Ac electrokinetics: a review of forces in microelectrode structures
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Ac electrokinetics is concerned with the study of the movement and behaviour of particles in suspension when they are subjected to ac electrical fields. The development of new microfabricated electrode structures has meant that particles down to the size of macromolecules have been manipulated, but on this scale forces other than electrokinetic affect particles behaviour. The high electrical fields, which are required to produce sufficient force to move a particle, result in heat dissipation in the medium. This in turn produces thermal gradients, which may give rise to fluid motion through buoyancy, and electrothermal forces. In this paper, the frequency dependency and magnitude of electrothermally induced fluid flow are discussed. A new type of fluid flow is identified for low frequencies (up to 500 kHz). Our preliminary observations indicate that it has its origin in the action of a tangential electrical field on the diffuse double layer of the microfabricated electrodes. The effects of Brownian motion, diffusion and the buoyancy force are discussed in the context of the controlled manipulation of sub-micrometre particles. The orders of magnitude of the various forces experienced by a sub-micrometre latex particle in a model electrode structure are calculated. The results are compared with experiment and the relative influence of each type of force on the overall behaviour of particles is described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Einstein, A. (1905) · Annalen der Physik · doi:10.1002/andp.19053220806 · Cited by 8,265
Principles of colloid and surface chemistry
Hiemenz, P. C., & Rajagopalan, R. (1977) · Cited by 3,500
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 3,118
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786 · cited 1×
“The time-averaged DEP force is given by [1] [5] ¯ F DEP = 1 2 vα∇ ¯ E 2 rms (1) where α is the effective polarizability of the particle, v is the volume of the particle and ∇ ¯ E 2 rms is the gradient of the energy density of the electrical field.”
BackgroundFundamentals of Interface and Colloid Science
Lyklema, J. (1991) · Cited by 1,533
Separation of human breast cancer cells from blood by differential dielectric affinity.
Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.860 · Cited by 680
Einstein, A. (1905) · Annalen der Physik · Cited by 575
Elementary statistical physics
(1958) · Journal of the Franklin Institute · doi:10.1016/0016-0032(58)90491-5 · Cited by 472
ELECTRODE POLARIZATION IMPEDANCE AND MEASUREMENTS IN BIOLOGICAL MATERIALS*
Schwan, H. P. (1968) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1968.tb20349.x · Cited by 368
Cited by
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Active Particles in Complex and Crowded Environments
Bechinger, C., Di Leonardo, R., Löwen, H., Reichhardt, C., Volpe, G., & Volpe, G. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.045006 · Cited by 2,961
Diffuse-charge dynamics in electrochemical systems
Bazant, M. Z., Thornton, K., & Ajdari, A. (2004) · Physical Review E · doi:10.1103/physreve.70.021506 · Cited by 1,053
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Electrohydrodynamics and dielectrophoresis in microsystems: scaling laws
Castellanos, A., Ramos, A., González, A., Green, N. G., & Morgan, H. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/20/023 · Cited by 709
Self-citationMillion-fold Preconcentration of Proteins and Peptides by Nanofluidic Filter
Wang, Y.-C., Stevens, A. L., & Han, J. (2005) · Analytical Chemistry · doi:10.1021/ac050321z · Cited by 618
AC Electric-Field-Induced Fluid Flow in Microelectrodes
Ramos, A., Morgan, H., Green, N. G., & Castellanos, A. (1999) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1999.6346 · Cited by 527
Self-citationSeparation of Submicron Bioparticles by Dielectrophoresis
Morgan, H., Hughes, M. P., & Green, N. G. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76908-0 · Cited by 523
Self-citationSingle cell dielectric spectroscopy
Morgan, H., Sun, T., Holmes, D., Gawad, S., & Green, N. G. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/1/s10 · Cited by 445
Self-citationThermal non-equilibrium transport in colloids
Würger, A. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/12/126601 · Cited by 433
The centrifugal microfluidic Bio-Disk platform
