A review of microfabrication techniques and dielectrophoretic microdevices for particle manipulation and separation
Open accessThe DOI matches its Crossref record; 179 of the 179 references it cites were found in a registry or an index.
Abstract
The development of lab-on-a-chip (LOC) devices over the past decade has attracted growing interest. LOC devices aim to achieve the miniaturization, integration, automation and parallelization of biological and chemical assays. One of the applications, the ability to effectively and accurately manipulate and separate micro- and nano-scale particles in an aqueous solution, is particularly appealing in biological, chemical and medical fields. Among the technologies that have been developed and implemented in microfluidic microsystems for particle manipulation and separation (such as mechanical, inertial, hydrodynamic, acoustic, optical, magnetic and electrical methodologies), dielectrophoresis (DEP) may prove to be the most popular because of its label-free nature, ability to manipulate neutral bioparticles, analyse with high selectivity and sensitivity, compatibility with LOC devices, and easy and direct interface with electronics. The required spatial electric non-uniformities for the DEP effect can be generated by patterning microelectrode arrays within microchannels, or placing insulating obstacles within a microchannel and curving the microchannels. A wide variety of electrode- and insulator-based DEP microdevices have been developed, fabricated, and successfully employed to manipulate and separate bioparticles (i.e. DNA, proteins, bacteria, viruses, mammalian and yeast cells). This review provides an overview of the state-of-the-art of microfabrication techniques and of the structures of dielectrophoretic microdevices aimed towards different applications. The techniques used for particle manipulation and separation based on microfluidics are provided in this paper. In addition, we also present the theoretical background of DEP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687 · cited 1×
“Among those polymers applied for fabricating microfluidic devices, PDMS is particularly appealing due to its transparency, flexibility, low-cost and compatibility [82,83].”
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329 · cited 1×
“Figure 10 illustrates the fabrication process of a microfluidic device based on PDMS, and the fabricating details could be found elsewhere [84,85].”
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786 · cited 3×
“The particle suspended in liquid also experiences an electrokinetic (EK) effect which is a combination of fluid electroosmosis (EO) and particle electrophoresis (EP) [61].”
BackgroundOptical trapping and manipulation of single cells using infrared laser beams
Ashkin, A., Dziedzic, J. M., & Yamane, T. (1987) · Nature · doi:10.1038/330769a0 · Cited by 2,303 · cited 1×
“(5) Optical tweezers could tether biological molecules to particles, and then capture the particles at the focal point of an electric field gradient, which has been widely used as a tool for the manipulation and trapping of particles [53,54,55], however, its application in microfluidics is still limited due to the com…”
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708 · cited 1×
“(2) Inertial lift forces acting on particles in high-velocity flows have been utilized to manipulate polystyrene particles, cells and bacteria within various-shaped microchannels, such as curved [49], asymmetrically curved [50, 51], spiral [52] microchannels, a microchannel consisting of a focusing, an expansion and c…”
High gradient magnetic cell separation with MACS
Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990) · Cytometry · doi:10.1002/cyto.990110203 · Cited by 1,681 · cited 1×
“Fluorescence-activated cell sorting (FACS) [21,22,23] and magnetic-activated cell sorting (MACS) [24,25,26] utilize fluorophore-conjugated antibodies and magnetic beads conjugated with antibodies to label cell of interests, respectively.”
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647 · cited 1×
“The features of compactness, portability, sensitivity and parallelization make LOC devices beneficial for various applications, including point-of-care (POC) diagnostics [7, 8], drug delivery [9, 10], molecule and material synthesis [11], chemical reaction control and detection [2, 12], cellular process studies [5, 13…”
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634 · cited 1×
“(3) The hydrodynamic technique presumes that particles will follow the fluid streamlines at a low Reynolds number, which has been applied within microchannels having multiple side branch channels [43], a pinched segment [44], or micro-obstacle arrays [45], and the separation of different-sized polystyrene particles [4…”
Review Article—Dielectrophoresis: Status of the theory, technology, and applications
Pethig, R. (2010) · Biomicrofluidics · doi:10.1063/1.3456626 · Cited by 1,270 · cited 1×
“cells, viruses, bacteria, DNA and proteins) in microfluidic systems, which have been reviewed in the relevant literature [11,12,13,14,15,16,17,18].”
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124 · cited 1×
“1 Introduction The development of microfluidic platforms is heading towards the miniaturisation, integration, and automation of biological and chemical assays [1,2].”
