CoChat

Validity of heart rate measurements by the Garmin Forerunner 225 at different walking intensities

Open access
Claes, Jomme, Buys, Roselien, Avila, Andrea, Finlay, Dewar, Kennedy, Alan, Guldenring, Daniel, Budts, Werner, Cornelissen, Véronique · 2017 · Journal of Medical Engineering & Technology
Cited by 49

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

The accuracy of wrist worn heart rate monitors based on photoplethysmography (PPG) is not fully clinically accepted. Therefore, we aimed to validate heart rate measurements of a commercially available PPG heart rate monitor, i.e. the Garmin Forerunner® 225. Twelve healthy volunteers (six women; mean age: 28 years) performed a treadmill protocol consisting of: five minutes sitting, five minutes standing, 10 minutes walking at 4 km/h, 10 minutes walking at a gradient of 5% and intensity of 4–6 metabolic equivalents (METs), 10 minutes walking at a gradient of 8% and intensity of seven METs or more. Walking speeds were individually determined. Walking bouts were separated by a standardised five minute rest period. Heart rate was measured as the average of the last three minutes standing and of each walking bout. A three lead patch-based electrocardiogram (ECG; Zensor®) was used as criterion method. Statistical analyses included Pearson’s correlation (r), paired t-tests, root mean squared error (RMSE) and Bland?Altman plots. The mean values per three minutes of every condition did not differ significantly between the Garmin Forerunner® 225 and the Zensor®. RMSE was 3.01 beats per minute (bpm) or 2.89%. The Bland–Altman bias was 1.57 bpm. Limits of agreement (LoA) were wide, ranging from 32.53 to 29.40 bpm. However, Pearson’s r ranged from 0.650 to 0.868 suggesting moderate to strong validity. Generally, mean heart rates, r values, RMSE and the Bland–Altman bias indicated good overall agreement in this sample of healthy adults, but wide LoA are making it difficult to trust individual measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/03091902.2017.1333166

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

Metadata

Authors
Claes, J., Buys, R., Avila, A., Finlay, D., Kennedy, A., Guldenring, D., Budts, W., & Cornelissen, V.
Venue
Journal of Medical Engineering & Technology
Published
2017-07-04
Volume
41
Issue
6
Pages
480-485
ISSN
  • 0309-1902 (ISSN-L)
  • 1464-522X
OpenAlex
W2725379293
Cited by
49
References
13
FWCI
1.98
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.