A review of microfabrication techniques and dielectrophoretic microdevices for particle manipulation and separation
Open accessThe DOI matches its Crossref record; 179 of the 179 references it cites were found in a registry or an index.
Abstract
The development of lab-on-a-chip (LOC) devices over the past decade has attracted growing interest. LOC devices aim to achieve the miniaturization, integration, automation and parallelization of biological and chemical assays. One of the applications, the ability to effectively and accurately manipulate and separate micro- and nano-scale particles in an aqueous solution, is particularly appealing in biological, chemical and medical fields. Among the technologies that have been developed and implemented in microfluidic microsystems for particle manipulation and separation (such as mechanical, inertial, hydrodynamic, acoustic, optical, magnetic and electrical methodologies), dielectrophoresis (DEP) may prove to be the most popular because of its label-free nature, ability to manipulate neutral bioparticles, analyse with high selectivity and sensitivity, compatibility with LOC devices, and easy and direct interface with electronics. The required spatial electric non-uniformities for the DEP effect can be generated by patterning microelectrode arrays within microchannels, or placing insulating obstacles within a microchannel and curving the microchannels. A wide variety of electrode- and insulator-based DEP microdevices have been developed, fabricated, and successfully employed to manipulate and separate bioparticles (i.e. DNA, proteins, bacteria, viruses, mammalian and yeast cells). This review provides an overview of the state-of-the-art of microfabrication techniques and of the structures of dielectrophoretic microdevices aimed towards different applications. The techniques used for particle manipulation and separation based on microfluidics are provided in this paper. In addition, we also present the theoretical background of DEP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687 · cited 1×
“Among those polymers applied for fabricating microfluidic devices, PDMS is particularly appealing due to its transparency, flexibility, low-cost and compatibility [82,83].”
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329 · cited 1×
“Figure 10 illustrates the fabrication process of a microfluidic device based on PDMS, and the fabricating details could be found elsewhere [84,85].”
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786 · cited 3×
“The particle suspended in liquid also experiences an electrokinetic (EK) effect which is a combination of fluid electroosmosis (EO) and particle electrophoresis (EP) [61].”
BackgroundOptical trapping and manipulation of single cells using infrared laser beams
Ashkin, A., Dziedzic, J. M., & Yamane, T. (1987) · Nature · doi:10.1038/330769a0 · Cited by 2,303 · cited 1×
“(5) Optical tweezers could tether biological molecules to particles, and then capture the particles at the focal point of an electric field gradient, which has been widely used as a tool for the manipulation and trapping of particles [53,54,55], however, its application in microfluidics is still limited due to the com…”
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708 · cited 1×
“(2) Inertial lift forces acting on particles in high-velocity flows have been utilized to manipulate polystyrene particles, cells and bacteria within various-shaped microchannels, such as curved [49], asymmetrically curved [50, 51], spiral [52] microchannels, a microchannel consisting of a focusing, an expansion and c…”
High gradient magnetic cell separation with MACS
Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990) · Cytometry · doi:10.1002/cyto.990110203 · Cited by 1,681 · cited 1×
“Fluorescence-activated cell sorting (FACS) [21,22,23] and magnetic-activated cell sorting (MACS) [24,25,26] utilize fluorophore-conjugated antibodies and magnetic beads conjugated with antibodies to label cell of interests, respectively.”
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647 · cited 1×
“The features of compactness, portability, sensitivity and parallelization make LOC devices beneficial for various applications, including point-of-care (POC) diagnostics [7, 8], drug delivery [9, 10], molecule and material synthesis [11], chemical reaction control and detection [2, 12], cellular process studies [5, 13…”
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634 · cited 1×
“(3) The hydrodynamic technique presumes that particles will follow the fluid streamlines at a low Reynolds number, which has been applied within microchannels having multiple side branch channels [43], a pinched segment [44], or micro-obstacle arrays [45], and the separation of different-sized polystyrene particles [4…”
Review Article—Dielectrophoresis: Status of the theory, technology, and applications
Pethig, R. (2010) · Biomicrofluidics · doi:10.1063/1.3456626 · Cited by 1,270 · cited 1×
“cells, viruses, bacteria, DNA and proteins) in microfluidic systems, which have been reviewed in the relevant literature [11,12,13,14,15,16,17,18].”
Cited by
Particle manipulations in non-Newtonian microfluidics: A review
Lu, X., Liu, C., Hu, G., & Xuan, X. (2017) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2017.04.019 · Cited by 289
Arzt, E., Quan, H., McMeeking, R. M., & Hensel, R. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2021.100823 · Cited by 253
Raman image-activated cell sorting
Nitta, N., Iino, T., Isozaki, A., Yamagishi, M., Kitahama, Y., Sakuma, S., Suzuki, Y., Tezuka, H., Oikawa, M., Arai, F., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17285-3 · Cited by 205
Enrichment and single-cell analysis of circulating tumor cells
Song, Y., Tian, T., Shi, Y., Liu, W., Zou, Y., Khajvand, T., Wang, S., Zhu, Z., & Yang, C. (2017) · Chemical Science · doi:10.1039/c6sc04671a · Cited by 167
Microfluidic Sample Preparation for Single Cell Analysis
Hosic, S., Murthy, S. K., & Koppes, A. N. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04077 · Cited by 166
The revolution of PDMS microfluidics in cellular biology
Banik, S., Uchil, A., Kalsang, T., Chakrabarty, S., Ali, M. A., Srisungsitthisunti, P., Mahato, K. K., Surdo, S., & Mazumder, N. (2023) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2022.2034733 · Cited by 84
“(cell sorting, separating, or trapping) [39].”
Cancer immunotherapy μ-environment LabChip: taking advantage of optoelectronic tweezers
Ke, L.-Y., Kuo, Z.-K., Chen, Y.-S., Yeh, T.-Y., Dong, M., Tseng, H.-W., & Liu, C.-H. (2018) · Lab on a Chip · doi:10.1039/c7lc00963a · Cited by 50
Separation, Characterization, and Handling of Microalgae by Dielectrophoresis
Abt, V., Gringel, F., Han, A., Neubauer, P., & Birkholz, M. (2020) · Microorganisms · doi:10.3390/microorganisms8040540 · Cited by 37
“This IDT electrode design is one of the most classical DEP electrode designs used for trapping [77], as the many interdigitated finger structure can generate arrays of high electric field regions, to which cells can be attracted through a positive DEP force (Figure 5b).”
Metadata
- Authors
- Li, M., Li, W. H., Zhang, J., Alici, G., & Wen, W.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2014-01-08
- Volume
- 47
- Issue
- 6
- Pages
- 063001
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2009910733
- Cited by
- 223
- References
- 179
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.