D., Wang, I.-J., Chen, S.-F., Chang, J.-Y., & Lin, C.-T. (2011) · Sensors · doi:10.3390/s110605819 · Cited by 181
“Recently, fabric-based electrodes have been used to measure biopotential signals [20-24].”
Biosensor Technologies for Augmented Brain–Computer Interfaces in the Next Decades
Liao, L.-D., Lin, C.-T., McDowell, K., Wickenden, A. E., Gramann, K., Jung, T.-P., Ko, L.-W., & Chang, J.-Y. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2184829 · Cited by 169
Nanomaterial-Enabled Dry Electrodes for Electrophysiological Sensing: A Review
Yao, S., & Zhu, Y. (2016) · JOM · doi:10.1007/s11837-016-1818-0 · Cited by 166
Intelligent Medical Garments with Graphene-Functionalized Smart-Cloth ECG Sensors
Yapici, M., & Alkhidir, T. (2017) · Sensors · doi:10.3390/s17040875 · Cited by 166
“In contact electrodes, direct physical coupling is established between the skin and the electrode, where the coupling efficiency may be further enhanced by the presence of sweat or moisture [4,5].”
BackgroundNoncontact Wearable Wireless ECG Systems for Long-Term Monitoring
Majumder, S., Chen, L., Marinov, O., Chen, C.-H., Mondal, T., & Deen, M. J. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2840336 · Cited by 165
“One may find several early implementations of textile electrodes in [36]–[39].”
Background
Metadata
- Authors
- Xu, P. J., Zhang, H., & Tao, X. M.
- Venue
- Textile Progress
- Publisher
- Informa UK Limited
- Published
- 2008-12-18
- Volume
- 40
- Issue
- 4
- Pages
- 183-213
- ISSN
- 0040-5167 (ISSN-L)
- 1754-2278
- OpenAlex
- W2044862634
- Cited by
- 168
- References
- 42
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.