Ducrée, J., Haeberle, S., Lutz, S., Pausch, S., Stetten, F. V., & Zengerle, R. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/7/s07 · Cited by 405
Green, N. G., Ramos, A., González, A., Morgan, H., & Castellanos, A. (2002) · Physical Review E · doi:10.1103/physreve.66.026305 · Cited by 404
Self-citationRapid Isolation and Detection of Exosomes and Associated Biomarkers from Plasma
Ibsen, S. D., Wright, J., Lewis, J. M., Kim, S., Ko, S.-Y., Ong, J., Manouchehri, S., Vyas, A., Akers, J., Chen, C. C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b00549 · Cited by 381
On-chip micromanipulation and assembly of colloidal particles by electric fields
Velev, O. D., & Bhatt, K. H. (2006) · Soft Matter · doi:10.1039/b605052b · Cited by 361
Dielectric mixtures: electrical properties and modeling
Tuncer, E., Serdyuk, Y. V., & Gubanski, S. M. (2002) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2002.1038664 · Cited by 314
Remotely powered self-propelling particles and micropumps based on miniature diodes
Chang, S. T., Paunov, V. N., Petsev, D. N., & Velev, O. D. (2007) · Nature Materials · doi:10.1038/nmat1843 · Cited by 314
Dielectrophoresis for manipulation of micro/nano particles in microfluidic systems
Zhang, C., Khoshmanesh, K., Mitchell, A., & Kalantar-zadeh, K. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2922-6 · Cited by 305
Artificial cilia for active micro-fluidic mixing
Toonder, J. D., Bos, F., Broer, D., Filippini, L., Gillies, M., de Goede, J., Mol, T., Reijme, M., Talen, W., Wilderbeek, H., et al. (2008) · Lab on a Chip · doi:10.1039/b717681c · Cited by 296
AC electrokinetics: applications for nanotechnology
Hughes, M. P. (2000) · Nanotechnology · doi:10.1088/0957-4484/11/2/314 · Cited by 290
Electrothermally induced fluid flow on microelectrodes
Green, N. G., Ramos, A., González, A., Castellanos, A., & Morgan, H. (2001) · Journal of Electrostatics · doi:10.1016/s0304-3886(01)00132-2 · Cited by 272
Self-citationElectrokinetics in Micro Devices for Biotechnology Applications
Wong, P. K., Wang, T.-H., Deval, J. H., & Ho, C.-M. (2004) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2004.828659 · Cited by 254
Surface Conductance Induced Dielectrophoresis of Semiconducting Single-Walled Carbon Nanotubes
Krupke, R., Hennrich, F., Kappes, M. M., & v. Löhneysen, H. (2004) · Nano Letters · doi:10.1021/nl0493794 · Cited by 246
Ermolina, I., & Morgan, H. (2005) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2004.11.003 · Cited by 241
Self-citationDielectrophoresis of Submicrometer Latex Spheres. 1. Experimental Results
Green, N. G., & Morgan, H. (1999) · The Journal of Physical Chemistry B · doi:10.1021/jp9829849 · Cited by 239
Self-citationAc electrokinetics: a survey of sub-micrometre particle dynamics
Green, N. G., Ramos, A., & Morgan, H. (2000) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/33/6/308 · Cited by 230
Self-citationSimple model for the electric field and spatial distribution of ions in a microdroplet
Chamberlayne, C. F., & Zare, R. N. (2020) · The Journal of Chemical Physics · doi:10.1063/5.0006550 · Cited by 214
Dielectrophoretic Traps for Single-Particle Patterning
Rosenthal, A., & Voldman, J. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.049684 · Cited by 210
“The power generation per unit volume of the media (W) is defined by (Ramos et al., 1998):”
BackgroundElectronic manipulation of DNA, proteins, and nanoparticles for potential circuit assembly
Zheng, L., Brody, J. P., & Burke, P. J. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.03.029 · Cited by 198
“Several recent reviews more thoroughly describe the many applications of DEP at the micron, sub-micron, and nanometer scale (Pethig, 1996; Pethig and Markx, 1997; Zimmermann and Neil, 1996; Ramos et al., 1998; Green et al., 2000; Hughes, 2000; Burke, 2004).”
Trapping Single Molecules by Dielectrophoresis
Hölzel, R., Calander, N., Chiragwandi, Z., Willander, M., & Bier, F. F. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.128102 · Cited by 197
Holding Forces of Single-Particle Dielectrophoretic Traps
Voldman, J., Braff, R. A., Toner, M., Gray, M. L., & Schmidt, M. A. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76035-3 · Cited by 195
“The type of force is dictated by the origin of the charge (thermal or double-layer) and the applied frequency relative to the relaxation frequency of the medium (which has the form /⑀) (Ramos et al., 1998, 1999).”
