The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
The permeability of the endplate channel to organic cations in frog muscle.
Open accessAbstract
The relative permeability of endplate channels to many organic cations was determined by reversal-potential criteria. Endplate currents induced by iontophoretic "puffs" of acetylcholine were studied by a Vaseline gap, voltage clamp method in cut muscle fibers. Reversal potential changes were measured as the NaCl of the bathing medium was replaced by salts of organic cations, and permeability ratios relative to Na+ ions were calculated from the Goldman-Hodgkin-Katz equation. 40 small monovalent organic cations had permeability ratios larger than 0.1. The most permeant including NH4+, hydroxylamine, hydrazine, methylamine, guanidine, and several relatives of guanidine had permeability ratios in the range 1.3--2.0. However, even cations such as imidazole, choline, tris(hydroxymethyl)aminomethane, triethylamine, and glycine methylester were appreciably permeant with permeability ratios of 0.13--0.95. Four compounds with two charged nitrogen groups were also permeant. Molecular models of the permeant ions suggest that the smallest cross-section of the open pore must be at least as large as a square, 6.5 A x 6.5 A. Specific chemical factors seem to be less important than access or friction in determining the ionic selectivity of the endplate channel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effect of sodium ions on the electrical activity of the giant axon of the squid
Hodgkin, A. L., & Katz, B. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004310 · Cited by 3,520
Potential, impedance, and rectification in membranes
Goldman, D. E. (1943) · Journal of General Physiology · doi:10.1085/jgp.27.1.37 · Cited by 2,777
An analysis of the end‐plate potential recorded with an intra‐cellular electrode
Fatt, P., & Katz, B. (1951) · The Journal of Physiology · doi:10.1113/jphysiol.1951.sp004675 · Cited by 1,400
Filtration, diffusion, and molecular sieving through porous cellulose membranes.
Renkin, E. M. (1954) · PubMed Central · Cited by 1,084
CONDUCTANCE FLUCTUATIONS AND IONIC PORES IN MEMBRANES
Neher, E., & Stevens, C. F. (1977) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.06.060177.002021 · Cited by 508
On the permeability of end‐plate membrane during the action of transmitter
Takeuchi, A., & Takeuchi, N. (1960) · The Journal of Physiology · doi:10.1113/jphysiol.1960.sp006564 · Cited by 429
Lewis, C. A. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012629 · Cited by 394
The permeability of endplate channels to monovalent and divalent metal cations.
Adams, D. J., Dwyer, T. M., & Hille, B. (1980) · The Journal of general physiology · doi:10.1085/jgp.75.5.493 · Cited by 331
Self-citationAn improved vaseline gap voltage clamp for skeletal muscle fibers.
Hille, B., & Campbell, D. T. (1976) · The Journal of general physiology · doi:10.1085/jgp.67.3.265 · Cited by 311
Self-citationIonic selectivity of Na and K channels of nerve membranes.
Hille, B. (1975) · PubMed · Cited by 269
Self-citation
Cited by
Glutamate receptor ion channels
Mayer, M. L. (2005) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2005.05.004 · Cited by 3,640
The Glutamate Receptor Ion Channels
Dingledine, R., Borges, K., Bowie, D., & Traynelis, S. F. (1999) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01394-2 · Cited by 3,554
Bormann, J., Hamill, O. P., & Sakmann, B. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016493 · Cited by 1,157
Glutamate receptors in the mammalian central nervous system
Ozawa, S., Kamiya, H., & Tsuzuki, K. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(97)00085-3 · Cited by 1,122
Membrane protein folding and oligomerization: the two-stage model
Popot, J. L., & Engelman, D. M. (1990) · Biochemistry · doi:10.1021/bi00469a001 · Cited by 932
Emerging issues of connexin channels: biophysics fills the gap
L. Harris, A. (2001) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583501003705 · Cited by 800
Ionic basis of GABAA receptor channel function in the nervous system
Kaila, K. (1994) · Progress in Neurobiology · doi:10.1016/0301-0082(94)90049-3 · Cited by 670
Acetylcholine Receptor Channel Structure Probed in Cysteine-Substitution Mutants
Akabas, M. H., Stauffer, D. A., Xu, M., & Karlin, A. (1992) · Science · doi:10.1126/science.1384130 · Cited by 665
Conduction and selectivity in potassium channels
Latorre, R., & Miller, C. (1983) · The Journal of Membrane Biology · doi:10.1007/bf01870671 · Cited by 664
Toward a structural basis for the function of nicotinic acetylcholine receptors and their cousins
Karlin, A., & Akabas, M. H. (1995) · Neuron · doi:10.1016/0896-6273(95)90004-7 · Cited by 615
Synthetic Amphiphilic Peptide Models for Protein Ion Channels
Lear, J. D., Wasserman, Z. R., & DeGrado, W. F. (1988) · Science · doi:10.1126/science.2453923 · Cited by 607
GABA receptor mechanisms in the central nervous system
Sivilotti, L., & Nistri, A. (1991) · Progress in Neurobiology · doi:10.1016/0301-0082(91)90036-z · Cited by 554
P2X1 and P2X3 receptors form stable trimers: a novel structural motif of ligand-gated ion channels
Nicke, A. (1998) · The EMBO Journal · doi:10.1093/emboj/17.11.3016 · Cited by 554
Structure of a human synaptic GABAA receptor
Zhu, S., Noviello, C. M., Teng, J., Walsh, R. M., Kim, J. J., & Hibbs, R. E. (2018) · Nature · doi:10.1038/s41586-018-0255-3 · Cited by 549
Eisenman, G., & Horn, R. (1983) · The Journal of Membrane Biology · doi:10.1007/bf01870364 · Cited by 545
Amphipathic analysis and possible formation of the ion channel in an acetylcholine receptor.
