Performance assessment of new-generation Fitbit technology in deriving sleep parameters and stages
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We compared performance in deriving sleep variables by both Fitbit Charge 2™, which couples body movement (accelerometry) and heart rate variability (HRV) in combination with its proprietary interpretative algorithm (IA), and standard actigraphy (Motionlogger® Micro Watch Actigraph: MMWA), which relies solely on accelerometry in combination with its best performing 'Sadeh' IA, to electroencephalography (EEG: Zmachine® Insight+ and its proprietary IA) used as reference. We conducted home sleep studies on 35 healthy adults, 33 of whom provided complete datasets of the three simultaneously assessed technologies. Relative to the Zmachine EEG method, Fitbit showed an overall Kappa agreement of 54% in distinguishing wake/sleep epochs and sensitivity of 95% and specificity of 57% in detecting sleep epochs. Fitbit, relative to EEG, underestimated sleep onset latency (SOL) by ~11 min and overestimated sleep efficiency (SE) by ~4%. There was no statistically significant difference between Fitbit and EEG methods in measuring wake after sleep onset (WASO) and total sleep time (TST). Fitbit showed substantial agreement with EEG in detecting rapid eye movement and deep sleep, but only moderate agreement in detecting light sleep. The MMWA method showed 51% overall Kappa agreement with the EEG one in detecting wake/sleep epochs, with sensitivity of 94% and specificity of 53% in detecting sleep epochs. MMWA, relative to EEG, underestimated SOL by ~10 min. There was no significant difference between Fitbit and MMWA methods in amount of bias in estimating SOL, WASO, TST, and SE; however, the minimum detectable change (MDC) per sleep variable with Fitbit was better (smaller) than with MMWA, respectively, by ~10 min, ~16 min, ~22 min, and ~8%. Overall, performance of Fitbit accelerometry and HRV technology in conjunction with its proprietary IA to detect sleep vs. wake episodes is slightly better than wrist actigraphy that relies solely on accelerometry and best performing Sadeh IA. Moreover, the smaller MDC of Fitbit technology in deriving sleep parameters in comparison to wrist actigraphy makes it a suitable option for assessing changes in sleep quality over time, longitudinally, and/or in response to interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 1×
“If a significant relationship between differences and magnitude of mean values was detected, we used the regression approach for nonuniform differences to generate the Bland–Altman plot (Bland and Altman 1999).”
MethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Activity-Based Sleep-Wake Identification: An Empirical Test of Methodological Issues
Sadeh, A., Sharkey, M., & Carskadon, M. A. (1994) · Sleep · doi:10.1093/sleep/17.3.201 · Cited by 1,487
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · cited 1×
“Nonetheless, persisting major concern of the public and medical professionals is accuracy (Baron et al. 2018; Evenson et al. 2015; Feehan et al. 2018).”
BackgroundAccuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616 · cited 1×
“Nonetheless, persisting major concern of the public and medical professionals is accuracy (Baron et al. 2018; Evenson et al. 2015; Feehan et al. 2018).”
BackgroundStranges, S., Tigbe, W., Gómez-Olivé, F. X., Thorogood, M., & Kandala, N.-B. (2012) · Sleep · doi:10.5665/sleep.2012 · Cited by 592 · cited 2×
“…because poor quality and/or insufficient quantity of sleep is problematic for some 50–70 million adults in the USA (Colten and Altevogt 2006) and million others globally (Groeger et al. 2004; Knutson et al. 2010; Stranges et al. 2012), with consequent negative impact on productivity and health.”
BackgroundThe American Academy of Sleep Medicine Inter-scorer Reliability Program: Sleep Stage Scoring
Rosenberg, R. S., & Van Hout, S. (2013) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2350 · Cited by 456
Accuracy of Wristband Fitbit Models in Assessing Sleep: Systematic Review and Meta-Analysis
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Journal of Medical Internet Research · doi:10.2196/16273 · Cited by 446 · cited 11×
“Furthermore, Fitbit technology provides an accurate assessment of heart rate during sleep (de Zambotti et al. 2016; Haghayegh et al. 2019a), which is considered to be an important biomarker of cardiovascular disease risk (Hermida et al. 2018; Palatini and Julius 1997; Roush et al. 2014).”