BackgroundDielectrophoretic Assembly of Nanowires
Liu, Y., Chung, J.-H., Liu, W. K., & Ruoff, R. S. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp061367e · Cited by 183
Dielectrophoresis-Enhanced Plasmonic Sensing with Gold Nanohole Arrays
Barik, A., Otto, L. M., Yoo, D., Jose, J., Johnson, T. W., & Oh, S.-H. (2014) · Nano Letters · doi:10.1021/nl500149h · Cited by 182
Joule heating in electrokinetic flow
Xuan, X. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200700302 · Cited by 182
Matrix Effects—A Challenge toward Automation of Molecular Analysis
Chiu, M. L., Lawi, W., Snyder, S. T., Wong, P. K., Liao, J. C., & Gau, V. (2010) · JALA: Journal of the Association for Laboratory Automation · doi:10.1016/j.jala.2010.02.001 · Cited by 175
Micro-fluidic actuation using magnetic artificial cilia
Fahrni, F., Prins, M. W. J., & van IJzendoorn, L. J. (2009) · Lab on a Chip · doi:10.1039/b908578e · Cited by 169
Electrokinetic Bioprocessor for Concentrating Cells and Molecules
Wong, P. K., Chen, C.-Y., Wang, T.-H., & Ho, C.-M. (2004) · Analytical Chemistry · doi:10.1021/ac049479u · Cited by 168
Electrophoretic methods for separation of nanoparticles
Surugau, N., & Urban, P. L. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900071 · Cited by 167
Microfluidic manipulation with artificial/bioinspired cilia
Toonder, J. M. J. D., & Onck, P. R. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2012.11.005 · Cited by 165
Control and Modeling of the Dielectrophoretic Assembly of On-Chip Nanoparticle Wires
Bhatt, K. H., & Velev, O. D. (2004) · Langmuir · doi:10.1021/la0349976 · Cited by 163
Rajput, A., Varshney, A., Bajaj, R., & Pokharkar, V. (2022) · Molecules · doi:10.3390/molecules27217289 · Cited by 161
“6 MHz to separate extracellular vesicles [72].”
Electrophoretic and Dielectrophoretic Field Gradient Technique for Separating Bioparticles
Pysher, M. D., & Hayes, M. A. (2007) · Analytical Chemistry · doi:10.1021/ac070534j · Cited by 161
A phase field model for multiphase electro-hydrodynamic flow
Lin, Y., Skjetne, P., & Carlson, A. (2012) · International Journal of Multiphase Flow · doi:10.1016/j.ijmultiphaseflow.2012.04.002 · Cited by 159
Particle-localized AC and DC manipulation and electrokinetics
Velev, O. D., Gangwal, S., & Petsev, D. N. (2009) · Annual Reports Section "C" (Physical Chemistry) · doi:10.1039/b803015b · Cited by 158
A three-dimensional dielectrophoretic particle focusing channel for microcytometry applications
Yu, C., Vykoukal, J., Vykoukal, D. M., Schwartz, J. A., Shi, L., & Gascoyne, P. R. C. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.844839 · Cited by 158
“In addition, the temperature rise due to Joule heating could be estimated as [ 29 ], where and are the electrical conductivity and the thermal conductivity of the medium, respectively.”
BackgroundMicrotubule alignment and manipulation using AC electrokinetics
Uppalapati, M., Huang, Y., Jackson, T. N., & Hancock, W. O. (2008) · Small · doi:10.1002/smll.200701088 · Cited by 62
Separation of microalgae with different lipid contents by dielectrophoresis
Deng, Y.-L., Chang, J.-S., & Juang, Y.-J. (2013) · Bioresource Technology · doi:10.1016/j.biortech.2012.11.046 · Cited by 56
Metadata
- Authors
- Ramos, A., Morgan, H., Green, N. G., & Castellanos, A.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 1998-09-21
- Volume
- 31
- Issue
- 18
- Pages
- 2338-2353
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W1976697508
- Cited by
- 1,233
- References
- 17
- FWCI
- 7.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.