Absolute frequency measurement of the optical clock transition in with an uncertainty of using a frequency link to international atomic time
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
The highly forbidden 2S1/2→2F7/2 electric octupole transition in 171Yb+ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical transition, performed using a frequency link to International Atomic Time to provide traceability to the SI second. The 171Yb+ optical frequency standard was operated for 76% of a 25-day period, with the absolute frequency measured to be 642 121 496 772 645.14(26) Hz. The fractional uncertainty of 4.0×10-16 is comparable to that of the best previously reported measurement, which was made by a direct comparison to local caesium primary frequency standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationUltrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
High-Accuracy Optical Clock Based on the Octupole Transition inYb+171
Huntemann, N., Okhapkin, M., Lipphardt, B., Weyers, S., Tamm, C., & Peik, E. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.090801 · Cited by 241
Sub-Hertz Optical Frequency Comparisons between Two TrappedYb+171Ions
Schneider, T., Peik, E., & Tamm, C. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.230801 · Cited by 204
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Frequency Comparison of TwoCa+40Optical Clocks with an Uncertainty at the10−17Level
Huang, Y., Guan, H., Liu, P., Bian, W., Ma, L., Liang, K., Li, T., & Gao, K. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.013001 · Cited by 106
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
Agreement between two88Sr+optical clocks to 4 parts in 1017
Barwood, G. P., Huang, G., Klein, H. A., Johnson, L. A. M., King, S. A., Margolis, H. S., Szymaniec, K., & Gill, P. (2014) · Physical Review A · doi:10.1103/physreva.89.050501 · Cited by 90
Self-citationComparing a mercury optical lattice clock with microwave and optical frequency standards
Tyumenev, R., Favier, M., Bilicki, S., Bookjans, E., Targat, R. L., Lodewyck, J., Nicolodi, D., Coq, Y. L., Abgrall, M., Guéna, J., et al. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/11/113002 · Cited by 85
Park, C. Y., Yu, D.-H., Lee, W.-K., Park, S. E., Kim, E. B., Lee, S. K., Cho, J. W., Yoon, T. H., Mun, J., Park, S. J., et al. (2013) · Metrologia · doi:10.1088/0026-1394/50/2/119 · Cited by 74
King, S. A., Godun, R. M., Webster, S. A., Margolis, H. S., Johnson, L. A. M., Szymaniec, K., Baird, P. E. G., & Gill, P. (2012) · New Journal of Physics · doi:10.1088/1367-2630/14/1/013045 · Cited by 63
Self-citationAtomic time-keeping from 1955 to the present
Guinot, B., & Arias, E. F. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s04 · Cited by 60
Optical-to-microwave frequency comparison with fractional uncertainty of 10-15
Stalnaker, J. E., Diddams, S. A., Fortier, T. M., Kim, K., Hollberg, L. W., Bergquist, J., Itano, W. M., Delany, M. J., Lorini, L., Oskay, W. H., et al. (2007) · Applied Physics B · doi:10.1007/s00340-007-2762-z · Cited by 59
Pizzocaro, M., Thoumany, P., Rauf, B., Bregolin, F., Milani, G., Clivati, C., Costanzo, G. A., Levi, F., & Calonico, D. (2017) · Metrologia · doi:10.1088/1681-7575/aa4e62 · Cited by 58
Hachisu, H., Petit, G., Nakagawa, F., Hanado, Y., & Ido, T. (2017) · Optics Express · doi:10.1364/oe.25.008511 · Cited by 53
Akamatsu, D., Inaba, H., Hosaka, K., Yasuda, M., Onae, A., Suzuyama, T., Amemiya, M., & Hong, F.-L. (2014) · Applied Physics Express · doi:10.7567/apex.7.012401 · Cited by 49
Intermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
Hachisu, H., & Ido, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.112401 · Cited by 48
Uncertainty of a frequency comparison with distributed dead time and measurement interval offset
Yu, D.-H., Weiss, M., & Parker, T. E. (2007) · Metrologia · doi:10.1088/0026-1394/44/1/014 · Cited by 44
Margolis, H. S., & Gill, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/5/628 · Cited by 40
Self-citationEvaluating the performance of the NPL femtosecond frequency combs: agreement at the 10−21level