BackgroundMethodResultInfluentialSelf-citationMovement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301
Roush, G. C., Fagard, R. H., Salles, G. F., Pierdomenico, S. D., Reboldi, G., Verdecchia, P., Eguchi, K., Kario, K., Hoshide, S., Polonia, J., et al. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000355 · Cited by 272 · cited 1×
“Furthermore, Fitbit technology provides an accurate assessment of heart rate during sleep (de Zambotti et al. 2016; Haghayegh et al. 2019a), which is considered to be an important biomarker of cardiovascular disease risk (Hermida et al. 2018; Palatini and Julius 1997; Roush et al. 2014).”
Backgroundde Zambotti, M., Baker, F. C., Willoughby, A. R., Godino, J. G., Wing, D., Patrick, K., & Colrain, I. M. (2016) · Physiology & Behavior · doi:10.1016/j.physbeh.2016.03.006 · Cited by 222 · cited 1×
“Furthermore, Fitbit technology provides an accurate assessment of heart rate during sleep (de Zambotti et al. 2016; Haghayegh et al. 2019a), which is considered to be an important biomarker of cardiovascular disease risk (Hermida et al. 2018; Palatini and Julius 1997; Roush et al. 2014).”
BackgroundBeattie, Z., Oyang, Y., Statan, A., Ghoreyshi, A., Pantelopoulos, A., Russell, A., & Heneghan, C. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa9047 · Cited by 198 · cited 3×
“The proprietary software algorithm, utilizing as input accelerometry and HRV data, was derived by the Fitbit Company through sleep laboratory studies of normal sleepers and with the aid of machine learning (Beattie et al. 2017).”
BackgroundMethodInfluentialBaron, K. G., Duffecy, J., Berendsen, M. A., Cheung Mason, I., Lattie, E. G., & Manalo, N. C. (2018) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2017.12.002 · Cited by 186 · cited 1×
“Nonetheless, persisting major concern of the public and medical professionals is accuracy (Baron et al. 2018; Evenson et al. 2015; Feehan et al. 2018).”
BackgroundHaghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Chronobiology International · doi:10.1080/07420528.2019.1679826 · Cited by 38 · cited 12×
“Furthermore, Fitbit technology provides an accurate assessment of heart rate during sleep (de Zambotti et al. 2016; Haghayegh et al. 2019a), which is considered to be an important biomarker of cardiovascular disease risk (Hermida et al. 2018; Palatini and Julius 1997; Roush et al. 2014).”
BackgroundMethodResultInfluential
Cited by
Zheng, N. S., Annis, J., Master, H., Han, L., Gleichauf, K., Ching, J. H., Nasser, M., Coleman, P., Desine, S., Ruderfer, D. M., et al. (2024) · Nature Medicine · doi:10.1038/s41591-024-03155-8 · Cited by 194
“The Fitbit algorithms have been evaluated against gold-standard polysomnograms in many studies 14–20, 43, 44 .”
MethodHaghayegh, S., Kang, H.-A., Khoshnevis, S., Smolensky, M. H., & Diller, K. R. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab86d6 · Cited by 152
Self-citationHaghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Chronobiology International · doi:10.1080/07420528.2019.1679826 · Cited by 38
Stine, J. G., Schreibman, I., Navabi, S., Kang, M., Dahmus, J., Soriano, C., Rivas, G., Hummer, B., Beyer, M., Tressler, H., et al. (2020) · Contemporary Clinical Trials Communications · doi:10.1016/j.conctc.2020.100560 · Cited by 19
“Sleep quality Sleep quality is recorded by Fitbit Charge HR2 with established validated cutoffs [73].”
Method
Metadata
- Authors
- Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J.
- Venue
- Chronobiology International
- Publisher
- Informa UK Limited
- Published
- 2019-11-13
- Volume
- 37
- Issue
- 1
- Pages
- 47-59
- ISSN
- 0742-0528 (ISSN-L)
- 1525-6073
- OpenAlex
- W2986003490
- Cited by
- 74
- References
- 15
- FWCI
- 8.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.