Droplet microfluidics for high-throughput biological assays
Guo, M. T., Rotem, A., Heyman, J. A., & Weitz, D. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21147e · Cited by 1,040
AC electrokinetics : colloids and nanoparticles
Morgan, H., & Green, N. G. (2002) · Thammasat University Digital Collections · Cited by 1,032
Multiphase microfluidics: from flow characteristics to chemical and materials synthesis
Günther, A., & Jensen, K. F. (2006) · Lab Chip · doi:10.1039/b609851g · Cited by 983 · cited 1×
“The features of compactness, portability, sensitivity and parallelization make LOC devices beneficial for various applications, including point-of-care (POC) diagnostics [7, 8], drug delivery [9, 10], molecule and material synthesis [11], chemical reaction control and detection [2, 12], cellular process studies [5, 13…”
Dielectrophoresis: The Behavior of Neutral Matter in Nonuniform Electric Fields
Pohl, H. A. (1978) · Medical Entomology and Zoology · Cited by 935
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930 · cited 1×
“To date, a variety of technologies have been developed to manipulate and separate particles in an aqueous solution, including mechanical, inertial, hydrodynamic, acoustic, optical, magnetic, and electrical methodologies [5,6,7].”
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892 · cited 1×
“cells, viruses, bacteria, DNA and proteins) in microfluidic systems, which have been reviewed in the relevant literature [11,12,13,14,15,16,17,18].”
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878 · cited 1×
“Fluorescence-activated cell sorting (FACS) [21,22,23] and magnetic-activated cell sorting (MACS) [24,25,26] utilize fluorophore-conjugated antibodies and magnetic beads conjugated with antibodies to label cell of interests, respectively.”
Particle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826 · cited 2×
“Among these available methods, dielectrophoresis (DEP) has attracted most attention due to its great advantages [8,9].”
Yamada, M., Nakashima, M., & Seki, M. (2004) · Analytical Chemistry · doi:10.1021/ac049863r · Cited by 746 · cited 1×
“(3) The hydrodynamic technique presumes that particles will follow the fluid streamlines at a low Reynolds number, which has been applied within microchannels having multiple side branch channels [43], a pinched segment [44], or micro-obstacle arrays [45], and the separation of different-sized polystyrene particles [4…”
Inertial microfluidics for continuous particle separation in spiral microchannels
Kuntaegowdanahalli, S. S., Bhagat, A. A. S., Kumar, G., & Papautsky, I. (2009) · Lab on a Chip · doi:10.1039/b908271a · Cited by 708 · cited 1×
“(2) Inertial lift forces acting particles in high-velocity flows have been utilized to manipulate polystyrene particles, cells and bacteria within various-shaped microchannels, such as curve [37], asymmetrically curve [38,39], spiral [40] microchannles, a microchannel consisting of a focusing, expansion and collection…”
Separation of human breast cancer cells from blood by differential dielectric affinity.
Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.860 · Cited by 680 · cited 1×
“Other research work on trapping cells and silica beads [98], concentrating embryonic stem cells (ESCs) [99], sorting nano-[100] and micro-particles [101], clones of mouse melanoma B16F10 cells [102], separating cancel cells from blood [103,104], separating dormant Mycobacterium smegmatis from live and dead M.”
Free Flow Acoustophoresis: Microfluidic-Based Mode of Particle and Cell Separation
Petersson, F., Åberg, L., Swärd-Nilsson, A.-M., & Laurell, T. (2007) · Analytical Chemistry · doi:10.1021/ac070444e · Cited by 649 · cited 1×
“There are several reports regarding the application of an ultrasonic standing wave field combined with laminar flow to separate different-sized particles [49,50], blood cells [51], and yeast cells [52].”
Deterministic hydrodynamics: Taking blood apart
Davis, J. A., Inglis, D. W., Morton, K. J., Lawrence, D. A., Huang, L. R., Chou, S. Y., Sturm, J. C., & Austin, R. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605967103 · Cited by 622 · cited 1×
“(3) The hydrodynamic technique presumes that particles will follow the fluid streamlines at a low Reynolds number, which has been applied within microchannels having multiple side branch channels [43], a pinched segment [44], or micro-obstacle arrays [45], and the separation of different-sized polystyrene particles [4…”
Zheng, S., Lin, H., Liu, J.-Q., Balic, M., Datar, R., Cote, R. J., & Tai, Y.-C. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.064 · Cited by 599 · cited 1×
“blood cells [29,30] , plasma [31,32], and circulating tumor cells [33]) mechanically based on size has been achieved by fabricating constriction structures (i.”
Flexible Methods for Microfluidics
Whitesides, G. M., & Stroock, A. D. (2001) · Physics Today · doi:10.1063/1.1387591 · Cited by 595 · cited 1×
“Among those polymers applied for fabricating microfluidic devices, PDMS is particularly appealing due to its transparency, flexibility, low-cost and compatibility [82,83].”
Lab-on-a-Chip: A Revolution in Biological and Medical Sciences.
