Balancing yield, purity and practicality: a modified differential ultracentrifugation protocol for efficient isolation of small extracellular vesicles from human serum
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Ultracentrifugation remains the gold standard for isolation of small extracellular vesicles (sEV), particularly for cancer applications. The objective of this study was to determine if a widely used ultracentrifugation protocol for isolation of serum sEV could be modified to reduce the number of ultracentrifugation cycles and increase efficiency, while maintaining equal or better sample purity and yield. Serum was obtained from two healthy subjects. sEVs were isolated from 1 mL aliquots using three different ultracentrifugation protocols. Co-isolation of RNA carrier protein was assessed by performing Western blots for ApoA-I, ApoB, and Ago2. Small RNA-sequencing was performed on the sEV isolates, and differential detection of small ncRNA was compared across isolation protocols. Reduction from three- to two-ultracentrifuge cycles with no sucrose cushion resulted in a much higher sEV yield but also had the highest levels of lipoprotein and Ago2 contamination. However, the two-ultracentrifugation cycle protocol that incorporated a 30% sucrose cushion into the first cycle resulted in slightly higher sEV yields with lower levels of protein contamination compared to the lengthier three-ultracentrifugation cycle approach, therefore presenting a more efficient alternative approach for isolation of serum sEVs. It was also notable that there were some differences in sEV ncRNA cargo according to protocol, although it was less than expected given the differences in co-isolated RNA carrier proteins. Our results suggest that use of the modified serum sEV isolation protocol with two ultracentrifugation cycles and incorporating a 30% sucrose cushion offers a more efficient approach in terms of efficiency and purity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moderated estimation of fold change and dispersion for RNA-seq data with DESeq2
Love, M. I., Huber, W., & Anders, S. (2014) · Genome Biology · doi:10.1186/s13059-014-0550-8 · Cited by 95,106
McCarthy, D. J., Chen, Y., & Smyth, G. K. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks042 · Cited by 5,195
GENCODE: The reference human genome annotation for The ENCODE Project
Harrow, J., Frankish, A., Gonzalez, J. M., Tapanari, E., Diekhans, M., Kokocinski, F., Aken, B. L., Barrell, D., Zadissa, A., Searle, S., et al. (2012) · Genome Research · doi:10.1101/gr.135350.111 · Cited by 4,585 · cited 2×
“Small non-coding RNA (ncRNA) – miRNA, misc_RNA, scRNA, snRNA, sRNA, snoRNA, scaRNA – were quantified based on the M16 release of GENCODE [42,43] via RNA-Seq by Expectation Maximization (RSEM) using the RSEM package [44].”
MethodCharacterization of extracellular circulating microRNA
Turchinovich, A., Weiz, L., Langheinz, A., & Burwinkel, B. (2011) · Nucleic Acids Research · doi:10.1093/nar/gkr254 · Cited by 1,941
Filipe, V., Hawe, A., & Jiskoot, W. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0073-2 · Cited by 1,885 · cited 1×
“One minor limitation of this study is that NTA, which was used to quantify the sEV yield for each protocol, cannot discriminate between extracellular vesicles and protein aggregates or other nanoparticles within the same size range [40].”
MethodRNA-SeQC: RNA-seq metrics for quality control and process optimization
DeLuca, D. S., Levin, J. Z., Sivachenko, A., Fennell, T., Nazaire, M.-D., Williams, C., Reich, M., Winckler, W., & Getz, G. (2012) · Bioinformatics · doi:10.1093/bioinformatics/bts196 · Cited by 899
Cited by
Yang, D., Zhang, W., Zhang, H., Zhang, F., Chen, L., Ma, L., Larcher, L. M., Chen, S., Liu, N., Zhao, Q., et al. (2020) · Theranostics · doi:10.7150/thno.41580 · Cited by 1,023
Jia, Y., Yu, L., Ma, T., Xu, W., Qian, H., Sun, Y., & Shi, H. (2022) · Theranostics · doi:10.7150/thno.74305 · Cited by 391
Advances in mesenchymal stem cell exosomes: a review
Tang, Y., Zhou, Y., & Li, H.-J. (2021) · Stem Cell Research & Therapy · doi:10.1186/s13287-021-02138-7 · Cited by 327
“weight balance of exosomes during pregnancy affects term and preterm birth and reflects physiological changes in the ectoderm and can therefore be used as a biomarker and indicator of cell function [24].”
BackgroundMesenchymal Stem Cell-Derived Extracellular Vesicles to the Rescue of Renal Injury
Birtwistle, L., Chen, X.-M., & Pollock, C. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22126596 · Cited by 113
“Disadvantages - Time-consuming [63] - Labour-intensive - Instrument-dependent: rotor type and centrifugal force [61,67] - Inappropriate for small sample volume [63] - Contaminating pellet of lipoproteins, nucleic acids [45,68] - Time-consuming (density preparation) [63] - Instrumentdependent [63] - Must combine with S…”
BackgroundYang, L., Patel, K. D., Rathnam, C., Thangam, R., Hou, Y., Kang, H., & Lee, K. (2022) · Small · doi:10.1002/smll.202104783 · Cited by 81
Metadata
- Authors
- Langevin, S. M., Kuhnell, D., Orr-Asman, M. A., Biesiada, J., Zhang, X., Medvedovic, M., & Thomas, H. E.
- Venue
- RNA Biology
- Publisher
- Informa UK Limited
- Published
- 2019-01-02
- Volume
- 16
- Issue
- 1
- Pages
- 5-12
- ISSN
- 1547-6286 (ISSN-L)
- 1555-8584
- OpenAlex
- W2906829165
- Cited by
- 92
- References
- 6
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Balancing yield, purity and practicality: a modified differential ultracentrifugation protocol for efficient isolation of small extracellular vesicles from human serum. https://app.cochat.ai/papers/10.1080/15476286.2018.1564465
- The paper
- Langevin, S. M., Kuhnell, D., Orr-Asman, M. A., Biesiada, J., Zhang, X., Medvedovic, M., & Thomas, H. E. (2019). Balancing yield, purity and practicality: a modified differential ultracentrifugation protocol for efficient isolation of small extracellular vesicles from human serum. RNA Biology. https://doi.org/10.1080/15476286.2018.1564465
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.