Fireside and steamside performance in biomass power plant
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
To address the challenge of climate change, the energy sector is developing novel strategies to reduce greenhouse gas emissions. One route is to increase steam temperatures and pressures (above 650°C and 350 bar). Another route is the use of potential net zero emissions fuels, like biomass. Both these routes cause issues for the heat-exchanger materials due to the differences in composition of the combustion environments generated, compared to coal.This paper characterises candidate superheater/reheater alloys’ behaviour (Sanicro 25 and IN740) at 700°C. 1,000 h fireside and 10,000 h steamside exposures were carried out, the first using ‘deposit recoat’ techniques. Sample cross-sections were analysed using dimensional metrology and SEM/EDX. Fireside results for Sanicro 25 showed degradation throughout the samples’ thicknesses. In steamside exposures, Sanicro 25 formed a Cr-rich scale, and Nb rich particles (z-phase). IN740 showed lower metal and sound metal damage than Sanicro 25 for fireside and steam oxidation exposures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“It is anticipated from literature [15,17,20,21], that a mixed deposit chemistry will decrease the melting point of the resulting mixture.This in turn is likely to shift the bell-shaped curve for fireside corrosion damage; moving it towards lower temperatures [15,17,20,21].”
From Fireside corrosion and deposition on heat exchangers in biomass combustion systems (2023) · cites this paper as [15]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This is due to the ability of Cl to react via an ion exchange mechanism [15] that enhances corrosion damage.”
From Fireside corrosion and deposition on heat exchangers in biomass combustion systems (2023) · cites this paper as [15]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The availability of chlorides would be influenced by the S/Cl ratio, which determine the eutectic melt fraction of the deposit [15].”
From Fireside corrosion and deposition on heat exchangers in biomass combustion systems (2023) · cites this paper as [15]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“In deposit D1 there is a simultaneous presence of Na and K, which could result in a lower melting temperature, respect to the K system only (as low as 310°C with 30% NaCl) [15,17,38].”
From Fireside corrosion and deposition on heat exchangers in biomass combustion systems (2023) · cites this paper as [15]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“It can be observed that there is overlap in the Na, K and S maps (Figure 7 and Figure 11), which could suggest the formation of K 3 Na(SO 4 ) 2 with low melting point [15].”
From Fireside corrosion and deposition on heat exchangers in biomass combustion systems (2023) · cites this paper as [15]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Co-firing of coal and biomass fuel blends
Sami, M., Annamalai, K., & Wooldridge, M. (2001) · Progress in Energy and Combustion Science · doi:10.1016/s0360-1285(00)00020-4 · Cited by 838
Ash Deposition in Biomass Combustion or Co-Firing for Power/Heat Generation
Shao, Y., Wang, J., Preto, F., Zhu, J., & Xu, C. (2012) · Energies · doi:10.3390/en5125171 · Cited by 178
Fireside corrosion of superheaters: Effects of air and oxy-firing of coal and biomass
Syed, A. U., Simms, N. J., & Oakey, J. E. (2011) · Fuel · doi:10.1016/j.fuel.2011.03.010 · Cited by 118 · cited 1×
“Rig layout for fireside corrosion tests [20].”
Self-citationChai, G., Boström, M., Olaison, M., & Forsberg, U. (2013) · Procedia Engineering · doi:10.1016/j.proeng.2013.03.248 · Cited by 80
Trends in fireside corrosion damage to superheaters in air and oxy-firing of coal/biomass
Hussain, T., Syed, A. U., & Simms, N. J. (2013) · Fuel · doi:10.1016/j.fuel.2013.04.005 · Cited by 64 · cited 1×
“The result of this behaviour, together with differences in the local metal temperatures in the heat exchanger network, implies that some regions of the heat exchangers will have metal temperatures that are hotter than the damage peak temperature, leading to relatively lower damage rates, while other regions will have…”
BackgroundSelf-citationCurrent limitations of high-temperature alloys in practical applications
Stringer, J., & Wright, I. G. (1995) · Oxidation of Metals · doi:10.1007/bf01046730 · Cited by 59 · cited 1×
“methods for analysing corrosion data is becoming more widespread and provides a good basis for corrosion model development and validation [33,34].”