Figeys, D., & Pinto, D. (2000) · Analytical Chemistry · doi:10.1021/ac002800y · Cited by 562 · cited 1×
“LOC devices are also known as micro total analysis systems (μTAS), which integrate laboratory functions on a single small scale chip [3, 4].”
Separation of Submicron Bioparticles by Dielectrophoresis
Morgan, H., Hughes, M. P., & Green, N. G. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76908-0 · Cited by 523 · cited 4×
“Listeria innocua [112] and yeast cells [113]), and nano-/micro-particles [89,114], capture DNA [115], bacteria [36], polystyrene beads [114,116] and blood erythrocytes [114], capture and release ribosomal RNA (rRNA) [117], separate human colon cancer cells (HT-29 cells) from RBCs [118], characterize and separate C.”
InfluentialContinuous sorting of magnetic cells via on-chip free-flow magnetophoresis
Pamme, N., & Wilhelm, C. (2006) · Lab on a Chip · doi:10.1039/b604542a · Cited by 497 · cited 1×
“The separation of red and white blood cells from whole blood [56,57,58], and living cells loaded with magnetic nanoparticles [59] have been achieved.”
Revisiting lab-on-a-chip technology for drug discovery
Neužil, P., Giselbrecht, S., Länge, K., Huang, T. J., & Manz, A. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3799 · Cited by 487 · cited 1×
“The features of compactness, portability, sensitivity and parallelization make LOC devices beneficial for various applications, including point-of-care (POC) diagnostics [7, 8], drug delivery [9, 10], molecule and material synthesis [11], chemical reaction control and detection [2, 12], cellular process studies [5, 13…”
Dielectrophoretic Concentration and Separation of Live and Dead Bacteria in an Array of Insulators
Lapizco-Encinas, B. H., Simmons, B. A., Cummings, E. B., & Fintschenko, Y. (2004) · Analytical Chemistry · doi:10.1021/ac034804j · Cited by 483 · cited 1×
“24) were embedded in the microchannels to manipulate a variety of particles, such as DNA [188,189,190], protein [191,192], virus [193], live and dead bacteria [187,194].”
The Intriguing Superconductivity of Strontium Ruthenate
Maeno, Y., Rice, T. M., & Sigrist, M. (2001) · Physics Today · doi:10.1063/1.1349611 · Cited by 434
Dielectrophoretic Sorting of Particles and Cells in a Microsystem
Fiedler, S., Shirley, S. G., Schnelle, T., & Fuhr, G. (1998) · Analytical Chemistry · doi:10.1021/ac971063b · Cited by 432 · cited 1×
“cells, viruses, bacteria, DNA and proteins) in microfluidic systems, which have been reviewed in the relevant literature [11,12,13,14,15,16,17,18].”
Equilibrium Separation and Filtration of Particles Using Differential Inertial Focusing
Di Carlo, D., Edd, J. F., Irimia, D., Tompkins, R. G., & Toner, M. (2008) · Analytical Chemistry · doi:10.1021/ac702283m · Cited by 413 · cited 1×
“(2) Inertial lift forces acting particles in high-velocity flows have been utilized to manipulate polystyrene particles, cells and bacteria within various-shaped microchannels, such as curve [37], asymmetrically curve [38,39], spiral [40] microchannles, a microchannel consisting of a focusing, expansion and collection…”
Dielectrophoresis in microfluidics technology
Çetin, B., & Li, D. (2011) · ELECTROPHORESIS · doi:10.1002/elps.201100167 · Cited by 411 · cited 3×
“Alternatively, 3D microelectrode structures [14] such as extruded vertical electrodes on the bottom, top-bottom patterned, and sidewall patterned microelectrodes have been developed and fabricated using more complicated techniques (i.”
Dielectrophoretic separation of cancer cells from blood
Gascoyne, P. R. C., Wang, X.-B., Huang, Y., & Becker, F. F. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.585856 · Cited by 406
Strategies for dielectrophoretic separation in laboratory-on-a-chip systems
Hughes, M. P. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200208)23:16<2569::aid-elps2569>3.0.co;2-m · Cited by 401 · cited 2×
“Among these available methods, dielectrophoresis (DEP) has attracted most attention due to its great advantages [8,9].”
Cummings, E. B., & Singh, A. K. (2003) · Analytical Chemistry · doi:10.1021/ac0340612 · Cited by 375 · cited 1×
“It was demonstrated that the shape of the post and angle of the array with respect to applied electric field play an important role in the patterns of filaments and trapped zones [195], and the conductivity and PH value of the”
Wolff, A., Perch-Nielsen, I. R., Larsen, U. D., Friis, P., Goranovic, G., Poulsen, C. R., Kutter, J. P., & Telleman, P. (2003) · Lab on a Chip · doi:10.1039/b209333b · Cited by 356 · cited 1×
“Fluorescence-activated cell sorting (FACS) [21,22,23] and magnetic-activated cell sorting (MACS) [24,25,26] utilize fluorophore-conjugated antibodies and magnetic beads conjugated with antibodies to label cell of interests, respectively.”
