Clinical Applications of Electrical Stimulation After Spinal Cord Injury
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
During the last one-half century, electrical stimulation has become clinically significant for improving health and restoring useful function after spinal cord injury. Short-term stimulation can be provided by electrodes on the skin or percutaneous fine wires, but implanted systems are preferable for long-term use. Electrical stimulation of intact lower motor neurons can exercise paralyzed muscles and reverse wasting; improve strength, endurance, and cardiovascular fitness; and may reduce the progression of osteoporosis. Other potential therapeutic uses being investigated include reduction of spasticity, prevention of deep vein thrombosis, and improvement of tissue health. Pacing of intact phrenic nerves in high tetraplegia can produce effective respiration without mechanical ventilation, allowing improved speech, increased mobility, and increased sense of well-being. Improvement of cough has also been demonstrated. Stimulation of intact sacral nerves can produce effective micturition and reduce urinary tract infection; it can also improve bowel function and erection. It is usually combined with posterior sacral rhizotomy to improve continence and bladder capacity, and the combination has been shown to reduce costs of care. Electroejaculation can now produce semen in most men with spinal cord injury. Significant achievements have also been made in restoring limb function. Useful hand grasp can be provided in C5 and C6 tetraplegia, reducing dependence on adapted equipment and assistants. Standing, assistance with transfers, and walking for short distances can be provided to selected persons with paraplegia, improving their access to objects, places, and opportunities that are inaccessible from a wheelchair. This review summarizes the current state of therapeutic and neuroprosthetic applications of electrical stimulation after spinal cord injury and identifies some future directions of research and clinical and commercial development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The first 500 patients with sacral anterior root stimulator implants: general description
Brindley, G. S. (1994) · Spinal Cord · doi:10.1038/sc.1994.126 · Cited by 318
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192
Self-citationKobetic, R., Sharma, M., Triolo, R. J., Uhlir, J. P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E. B., Davis, J. A., & Ferguson, K. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808942 · Cited by 155
Self-citationInter-rater Reliability of a Clinical Test of Standing Function
Triolo, R. J., Bevelheimer, T., Eisenhower, G., & Wormser, D. (1995) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.1995.11719375 · Cited by 23
Self-citation
Cited by
Ragnarsson, K. T. (2008) · Spinal Cord · doi:10.1038/sj.sc.3102091 · Cited by 301
Interfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98
“…in humans with good success for functional electrical stimulation of the upper and lower extremities, as well as control of micturition, respiration, and other functions (Creasey et al., 1996; Creasey et al., 2004; Liberson, Holmquest, Scot, & Dow, 1961; Peckham, Marsolais, & Mortimer, 1980).”
BackgroundFisher, L. E., Tyler, D. J., Anderson, J. S., & Triolo, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046010 · Cited by 89
Self-citationSchiefer, M. A., Freeberg, M., Pinault, G. J. C., Anderson, J., Hoyen, H., Tyler, D. J., & Triolo, R. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056006 · Cited by 57
Self-citationLi, L.-J., Zhang, J., Zhang, F., Lineaweaver, W. C., Chen, T.-Y., & Chen, Z.-W. (2005) · Microsurgery · doi:10.1002/micr.20159 · Cited by 14
Metadata
- Authors
- Creasey, G. H., Ho, C. H., Triolo, R. J., Gater, D. R., DiMarco, A. F., Bogie, K. M., & Keith, M. W.
- Venue
- The Journal of Spinal Cord Medicine
- Publisher
- Informa UK Limited
- Published
- 2004-01
- Volume
- 27
- Issue
- 4
- Pages
- 365-375
- ISSN
- 1079-0268 (ISSN-L)
- 2045-7723
- OpenAlex
- W139097051
- Cited by
- 102
- References
- 5
- Type
- book review
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Applications of Electrical Stimulation After Spinal Cord Injury. https://app.cochat.ai/papers/10.1080/10790268.2004.11753774
- The paper
- Creasey, G. H., Ho, C. H., Triolo, R. J., Gater, D. R., DiMarco, A. F., Bogie, K. M., & Keith, M. W. (2004). Clinical Applications of Electrical Stimulation After Spinal Cord Injury. The Journal of Spinal Cord Medicine. https://doi.org/10.1080/10790268.2004.11753774
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.