MethodZurek, J., Yang, S. ‐., Lin, D., Hüttel, T., Singheiser, L., & Quadakkers, W. J. (2014) · Materials and Corrosion · doi:10.1002/maco.201407901 · Cited by 56
Predicting long-term creep-rupture property of Inconel 740 and 740H
Dang, Y. Y., Zhao, X., Yuan, Y., Ying, H., Lu, J. T., Yang, Z. Z., & Gu, Y. (2015) · Materials at High Temperatures · doi:10.1179/1878641315y.0000000010 · Cited by 47
Degradation of heat exchanger materials under biomass co-firing conditions
Simms, N. J., Kilgallon, P. J., & Oakey, J. E. (2007) · Materials at High Temperatures · doi:10.1179/096034007x281640 · Cited by 46
Self-citationLukaszewicz, M., Simms, N. J., Dudziak, T. P., & Nicholls, J. R. (2013) · Oxidation of Metals · doi:10.1007/s11085-013-9358-2 · Cited by 41
Self-citationOxidation Behaviour of Sanicro 25 (42Fe22Cr25NiWCuNbN) in O2/H2O Mixture at 600 °C
Intiso, L., Johansson, L. G., Canovic, S., Bellini, S., Svensson, J., & Halvarsson, M. (2012) · Oxidation of Metals · doi:10.1007/s11085-011-9281-3 · Cited by 40
High Pressure Steam Oxidation of Alloys for Advanced Ultra-Supercritical Conditions
Holcomb, G. R. (2014) · Oxidation of Metals · doi:10.1007/s11085-014-9491-6 · Cited by 38
A microstructural investigation into the accelerated corrosion of P91 steel during biomass co-firing
O’Hagan, C. P., O’Brien, B., Leen, S. B., & Monaghan, R. F. D. (2016) · Corrosion Science · doi:10.1016/j.corsci.2016.03.028 · Cited by 38
Field test corrosion experiments in Denmark with biomass fuels. Part 2: Co-firing of straw and coal
Montgomery, M., & Larsen, O. H. (2002) · Materials and Corrosion · doi:10.1002/1521-4176(200203)53:3<185::aid-maco185>3.0.co;2-k · Cited by 36
Khodier, A., Hussain, T., Simms, N. J., Oakey, J. E., & Kilgallon, P. J. (2011) · Fuel · doi:10.1016/j.fuel.2011.09.029 · Cited by 34
Self-citationThe impact of uncertainties on the UK's medium-term climate change targets
Watson, J., Gross, R., Ketsopoulou, I., & Winskel, M. (2015) · Energy Policy · doi:10.1016/j.enpol.2015.02.030 · Cited by 33
Lu, J., Yang, Z., Li, Y., Huang, J., Zhou, Y., Zhao, X., & Yuan, Y. (2018) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-017-3051-6 · Cited by 23
Creep and Fatigue Interaction Behavior in Sanicro 25 Heat Resistant Austenitic Stainless Steel
Calmunger, M., Chai, G., Johansson, S., & Moverare, J. J. (2016) · Transactions of the Indian Institute of Metals · doi:10.1007/s12666-015-0806-3 · Cited by 20
High temperature creep of Sanicro 25 austenitic steel at low stresses
Kloc, L., Dymáček, P., & Sklenička, V. (2018) · Materials Science and Engineering A · doi:10.1016/j.msea.2018.02.095 · Cited by 18
Rutkowski, B., Gil, A., Agüero, A., González, V., & Czyrska-Filemonowicz, A. (2018) · Oxidation of Metals · doi:10.1007/s11085-017-9824-3 · Cited by 17
A Code of Practice for Discontinuous Corrosion Testing in High Temperature Gaseous Atmospheres
Meadowcroft, D. B., Tomkings, A. B., Grabke, H. J., Hertzman, S., Johansson, R., Jönsson, B., Lindén, J., Klöwer, J., Nicholls, J. R., Norton, J. F., et al. (1997) · Materials science forum · doi:10.4028/www.scientific.net/msf.251-254.973 · Cited by 11
Hussain, T., Khodier, A., & Simms, N. J. (2013) · Fuel · doi:10.1016/j.fuel.2013.01.001 · Cited by 11
Self-citationFireside Corrosion of Heat Exchanger Materials for Advanced Solid Fuel Fired Power Plants
Mori, S., Pidcock, A., Sumner, J., Simms, N., & Oakey, J. (2022) · Oxidation of Metals · doi:10.1007/s11085-021-10094-z · Cited by 11 · cited 4×
“change found in a previous study looking at the accelerated fireside corrosion of this material under co-firing conditions (median damage around 300 μm [35],).”