Continuous microfluidic immunomagnetic cell separation
Inglis, D. W., Riehn, R., Austin, R. H., & Sturm, J. C. (2004) · Applied Physics Letters · doi:10.1063/1.1823015 · Cited by 353 · cited 1×
“Fluorescence-activated cell sorting (FACS) [21,22,23] and magnetic-activated cell sorting (MACS) [24,25,26] utilize fluorophore-conjugated antibodies and magnetic beads conjugated with antibodies to label cell of interests, respectively.”
Lapizco‐Encinas, B. H., Simmons, B. A., Cummings, E. B., & Fintschenko, Y. (2004) · ELECTROPHORESIS · doi:10.1002/elps.200405899 · Cited by 347 · cited 1×
“24) were embedded in the microchannels to manipulate a variety of particles, such as DNA [188,189,190], protein [191,192], virus [193], live and dead bacteria [187,194].”
Continuous scalable blood filtration device using inertial microfluidics
Mach, A. J., & Di Carlo, D. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22833 · Cited by 334 · cited 1×
“(2) Inertial lift forces acting particles in high-velocity flows have been utilized to manipulate polystyrene particles, cells and bacteria within various-shaped microchannels, such as curve [37], asymmetrically curve [38,39], spiral [40] microchannles, a microchannel consisting of a focusing, expansion and collection…”
Separation of lipids from blood utilizing ultrasonic standing waves in microfluidic channels
Petersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T. (2004) · The Analyst · doi:10.1039/b409139f · Cited by 330 · cited 1×
“There are several reports regarding the application of an ultrasonic standing wave field combined with laminar flow to separate different-sized particles [49,50], blood cells [51], and yeast cells [52].”
A Microfabrication-Based Dynamic Array Cytometer
Voldman, J., Gray, M. L., Toner, M., & Schmidt, M. A. (2002) · Analytical Chemistry · doi:10.1021/ac0256235 · Cited by 328 · cited 2×
“19a, Voldman et al proposed the use of extruded gold posts in a quadrupolar arrangement fabricated by electroplating, and achieved the trapping of polystyrene microparticles [169] and HL60 cells [166].”
Dielectrophoresis-Based Sample Handling in General-Purpose Programmable Diagnostic Instruments
Gascoyne, P. R. C., & Vykoukal, J. V. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820535 · Cited by 321 · cited 2×
“As the dielectric properties represent many structural, morphological and chemical characteristics of the particles, DEP offers a more selective and sensitive analysis of biological samples [63].”
Gagnon, Z. R. (2011) · ELECTROPHORESIS · doi:10.1002/elps.201100060 · Cited by 317 · cited 1×
“cells, viruses, bacteria, DNA and proteins) in microfluidic systems, which have been reviewed in the relevant literature [11,12,13,14,15,16,17,18].”
A cmos chip for individual cell manipulation and detection
Manaresi, N., Romani, A., Medoro, G., Altomare, L., Leonardi, A., Tartagni, M., & Guerrieri, R. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.819171 · Cited by 314
Li, H. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(02)00172-7 · Cited by 314 · cited 2×
“Listeria innocua [112] and yeast cells [113]), and nano-/micro-particles [89,114], capture DNA [115], bacteria [36], polystyrene beads [114,116] and blood erythrocytes [114], capture and release ribosomal RNA (rRNA) [117], separate human colon cancer cells (HT-29 cells) from RBCs [118], characterize and separate C.”
Pethig, R., Huang, Y., Wang, X.-B., & Burt, J. P. H. (1992) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/25/5/022 · Cited by 312 · cited 1×
“Other research work on trapping cells and silica beads [98], concentrating embryonic stem cells (ESCs) [99], sorting nano-[100] and micro-particles [101], clones of mouse melanoma B16F10 cells [102], separating cancel cells from blood [103,104], separating dormant Mycobacterium smegmatis from live and dead M.”
Dielectrophoresis for manipulation of micro/nano particles in microfluidic systems
Zhang, C., Khoshmanesh, K., Mitchell, A., & Kalantar-zadeh, K. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2922-6 · Cited by 305 · cited 1×
“cells, viruses, bacteria, DNA and proteins) in microfluidic systems, which have been reviewed in the relevant literature [11,12,13,14,15,16,17,18].”
