A high-ITR SSVEP-based BCI speller
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Spelling is an important application of brain-computer interfaces (BCIs). Previous BCI spellers were not suited for widespread use due to their low information transfer rate (ITR). In this study, we constructed a high-ITR BCI speller based on the steady-state visual evoked potential (SSVEP). A 45-target BCI speller was implemented with a frequency resolution of 0.2 Hz. A sampled sinusoidal stimulation method was used to present visual stimuli on a conventional LCD screen. The online results revealed that the proposed BCI speller had a good performance, reaching a high average accuracy (84.1% for 2 s stimulation time; 90.2% for 3 s stimulation time) and the corresponding high ITR (105 bits/min for 2 s stimulation time, 82 bits/min for 3 s stimulation time) during the low-frequency stimuli, while 88.7% and 61 bits/min were achieved for a 4 s time window during the high-frequency stimuli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Mu rhythm (de)synchronization and EEG single-trial classification of different motor imagery tasks
Pfurtscheller, G., Brunner, C., Schlögl, A., & Lopes da Silva, F. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.003 · Cited by 1,587
Human Brain Electrophysiology: Evoked Potentials and Evoked Magnetic Fields in Science and Medicine
Regan, D. M. (1989) · Medical Entomology and Zoology · Cited by 1,300
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
Herrmann, C. S. (2001) · Experimental Brain Research · doi:10.1007/s002210100682 · Cited by 1,080 · cited 2×
“[41,44] Additionally, the amplitude of the SSVEP significantly decreases in the high-frequency range; the higher the SSVEP amplitude, the more easily it is detected.”
BackgroundSteady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
Frequency recognition based on canonical correlation analysis for SSVEP-based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889197 · Cited by 867
Self-citationDesign and implementation of a brain-computer interface with high transfer rates
Cheng, M., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 818
Self-citationBin, G., Gao, X., Yan, Z., Hong, B., & Gao, S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046002 · Cited by 773
Self-citationFrequency Recognition Based on Canonical Correlation Analysis for SSVEP-Based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886577 · Cited by 724
Self-citationA Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654
A BCI-based environmental controller for the motion-disabled
Gao, X., Xu, D., Cheng, M., & Gao, S. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814449 · Cited by 637
Self-citationLeeb, R., Friedman, D., Müller-Putz, G. R., Scherer, R., Slater, M., & Pfurtscheller, G. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/79642 · Cited by 479
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
Self-citationBrain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423 · cited 1×
“[21,22] When users focus their attention on one of the targets, an SSVEP occurs in the visual cortex at the flickering frequency and its harmonics.”
BackgroundSelf-citationEEG-based communication: improved accuracy by response verification
Wolpaw, J. R., Ramoser, H., McFarland, D. J., & Pfurtscheller, G. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.712231 · Cited by 396
Human Brain Electrophysiology. Evoked Potentials and Evoked Magnetic Fields in Science and Medicine
Picton, T. (1990) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199007000-00010 · Cited by 372
BCI demographics: how many (and what kinds of) people can use an SSVEP BCI?
Allison, B., Luth, T., Valbuena, D., Teymourian, A., Volosyak, I., & Graser, A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039495 · Cited by 344 · cited 1×
“[14–17] The majority of the existing SSVEP-based BCI systems are gaze-dependent because of the high signal-to-noise ratio (SNR) in EEG recordings and the high information transfer rate (ITR) desired in BCI performance.”
BackgroundAn Asynchronously Controlled EEG-Based Virtual Keyboard: Improvement of the Spelling Rate
Scherer, R., Muller, G. R., Neuper, C., Graimann, B., & Pfurtscheller, G. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827062 · Cited by 340
Conversion of EEG activity into cursor movement by a brain-computer interface (BCI)
Fabiani, G. E., McFarland, D. J., Wolpaw, J. R., & Pfurtscheller, G. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.834627 · Cited by 292
Does the ‘P300’ speller depend on eye gaze?
Brunner, P., Joshi, S., Briskin, S., Wolpaw, J. R., Bischof, H., & Schalk, G. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056013 · Cited by 291
A Self-Paced and Calibration-Less SSVEP-Based Brain–Computer Interface Speller
Cecotti, H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039594 · Cited by 253
Development of an SSVEP-based BCI spelling system adopting a QWERTY-style LED keyboard
Hwang, H.-J., Lim, J.-H., Jung, Y.-J., Choi, H., Lee, S. W., & Im, C.-H. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.04.011 · Cited by 251
SSVEP-based Bremen–BCI interface—boosting information transfer rates
Volosyak, I. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036020 · Cited by 232
Asynchronous BCI control using high-frequency SSVEP
Diez, P. F., Mut, V. A., Avila Perona, E. M., & Laciar Leber, E. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-39 · Cited by 212
Motor imagery and EEG-based control of spelling devices and neuroprostheses
Neuper, C., Müller-Putz, G. R., Scherer, R., & Pfurtscheller, G. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(06)59025-9 · Cited by 208
Frequency and Phase Mixed Coding in SSVEP-Based Brain--Computer Interface
Jia, C., Gao, X., Hong, B., & Gao, S. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2068571 · Cited by 197
Self-citationStimulator selection in SSVEP-based BCI
Wu, Z., Lai, Y., Xia, Y., Wu, D., & Yao, D. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.01.004 · Cited by 192
N200-speller using motion-onset visual response
Hong, B., Guo, F., Liu, T., Gao, X., & Gao, S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.06.026 · Cited by 192
Self-citationVisual stimulus design for high-rate SSVEP BCI
Wang, Y., Wang, Y.-T., & Jung, T.-P. (2010) · Electronics Letters · doi:10.1049/el.2010.0923 · Cited by 183
Díez, P., Müller, S. M. T., Mut, V. A., Laciar, E., Avila, E., Bastos-Filho, T., & Sarcinelli-Filho, M. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.12.005 · Cited by 180
Spüler, M., Rosenstiel, W., & Bogdan, M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0051077 · Cited by 177
BCI Demographics II: How Many (and What Kinds of) People Can Use a High-Frequency SSVEP BCI?