BackgroundResultSelf-citation
Research works printed but not linked: 9
- European Climate Foundation, Roadmap 2050:A practical guide to a prosperous, low-carbon Europe. Brussels: European Climate Foundation; 2010.
- European Commission, State of play on the sustainability of solid and gaseous biomass used for electricity, heating and cooling in the EU. Brussels: European Commission; 2014. doi:https://doi.org/10.1017/CBO9781107415324.004(open in a new window). · doi:10.1017/cbo9781107415324.004(open
- European Commission, A policy framework for climate and energy in the period from 2020 to 2030. Brussels: European Commission; 2014.
- Froggatt A, Hadfield A. Deconstructing the European Energy Union: governance and 2030 Goals. London: UK Energy Research Centre; 2015.
- Camara G, Toland, J, Hudson, T et al, . LIFE and Climate change mitigation. Luxembourg: Publications Office of the European Union; 2015 978-92-79-43945-2 .
- Nicol K. Status of advanced ultra-supercritical pulverised coal technology. London UK: IEA Clean Coal Center; 2013.
- Rutkowski B, Gil A, Agüero A, et al. Microstructure, chemical- and phase composition of Sanicro 25 austenitic steel after oxidation in steam at 700 °C. Oxid Met. 2018;89(7):609–621.
- Simms NJ, Kilgallon, PJ, Oakey, John, et al. Fireside issues in advanced power generation systems. Mater Sci Technol. 2012.
- Grabke HJ. Guidelines for methods of testing and research in high temperature corrosion EFC 14. London: European Federation of Corrosion Publications; 1995.
Cited by
Fireside corrosion and deposition on heat exchangers in biomass combustion systems
Mori, S., Sanusi, T., Simms, N., & Sumner, J. (2023) · Materials at High Temperatures · doi:10.1080/09603409.2022.2138007 · Cited by 8
“This is in agreement with literature findings and could be formed through the reaction [15]:”
BackgroundResultSelf-citationJoy, T., Mori, S., & Sumner, J. (2025) · Journal of Energy Storage · doi:10.1016/j.est.2025.115554 · Cited by 4
Self-citationUsman, A., Isern, L., Nicholls, J. R., Cordero-Cabrera, M. C., & Syed, A. U. (2025) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-025-11630-7 · Cited by 3
“12, 13, 14, 15) and Co-oxide (Fig.”
Fireside performance of different coatings in biomass power plant
Mori, S., Pidcock, A., Sumner, J., Simms, N. J., & Oakey, J. E. (2023) · Materials at High Temperatures · doi:10.1080/09603409.2023.2188351 · Cited by 2
“One is to use more expensive Ni-based alloy [29].”
BackgroundMethodSelf-citationYULIANSYAH, Y., HAQIQI, M. T., Setiawan, K. A., Setiawan, A., SAPUTRA, P. D., ROMADLON, H. S. I., MUKHDLOR, A., Ramadhan, R., & Amirta, R. (2022) · Biodiversitas Journal of Biological Diversity · doi:10.13057/biodiv/d230709 · Cited by 2
“It will potentially lead to a zero-emission power system (Mori et al. 2022).”
Background
Metadata
- Authors
- Mori, S., Sumner, J., Bouvet, J., & Simms, N. J.
- Affiliations
- Cranfield University (GB)
- Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR)
- Corresponding author
- Mori, Stefano
- Venue
- Materials at High Temperatures
- Publisher
- Informa UK Limited
- Published
- 2022-01-10
- Volume
- 39
- Issue
- 2
- Pages
- 106-121
- ISSN
- 0960-3409 (ISSN-L)
- 1878-6413
- OpenAlex
- W4206053861
- Cited by
- 5
- References
- 23
- Citations by year
- 2025: 2 · 2023: 1 · 2022: 2
- FWCI
- 0.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Materials at High Temperatures (publishedVersion, cc-by)
- CERES (Cranfield University) (submittedVersion, cc-by)
- Funders
- Engineering and Physical Sciences Research Council (EP/K021095/1)
- Research Fund for Coal and Steel (RFCS-2015/709954)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › High Temperature Alloys and Creep
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › High-Temperature Coating Behaviors
- Physical Sciences › Materials Science › Materials Chemistry › Nuclear Materials and Properties
- Keywords
- biomass combustion, Sanicro 25, high-temperature oxidation, Z-phase, heat exchanger materials, biomass power plants, high-temperature corrosion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.