Mohammed, M.-I., & Desmulliez, M. P. Y. (2011) · Lab Chip · doi:10.1039/c0lc00204f · Cited by 304
Selective isolation of live/dead cells using contactless dielectrophoresis (cDEP)
Shafiee, H., Sano, M. B., Henslee, E. A., Caldwell, J. L., & Davalos, R. V. (2010) · Lab on a Chip · doi:10.1039/b920590j · Cited by 288 · cited 1×
“This technique demonstrated the trapping of THP-1 human Leukemia monocytes and MCF-7 breast cancer cells [86], and also the sorting of live and dead THP-1 cells [228].”
Integrated Cell Isolation and Polymerase Chain Reaction Analysis Using Silicon Microfilter Chambers
Wilding, P., Kricka, L. J., Cheng, J., Hvichia, G., Shoffner, M. A., & Fortina, P. (1998) · Analytical Biochemistry · doi:10.1006/abio.1997.2530 · Cited by 276 · cited 1×
“weir [34], pillar [35], and through-holes [36]) within the microchannels.”
DC-Dielectrophoretic separation of biological cells by size
Kang, Y., Li, D., Kalams, S. A., & Eid, J. E. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9130-y · Cited by 276 · cited 1×
“Size-based separation of biological cells [202] and DNA molecules [203] was achieved using hurdles, and the triangular hurdle was developed to reduce the constriction gap region and its accompanying adverse effect on live cells.”
Electrothermally induced fluid flow on microelectrodes
Green, N. G., Ramos, A., González, A., Castellanos, A., & Morgan, H. (2001) · Journal of Electrostatics · doi:10.1016/s0304-3886(01)00132-2 · Cited by 272
Dielectrophoresis of carbon nanotubes using microelectrodes: a numerical study
Dimaki, M., & Bøggild, P. (2004) · Nanotechnology · doi:10.1088/0957-4484/15/8/039 · Cited by 263 · cited 1×
“When a dc field (the frequency is zero) is applied (usually via electrodes placed at inlets and outlets) the DEP force expression (equation (5)) remains the same but the CM factor only depends on the electrical conductivities of the particle and the medium, and is simplified into equation (4a) [28, 76].”
Cheng, I.-F., Chang, H.-C., Hou, D., & Chang, H.-C. (2007) · Biomicrofluidics · doi:10.1063/1.2723669 · Cited by 262 · cited 2×
“Traditionally, the fabrication process of DEP-based microdevices with three-dimensional (3D) microelectrode arrays patterned on top and bottom surface of the substrate always involves: patterning of planar electrode arrays on both substrates, manufacturing microchannel structure of SU-8 photoresist, and application of…”
Dielectrophoresis switching with vertical sidewall electrodes for microfluidic flow cytometry
Wang, L., Flanagan, L. A., Jeon, N. L., Monuki, E. S., & Lee, A. P. (2007) · Lab on a Chip · doi:10.1039/b705386j · Cited by 249 · cited 1×
“20), and successfully switched polystyrene particles and mouse neural stem cells [178], and separated human kidney cells (HEK293) from N115 mouse neuroblastoma cells as well as polystyrene microbeads from modified HEK293 cells [175].”
Particle Focusing Mechanisms in Curving Confined Flows
Gossett, D. R., & Carlo, D. D. (2009) · Analytical Chemistry · doi:10.1021/ac901306y · Cited by 246 · cited 1×
“(2) Inertial lift forces acting particles in high-velocity flows have been utilized to manipulate polystyrene particles, cells and bacteria within various-shaped microchannels, such as curve [37], asymmetrically curve [38,39], spiral [40] microchannles, a microchannel consisting of a focusing, expansion and collection…”
Park, J.-S., Song, S.-H., & Jung, H.-I. (2009) · Lab Chip · doi:10.1039/b813952k · Cited by 239 · cited 1×
“(2) Inertial lift forces acting particles in high-velocity flows have been utilized to manipulate polystyrene particles, cells and bacteria within various-shaped microchannels, such as curve [37], asymmetrically curve [38,39], spiral [40] microchannles, a microchannel consisting of a focusing, expansion and collection…”
Contactless dielectrophoresis: a new technique for cell manipulation
Shafiee, H., Caldwell, J. L., Sano, M. B., & Davalos, R. V. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9317-5 · Cited by 236 · cited 7×
“5.2.3 Contactless Shafiee et al [86] developed a technique called contactless DEP (Fig.”
MethodInfluentialLab-on-a-chip: a component view
Lim, Y. C., Kouzani, A. Z., & Duan, W. (2010) · Microsystem Technologies · doi:10.1007/s00542-010-1141-6 · Cited by 220
Antibody-independent isolation of circulating tumor cells by continuous-flow dielectrophoresis
Shim, S., Stemke-Hale, K., Tsimberidou, A. M., Noshari, J., Anderson, T. E., & Gascoyne, P. R. C. (2013) · Biomicrofluidics · doi:10.1063/1.4774304 · Cited by 215 · cited 1×
“With the same DEP-FFF method, isolation of circulating tumor cells (CTCs) from blood was accomplished by Shim et al [126,127].”
