Techniques of Body Composition Assessment: A Review of Laboratory and Field Methods
The DOI matches its Crossref record; 98 of the 98 references it cites were found in a registry or an index.
Abstract
Body composition is one of the major health-related components of fitness. Thus, it is important for health and fitness professionals to have a general understanding of the most commonly used techniques for assessing body composition. This review presents the developmental background and underlying principles and theory of four laboratory (hydrodensitometry, air displacement plethysmography, isotope dilution, and dual-energy x-ray absorptiometry) and four field (bioelectrical impedance analysis, near-infrared interactance, skinfolds, and anthropometry) methods of body composition assessment. In addition to a description of the methods, the validity, and reliability, strengths, and limitations of each measurement tool are examined. Highlights of the laboratory methods include the relatively new Bod Pod air displacement device, which is a promising assessment tool more convenient than hydrodensitometry but still lacking substantial validity testing and the ability of dual-energy x-ray absorptiometry to measure regional composition making it an attractive method for clinicians. Advancements in segmental and multifrequency bioelectrical impedance for compartmental analysis have enhanced the value of this field method, but research continues to show that commercially available near-infrared interactance units are invalid. With this knowledge, the clinician and researcher should be able to make an informed decision regarding the most appropriate measurement device for their body composition assessments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A formula to estimate the approximate surface area if height and weight be known. 1916.
Bois, D. D., & Bois, E. F. D. (1989) · PubMed · Cited by 5,706
The American Journal of Physiology
(1899) · The American Naturalist · doi:10.1086/277182 · Cited by 5,654
Du BOIS, D. (1916) · Archives of Internal Medicine · doi:10.1001/archinte.1916.00080130010002 · Cited by 4,342
Generalized equations for predicting body density of men
Jackson, A. S., & Pollock, M. L. (1978) · British Journal of Nutrition · doi:10.1079/bjn19780152 · Cited by 3,201
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Generalized equations for predicting body density of women
JACKSON, A. S., POLLOCK, M. L., & WARD, A. (1980) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198023000-00009 · Cited by 1,847
Medicine and Science in Sports and Exercise-1980
Tipton, C. M. (1980) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198021000-00001 · Cited by 1,631
Techniques for Measuring Body Composition
(1961) · National Academies Press eBooks · doi:10.17226/21603 · Cited by 1,611
Mazess, R., Barden, H., Bisek, J., & Hanson, J. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.6.1106 · Cited by 1,476
ACSM's guidelines for exercise testing and prescription
Kenney, W. L., Humphrey, R. H., Bryant, C. X., & Mahler, D. A. (1995) · Williams & Wilkins eBooks · Cited by 1,475
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Assessing Adiposity: A Scientific Statement From the American Heart Association
Cornier, M.-A., Després, J.-P., Davis, N., Grossniklaus, D. A., Klein, S., Lamarche, B., Lopez-Jimenez, F., Rao, G., St-Onge, M.-P., Towfighi, A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318233bc6a · Cited by 945
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
“4194 in [97], when using the 40 K isotope [98] as a reference method on dialyzed patients and 120 healthy subjects.”
MethodA Framework for Understanding the Training Process Leading to Elite Performance
Smith, D. J. (2003) · Sports Medicine · doi:10.2165/00007256-200333150-00003 · Cited by 526
Krieger, J. W., Sitren, H. S., Daniels, M. J., & Langkamp-Henken, B. (2006) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/83.2.260 · Cited by 466
Measures of body composition in blacks and whites: a comparative review
Wagner, D. R., & Heyward, V. H. (2000) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/71.6.1392 · Cited by 397
Self-citationInternational society of sports nutrition position stand: diets and body composition
Aragon, A. A., Schoenfeld, B. J., Wildman, R., Kleiner, S., VanDusseldorp, T., Taylor, L., Earnest, C. P., Arciero, P. J., Wilborn, C., Kalman, D. S., et al. (2017) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-017-0174-y · Cited by 301
“An excellent review by Wagner and Hayward [10] concludes the following: “There is no single method which is ‘best;’ rather, the clinician or researcher must weigh the practical considerations of their assessment needs with the limitations of the methods.””
Body fat and fat-free mass and all-cause mortality
Bigaard, J., Frederiksen, K., Tjønneland, A., Thomsen, B. L., Overvad, K., Heitmann, B. L., & Sørensen, T. I. A. (2004) · Obesity Research · doi:10.1038/oby.2004.131 · Cited by 288
Ultrasound as a Tool to Assess Body Fat
Wagner, D. R. (2013) · Journal of Obesity · doi:10.1155/2013/280713 · Cited by 252
Self-citationComparison of anthropometry to DXA: a new prediction equation for men
Ball, S. D., Altena, T. S., & Swan, P. D. (2004) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602003 · Cited by 173
“In fact, with the advent of more modern and advanced technological means of assessing fatness, the 2C model is now considered an obsolete criterion measure by some (Wagner & Heyward, 1999).”
BackgroundAssessment of Nutrient Status in Athletes and the Need for Supplementation
Larson-Meyer, D. E., Woolf, K., & Burke, L. (2018) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2017-0338 · Cited by 165
“As outlined in Table 3, commonly-used body composition analysis techniques (Meyer et al., 2013) have inherent limitations that include methodological assumptions and measurement errors (Gibson, 2005; Wagner & Heyward, 1999).”
MethodKendler, D. L., Borges, J. L. C., Fielding, R. A., Itabashi, A., Krueger, D., Mulligan, K., Camargos, B. M., Sabowitz, B., Wu, C.-H., Yu, E. W., et al. (2013) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2013.08.020 · Cited by 121
Yapici, H., Gülü, M., Yagin, F. H., Ugurlu, D., Comertpay, E., Eroglu, O., Kocoğlu, M., Aldhahi, M. I., Karayigit, R., & Badri AL-Mhanna, S. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1148494 · Cited by 13
Grove, J., & Hung, Y.-J. (2017) · Journal of Physical Therapy and Sports Medicine · doi:10.35841/physical-therapy.1.1.5-11 · Cited by 6
“Results from DXA also have a strong correlation to the data examined with magnetic resonance imaging, computed tomography, and multi-compartmental models [23-26,22].”
Walker, J. K., Dillard, C. C., Gonzalez, D. E., Waldman, H. S., & McAllister, M. J. (2025) · Stress · doi:10.1080/10253890.2024.2449098 · Cited by 4
Metadata
- Authors
- Wagner, D. R., & Heyward, V. H.
- Venue
- Research Quarterly for Exercise and Sport
- Publisher
- Informa UK Limited
- Published
- 1999-06
- Volume
- 70
- Issue
- 2
- Pages
- 135-149
- ISSN
- 0034-5377 (ISSN-L)
- 0270-1367
- 2168-3824
- OpenAlex
- W2104148327
- Cited by
- 209
- References
- 98
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.