Measures of sleep and cardiac functioning during sleep using a multi-sensory commercially-available wristband in adolescents

Open access
de Zambotti, Massimiliano, Baker, Fiona C., Willoughby, Adrian R., Godino, Job G., Wing, David, Patrick, Kevin, Colrain, Ian M.·2016·Physiology & Behavior

Abstract

To validate measures of sleep and heart rate (HR) during sleep generated by a commercially-available activity tracker against those derived from polysomnography (PSG) in healthy adolescents. Sleep data were concurrently recorded using FitbitChargeHR™ and PSG, including electrocardiography (ECG), during an overnight laboratory sleep recording in 32 healthy adolescents (15 females; age, mean±SD: 17.3±2.5years). Sleep and HR measures were compared between FitbitChargeHR™ and PSG using paired t-tests and Bland-Altman plots. Epoch-by-epoch analysis showed that FitbitChargeHR™ had high overall accuracy (91%), high sensitivity (97%) in detecting sleep, and poor specificity (42%) in detecting wake on a min-to-min basis. On average, FitbitChargeHR™ significantly but negligibly overestimated total sleep time by 8min and sleep efficiency by 1.8%, and underestimated wake after sleep onset by 5.6min (p<0.05). Within FitbitChargeHR™ epochs of sleep, the average HR was 59.3±7.5bpm, which was significantly but negligibly lower than that calculated from ECG (60.2±7.6bpm, p<0.001), with no change in mean discrepancies throughout the night. FitbitChargeHR™ showed good agreement with PSG and ECG in measuring sleep and HR during sleep, supporting its use in assessing sleep and cardiac function in healthy adolescents. Further validation is needed to assess its reliability over prolonged periods of time in ecological settings and in clinical populations.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.physbeh.2016.03.006

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Some studies have used the gold-standard reference method of electrocardiogram, which directly measures heart rate via electrical impulses from the heart and is used for clinical accuracy.

    “Although some studies have attempted to address wearable HR accuracy using the gold-standard reference method of ECG, which directly measures HR via electrical impulses from the heart and is used for clinical accuracy38–44”
  • On average, wearables slightly and negligibly underestimate absolute heart rate (−0.9 to −7.2 bpm) compared with gold-standard electrocardiogram.

    “Current research verifying wearables to the gold-standard ECG, which uses electrodes to directly measure cardiac muscular contractions from electrical activity of the heart, have shown that on average wearables slightly and negligibly underestimate (−0.9 to −7.2 bpm) absolute HR40,41,44,52”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
de Zambotti, M., Baker, F. C., Willoughby, A. R., Godino, J. G., Wing, D., Patrick, K., & Colrain, I. M.
Affiliations
  • SRI International (US)
  • University of California San Diego (US)
Corresponding author
Colrain, Ian M.
Venue
Physiology & Behavior
Publisher
Elsevier BV
Published
2016-05
Volume
158
Pages
143-149
ISSN
0031-9384 (ISSN-L)
OpenAlex
W2295749803
Cited by
222
References
40
Citations by year
2026: 6 · 2025: 14 · 2024: 28 · 2023: 20 · 2022: 17 · 2021: 32 · 2020: 43 · 2019: 31 · 2018: 14 · 2017: 13 · 2016: 4
FWCI
29.34
Type
journal article
Language
en
Open access
Locations
  • Physiology & Behavior (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institute on Alcohol Abuse and Alcoholism (U01AA021696, U24AA021695)
Topics
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
Keywords
wearable activity trackers, wristband, sleep monitoring, heart rate during sleep, adolescents, polysomnography validation, electrocardiogram, total sleep time, sleep efficiency, wake after sleep onset
MeSH terms
Adolescent, Electrocardiography, Female, Heart Rate, Humans, Male, Sleep, Time Factors, Wakefulness, Polysomnography, Young Adult, Actigraphy, Wireless Technology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review