Design, fabrication and characterization of drug delivery systems based on lab-on-a-chip technology
Nguyen, N.-T., Shaegh, S. A. M., Kashaninejad, N., & Phan, D.-T. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.05.008 · Cited by 210
Electrokinetic motion of particles and cells in microchannels
Kang, Y., & Li, D. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0408-7 · Cited by 210 · cited 1×
“To date, a variety of technologies have been developed to manipulate and separate particles in an aqueous solution, including mechanical, inertial, hydrodynamic, acoustic, optical, magnetic, and electrical methodologies [5,6,7].”
Dielectrophoretic Traps for Single-Particle Patterning
Rosenthal, A., & Voldman, J. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.049684 · Cited by 210 · cited 1×
“Other planar designs Negative DEP microwells consisting of a square electrode and a line electrode have been utilized to pattern single particles, such as polystyrene beads of varies sizes [142], and adherent (HeLa) and non-adherent (HL60) cells [143].”
VanDelinder, V., & Groisman, A. (2006) · Analytical Chemistry · doi:10.1021/ac060042r · Cited by 209 · cited 1×
“blood cells [29,30] , plasma [31,32], and circulating tumor cells [33]) mechanically based on size has been achieved by fabricating constriction structures (i.”
An Equilibrium Method for Continuous-Flow Cell Sorting Using Dielectrophoresis
Vahey, M. D., & Voldman, J. (2008) · Analytical Chemistry · doi:10.1021/ac7020568 · Cited by 203 · cited 5×
“The details of fabricating extruded gold electrodes from the bottom substrates can be found in the work of Voldman et al [72].”
InfluentialTrapping Single Molecules by Dielectrophoresis
Hölzel, R., Calander, N., Chiragwandi, Z., Willander, M., & Bier, F. F. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.128102 · Cited by 197 · cited 1×
“The patterning and collection of mammalian virus (HSV-1) by both positive and negative DEP at different frequencies was accomplished by Hughes et al [95] as well as the trapping of protein molecules [96] and bacterial spores [97] have been achieved in a triangular polynomial electrode.”
Microfabrication technologies in dielectrophoresis applications—A review
Martinez‐Duarte, R. (2012) · ELECTROPHORESIS · doi:10.1002/elps.201200242 · Cited by 194 · cited 2×
“Martinez-Duarte et al [73] provided the details of fabricating carbon electrodes for dielectrophoresis applications.”
A Scalable Addressable Positive-Dielectrophoretic Cell-Sorting Array
Taff, B. M., & Voldman, J. (2005) · Analytical Chemistry · doi:10.1021/ac0513616 · Cited by 191 · cited 6×
“The details of fabricating extruded gold electrodes from the bottom substrates can be found in the work of Voldman et al [72].”
InfluentialSeparation of tumor cells with dielectrophoresis-based microfluidic chip
Alshareef, M., Metrakos, N., Juarez Perez, E., Azer, F., Yang, F., Yang, X., & Wang, G. (2013) · Biomicrofluidics · doi:10.1063/1.4774312 · Cited by 188 · cited 2×
“Polynomial Yang et al [90] proposed a pair of triangular microelectrodes to manipulate and isolate the colorectal cancer HCT116 cells from the mixture with human embryonic kidney 293 HEK293 and E. coli cells, and similar electrode structure was applied by Alshareef et al [91] to isolate and separate human cancer cells.”
Continuous separation of microparticles by size with Direct current‐dielectrophoresis
Kang, K. H., Kang, Y., Xuan, X., & Li, D. (2006) · ELECTROPHORESIS · doi:10.1002/elps.200500558 · Cited by 188 · cited 3×
“Kang et al [199,201] designed a rectangular insulating hurdle within a straight microchannel to separate particles by size (Fig.”
Field-flow fractionation in bioanalysis: A review of recent trends
Roda, B., Zattoni, A., Reschiglian, P., Moon, M. H., Mirasoli, M., Michelini, E., & Roda, A. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.01.015 · Cited by 183 · cited 1×
“To date, a variety of technologies have been developed to manipulate and separate particles in an aqueous solution, including mechanical, inertial, hydrodynamic, acoustic, optical, magnetic, and electrical methodologies [5,6,7].”
An insulator-based (electrodeless) dielectrophoretic concentrator for microbes in water
Lapizco-Encinas, B. H., Davalos, R. V., Simmons, B. A., Cummings, E. B., & Fintschenko, Y. (2005) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2005.04.027 · Cited by 183 · cited 1×
“24) were embedded in the microchannels to manipulate a variety of particles, such as DNA [188,189,190], protein [191,192], virus [193], live and dead bacteria [187,194].”