Johnson, L. A. M., Gill, P., & Margolis, H. S. (2015) · Metrologia · doi:10.1088/0026-1394/52/1/62 · Cited by 39
Self-citationA single-ion trap with minimized ion–environment interactions
Nisbet-Jones, P. B. R., King, S. A., Jones, J. M., Godun, R. M., Baynham, C. F. A., Bongs, K., Doležal, M., Balling, P., & Gill, P. (2016) · Applied Physics B · doi:10.1007/s00340-016-6327-x · Cited by 36
Self-citationHachisu, H., Petit, G., & Ido, T. (2017) · Applied Physics B · doi:10.1007/s00340-016-6603-9 · Cited by 31
Frequency Comparison of $^{171}{\text {Yb}}^+$ Ion Optical Clocks at PTB and NPL via GPS PPP
Leute, J., Huntemann, N., Lipphardt, B., Tamm, C., Nisbet-Jones, P. B. R., King, S. A., Godun, R. M., Jones, J. M., Margolis, H. S., Whibberley, P. B., et al. (2016) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2016.2524988 · Cited by 29
Self-citationAbsolute frequency measurement of the 88 Sr + clock transition using a GPS link to the SI second
Dubé, P., Bernard, J. E., & Gertsvolf, M. (2017) · Metrologia · doi:10.1088/1681-7575/aa5e60 · Cited by 28
International timescales with optical clocks (ITOC)
Margolis, H. S., Godun, R. M., Gill, P., Johnson, L. A. M., Shemar, S. L., Whibberley, P. B., Calonico, D., Levi, F., Lorini, L., Pizzocaro, M., et al. (2013) · 2013 Joint European Frequency and Time Forum & International Frequency Control Symposium (EFTF/IFC) · doi:10.1109/eftf-ifc.2013.6702183 · Cited by 15
Self-citationMargolis, H. S., & Gill, P. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012060 · Cited by 5
Self-citation
Research works printed but not linked: 1
- (16) Dub´ e, P.; Bernard, J. E.; Gertsvolf, M.; Metrologia 2017 , 54 , 290. -
Cited by
Improved Limits for Violations of Local Position Invariance from Atomic Clock Comparisons
Lange, R., Huntemann, N., Rahm, J. M., Sanner, C., Shao, H., Lipphardt, B., Tamm, C., Weyers, S., & Peik, E. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.011102 · Cited by 200
Intercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64
Pizzocaro, M., Bregolin, F., Barbieri, P., Rauf, B., Levi, F., & Calonico, D. (2020) · Metrologia · doi:10.1088/1681-7575/ab50e8 · Cited by 63
Analysis of atomic-clock data to constrain variations of fundamental constants
Sherrill, N., Parsons, A. O., Baynham, C. F. A., Bowden, W., Curtis, E. A., Hendricks, R., Hill, I. R., Hobson, R., Margolis, H. S., Robertson, B., et al. (2023) · New Journal of Physics · doi:10.1088/1367-2630/aceff6 · Cited by 98
Self-citationGeopotential measurement with a robust, transportable Ca+ optical clock
Huang, Y., Zhang, H., Zhang, B., Hao, Y., Guan, H., Zeng, M., Chen, Q., Lin, Y., Wang, Y., Cao, S., et al. (2020) · Physical Review A · doi:10.1103/physreva.102.050802 · Cited by 52
Metadata
- Authors
- Baynham, C. F. A., Godun, R. M., Jones, J. M., King, S. A., Nisbet-Jones, P. B. R., Baynes, F., Rolland, A., Baird, P. E. G., Bongs, K., Gill, P., & Margolis, H. S.
- Affiliations
- National Physical Laboratory (GB)
- University of Oxford (GB)
- University of Birmingham (GB)
- Corresponding author
- Godun, Rachel M.
- Venue
- Journal of Modern Optics
- Publisher
- Informa UK Limited
- Published
- 2017-10-06
- Volume
- 65
- Issue
- 5-6
- Pages
- 585-591
- ISSN
- 0950-0340 (ISSN-L)
- 1362-3044
- OpenAlex
- W2728318801
- Cited by
- 32
- References
- 31
- Citations by year
- 2025: 4 · 2024: 4 · 2023: 6 · 2022: 2 · 2021: 4 · 2020: 7 · 2019: 2 · 2018: 3
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Update notices
- correction (2018-01-24)
- Open access
- green
- arxiv.org
- Locations
- Journal of Modern Optics (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- arXiv (Cornell University)
- Funders
- European Metrology Research Programme (SIB55-ITOC)
- Department for Business, Energy and Industrial Strategy (National Measurement System Programme)
- UK Department for Business, Energy and Industrial Strategy
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- 171Yb, optical clock transition, electric octupole transition, absolute frequency measurement, frequency standards, Yb3+, traceability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.