Finer-Moore, J., & Stroud, R. M. (1984) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.81.1.155 · Cited by 506
X-ray structure of the human α4β2 nicotinic receptor
Morales-Perez, C. L., Noviello, C. M., & Hibbs, R. E. (2016) · Nature · doi:10.1038/nature19785 · Cited by 398
The structure and function of glutamate receptor ion channels
Madden, D. R. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn725 · Cited by 380
The structure of ion channels in membranes of excitable cells
Unwin, N. (1989) · Neuron · doi:10.1016/0896-6273(89)90235-3 · Cited by 370
Devillers-Thiery, A., Giraudat, J., Bentaboulet, M., & Changeux, J. P. (1983) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.80.7.2067 · Cited by 333
The permeability of endplate channels to monovalent and divalent metal cations.
Adams, D. J., Dwyer, T. M., & Hille, B. (1980) · The Journal of general physiology · doi:10.1085/jgp.75.5.493 · Cited by 331
Self-citationTRPV1 shows dynamic ionic selectivity during agonist stimulation
Chung, M.-K., Güler, A. D., & Caterina, M. J. (2008) · Nature Neuroscience · doi:10.1038/nn.2102 · Cited by 327
Molecular Determinants of Permeation through the Cation Channel TRPV4
Voets, T., Prenen, J., Vriens, J., Watanabe, H., Janssens, A., Wissenbach, U., Bo¨dding, M., Droogmans, G., & Nilius, B. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m204828200 · Cited by 327
Yu, A. S. L., Cheng, M. H., Angelow, S., Günzel, D., Kanzawa, S. A., Schneeberger, E. E., Fromm, M., & Coalson, R. D. (2009) · The Journal of General Physiology · doi:10.1085/jgp.200810154 · Cited by 310
Almers, W., McCleskey, E. W., & Palade, P. T. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015351 · Cited by 306
Structure and gating mechanism of the α7 nicotinic acetylcholine receptor
Noviello, C. M., Gharpure, A., Mukhtasimova, N., Cabuco, R., Baxter, L., Borek, D., Sine, S. M., & Hibbs, R. E. (2021) · Cell · doi:10.1016/j.cell.2021.02.049 · Cited by 299
Non-NMDA receptor-mediated neurotoxicity in cortical culture
Koh, J., Goldberg, M., Hartley, D., & Choi, D. (1990) · The Journal of Neuroscience · doi:10.1523/jneurosci.10-02-00693.1990 · Cited by 290
Crystal structure of coproporphyrinogen III oxidase reveals cofactor geometry of Radical SAM enzymes
Layer, G. (2003) · The EMBO Journal · doi:10.1093/emboj/cdg598 · Cited by 289
Yu, A. S. L., Enck, A. H., Lencer, W. I., & Schneeberger, E. E. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m213286200 · Cited by 274
Properties of the fusion pore that forms during exocytosis of a mast cell secretory vesicle
Spruce, A. E., Breckenridge, L. J., Lee, A. K., & Almers, W. (1990) · Neuron · doi:10.1016/0896-6273(90)90192-i · Cited by 264
Guy, H. R. (1984) · Biophysical Journal · doi:10.1016/s0006-3495(84)84152-1 · Cited by 260
The channel‐blocking action of methonium compounds on rat submandibular ganglion cells
Gurney, A. M., & Rang, H. P. (1984) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.1984.tb10801.x · Cited by 100
Metadata
- Authors
- Dwyer, T. M., Adams, D. J., & Hille, B.
- Venue
- The Journal of general physiology
- Publisher
- Rockefeller University Press
- Published
- 1980-05-01
- Volume
- 75
- Issue
- 5
- Pages
- 469-492
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2140202493
- Cited by
- 363
- References
- 20
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.