Piacentini, N., Mernier, G., Tornay, R., & Renaud, P. (2011) · Biomicrofluidics · doi:10.1063/1.3640045 · Cited by 177 · cited 2×
“Figure 23 Liquid microelectrode array on the sidewall: (a) schematic of chip design and behaviour of RBCs, WBCs and PLTs under the DEP effect in the chip, and (b) experimental image showing the separation of RBCs and PLTs in the design [177].”
Trapping of DNA by dielectrophoresis
Asbury, C. L., Diercks, A. H., & van den Engh, G. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200208)23:16<2658::aid-elps2658>3.0.co;2-o · Cited by 177
Continuous magnetophoretic separation of blood cells in microdevice format
Han, K.-H., & Frazier, A. B. (2004) · Journal of Applied Physics · doi:10.1063/1.1803628 · Cited by 173 · cited 1×
“The separation of red and white blood cells from whole blood [56,57,58], and living cells loaded with magnetic nanoparticles [59] have been achieved.”
Continuous Dielectrophoretic Size-Based Particle Sorting
Kralj, J. G., Lis, M. T. W., Schmidt, M. A., & Jensen, K. F. (2006) · Analytical Chemistry · doi:10.1021/ac0601314 · Cited by 171 · cited 1×
“Kralj et al [130] used an array of slanted, interdigitated electrodes to separate polystyrene microspheres based on size.”
Hunt, T. P., Issadore, D., & Westervelt, R. M. (2008) · Lab Chip · doi:10.1039/b710928h · Cited by 169 · cited 1×
“tumor cells [147] and yeast cells [148]) and droplets [148,149], and sorting individual live cells from an unlabelled population [150] have been achieved in integrated circuit chips with a grid pattern of electrode arrays.”
Negative DEP traps for single cell immobilisation
Thomas, R. S., Morgan, H., & Green, N. G. (2009) · Lab on a Chip · doi:10.1039/b819267g · Cited by 166 · cited 2×
“Ring-shaped electrodes proposed by Thomas et al [151,152] were utilized to isolate, concentrate and separate microparticles and human osteoblast-like cells, and multiple concentric ring-shaped”
Vykoukal, J. V., Vykoukal, D. M., Freyberg, S., Alt, E., & Gascoyne, P. R. C. (2008) · Lab on a Chip · doi:10.1039/b717043b · Cited by 165 · cited 1×
“Vykoukal et al [125] proposed a dielectrophoretic field-flow fractionation (DEPFFF) microseparator with a flex interdigitated electrode array to enrich stem cells from enzyme-digested adipose tissue, which was fabricated using a scalable and low-cost hybrid flex-circuit method.”
Hawkins, B. G., Smith, A. E., Syed, Y. A., & Kirby, B. J. (2007) · Analytical Chemistry · doi:10.1021/ac0707277 · Cited by 162 · cited 2×
“As the motion of a particle depends on the ratio between the electrokinetic effect (the combined effect of electrophoresis and electroosmosis) and the DEP effect, such structures successfully trapped and deflected nano- [200] and micro-scale [207] polystyrene particles, and selectively concentrated and separated B.”
Electrophoretic and Dielectrophoretic Field Gradient Technique for Separating Bioparticles
Pysher, M. D., & Hayes, M. A. (2007) · Analytical Chemistry · doi:10.1021/ac070534j · Cited by 161 · cited 2×
“epidermidis in a saw-tooth microchannel [213].”
Continuous dielectrophoretic cell separation microfluidic device
Li, Y., Dalton, C., Crabtree, H. J., Nilsson, G., & Kaler, K. V. I. S. (2007) · Lab Chip · doi:10.1039/b613344d · Cited by 158 · cited 1×
“Listeria innocua [112] and yeast cells [113]), and nano-/micro-particles [89,114], capture DNA [115], bacteria [36], polystyrene beads [114,116] and blood erythrocytes [114], capture and release ribosomal RNA (rRNA) [117], separate human colon cancer cells (HT-29 cells) from RBCs [118], characterize and separate C.”
Manipulation of herpes simplex virus type 1 by dielectrophoresis
Hughes, M. P., Morgan, H., Rixon, F. J., Burt, J. P. H., & Pethig, R. (1998) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(98)00058-0 · Cited by 158 · cited 1×
“The patterning and collection of mammalian virus (HSV-1) by both positive and negative DEP at different frequencies was accomplished by Hughes et al [95] as well as the trapping of protein molecules [96] and bacterial spores [97] have been achieved in a triangular polynomial electrode.”
A three-dimensional dielectrophoretic particle focusing channel for microcytometry applications
Yu, C., Vykoukal, J., Vykoukal, D. M., Schwartz, J. A., Shi, L., & Gascoyne, P. R. C. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.844839 · Cited by 158 · cited 1×
“Yu et al [165] utilized a microelectrode array patterned on the circumference of an elliptic-like microchannel to focus microbeads and human leukemia HL60 cells towards the centre of the channel.”