Volosyak, I., Valbuena, D., Luth, T., Malechka, T., & Graser, A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2121919 · Cited by 175
Yuan, P., Gao, X., Allison, B., Wang, Y., Bin, G., & Gao, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026014 · Cited by 160
Self-citationHillyard, S. A., Hinrichs, H., Tempelmann, C., Morgan, S. T., Hansen, J. C., Scheich, H., & Heinze, H.-J. (1997) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1997)5:4<287::aid-hbm14>3.0.co;2-b · Cited by 129
The Berlin Brain-Computer Interface presents the novel mental typewriter Hex-o-Spell
Blankertz, B., Dornhege, G., Krauledat, M., Schröder, M., Williamson, J., Murray‐Smith, R., & Müller, K. (2006) · Maynooth University ePrints and eTheses Archive (Maynooth University) · Cited by 127
Manyakov, N. V., Chumerin, N., Robben, A., Combaz, A., van Vliet, M., & Hulle, M. M. V. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036011 · Cited by 126
Event-related dynamics of brain oscillations
Neuper, C., & Klimesch, W. (2006) · Cited by 115
Is It Significant? Guidelines for Reporting BCI Performance
Billinger, M., Daly, I. P., Kaiser, V., Jin, J., Allison, B. Z., Müller-Putz, G., & Brunner, C. (2012) · Biological and medical physics series · doi:10.1007/978-3-642-29746-5_17 · Cited by 115
Brain-computer interface based on the high-frequency steady-state visual evoked potential
Yijun, W., Ruiping, W., Xiaorong, G., & Shangkai, G. (2005) · Proceedings. 2005 First International Conference on Neural Interface and Control, 2005. · doi:10.1109/icnic.2005.1499837 · Cited by 96
Wu, C.-H., Chang, H., Lee, P., Li, K.-S., Sie, J.-J., Sun, C., Yang, C., Li, P.-H., Deng, H.-T., & Shyu, K. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.12.014 · Cited by 87
Coherent Photoacoustic-Ultrasound Correlation and Imaging
Gao, F., Feng, X., & Zheng, Y. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2321007 · Cited by 67
Brain–computer interface based on intermodulation frequency
Chen, X., Chen, Z., Gao, S., & Gao, X. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066009 · Cited by 62
Self-citationA visual parallel-BCI speller based on the time–frequency coding strategy
Xu, M., Chen, L., Zhang, L., Qi, H., Ma, L., Tang, J., Wan, B., & Ming, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026014 · Cited by 47
Zheng, Y. L., Gao, X., & Gao, S. (2011) · Science China Information Sciences · doi:10.1007/s11432-011-4503-5 · Cited by 27
Self-citationDetection of high frequency steady state visual evoked potentials for Brain-computer interfaces
Garcia‐Molina, G., Ibañez, D. P., Mihajlović, V., & Chestakov, D. A. (2009) · Cited by 21
Hoffmann, U., Fimbel, E. J., & Keller, T. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109334 · Cited by 16
Cited by
High-speed spelling with a noninvasive brain–computer interface
Chen, X., Wang, Y., Nakanishi, M., Gao, X., Jung, T.-P., & Gao, S. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1508080112 · Cited by 969
“sinð2πNh ftÞ cosð2πNh ftÞ 3 (7)7775 , [6]”
Self-citationEnhancing Detection of SSVEPs for a High-Speed Brain Speller Using Task-Related Component Analysis
Nakanishi, M., Wang, Y., Chen, X., Wang, Y.-T., Gao, X., & Jung, T.-P. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2694818 · Cited by 813
Self-citationChen, X., Wang, Y., Gao, S., Jung, T.-P., & Gao, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046008 · Cited by 805
Self-citationA Benchmark Dataset for SSVEP-Based Brain–Computer Interfaces
Wang, Y., Chen, X., Gao, X., & Gao, S. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2627556 · Cited by 501
Self-citationNakanishi, M., Wang, Y., Wang, Y.-T., & Jung, T.-P. (2015) · PLoS ONE · doi:10.1371/journal.pone.0140703 · Cited by 376
“Because it is highly efficient, easy to implement, and does not require calibration, the standard CCA method has been widely used in online BCIs in recent years [9, 10, 24, 25].”
Method
Metadata
- Authors
- Chen, X., Chen, Z., Gao, S., & Gao, X.
- Venue
- Brain-Computer Interfaces
- Publisher
- Informa UK Limited
- Published
- 2014-09-15
- Volume
- 1
- Issue
- 3-4
- Pages
- 181-191
- ISSN
- 2326-2621 (ISSN-L)
- 2326-263X
- OpenAlex
- W1968916327
- Cited by
- 301
- References
- 50
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.