Characterization and optimization of liquid electrodes for lateral dielectrophoresis
Demierre, N., Braschler, T. M., Linderholm, P., et al. (2007) · Lab on a Chip · doi:10.1039/b612866a · Cited by 153 · cited 2×
“focus polystyrene microparticles [89], sort viable and non-”
Martínez‐Duarte, R., Gorkin, R. A., III, Abi‐Samra, K., & Madou, M. J. (2010) · Lab on a Chip · doi:10.1039/b925456k · Cited by 149 · cited 2×
“cereus bacteria, while Martinez-Duarte et al [184] trapped yeast cells from the mixture with polystyrene particles.”
Highly-integrated lab-on-chip system for point-of-care multiparameter analysis
Schumacher, S., Nestler, J., Otto, T., Wegener, M., Ehrentreich-Förster, E., Michel, D., Wunderlich, K., Palzer, S., Sohn, K., Weber, A., et al. (2012) · Lab Chip · doi:10.1039/c1lc20693a · Cited by 148
VanDelinder, V., & Groisman, A. (2007) · Analytical Chemistry · doi:10.1021/ac061659b · Cited by 148 · cited 1×
“blood cells [29,30] , plasma [31,32], and circulating tumor cells [33]) mechanically based on size has been achieved by fabricating constriction structures (i.”
Smistrup, K., Hansen, O. P., Bruus, H., et al. (2005) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2005.01.079 · Cited by 146 · cited 1×
“Fluorescence-activated cell sorting (FACS) [21,22,23] and magnetic-activated cell sorting (MACS) [24,25,26] utilize fluorophore-conjugated antibodies and magnetic beads conjugated with antibodies to label cell of interests, respectively.”
Wang, L., Lu, J., Marchenko, S., Monuki, E. S., Flanagan, L. A., & Lee, A. P. (2009) · Electrophoresis · doi:10.1002/elps.200800637 · Cited by 142 · cited 2×
“Figure 20 Microelectrodes arrays patterned along the microchannel sidewalls: (a) schematic of separation principle by an array of vertically interdigitated on both microchannel sidewalls, (b) schematic illustration of the balance of two DEP forces acting on cells in the separation zone, (c) experimental image of sorti…”
Green, N. G., & Morgan, H. (1998) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/31/7/002 · Cited by 138 · cited 1×
“Other research work on trapping cells and silica beads [98], concentrating embryonic stem cells (ESCs) [99], sorting nano-[100] and micro-particles [101], clones of mouse melanoma B16F10 cells [102], separating cancel cells from blood [103,104], separating dormant Mycobacterium smegmatis from live and dead M.”
Microfluidic separation of live and dead yeast cells using reservoir-based dielectrophoresis
Patel, S., Showers, D., Vedantam, P., et al. (2012) · Biomicrofluidics · doi:10.1063/1.4732800 · Cited by 137 · cited 1×
“Recently, Patel et al [212] proposed the use of inherent electric field gradient at the reservoir-channel junction, and achieved the separation of live and dead yeast cells.”
Design and analysis of extruded quadrupolar dielectrophoretic traps
Voldman, J., Toner, M., Gray, M. L., et al. (2002) · Journal of Electrostatics · doi:10.1016/s0304-3886(02)00120-1 · Cited by 137
Protein manipulation with insulator-based dielectrophoresis and direct current electric fields
Lapizco‐Encinas, B. H., Ozuna‐Chacón, S., & Rito‐Palomares, M. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.05.077 · Cited by 135 · cited 1×
“24) were embedded in the microchannels to manipulate a variety of particles, such as DNA [188,189,190], protein [191,192], virus [193], live and dead bacteria [187,194].”
Effects of dc-dielectrophoretic force on particle trajectories in microchannels
Kang, K. H., Xuan, X. S., Kang, Y., et al. (2006) · Journal of Applied Physics · doi:10.1063/1.2180430 · Cited by 134 · cited 2×
“Kang et al [199,201] designed a rectangular insulating hurdle within a straight microchannel to separate particles by size (Fig.”
nDEP microwells for single-cell patterning in physiological media
Mittal, N., Rosenthal, A. D., & Voldman, J. (2007) · Lab on a Chip · doi:10.1039/b706342c · Cited by 132 · cited 1×
“Other planar designs Negative DEP microwells consisting of a square electrode and a line electrode have been utilized to pattern single particles, such as polystyrene beads of varies sizes [142], and adherent (HeLa) and non-adherent (HL60) cells [143].”
Lewpiriyawong, N., Kandaswamy, K., Yang, C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202137y · Cited by 130 · cited 1×
“coli from similar-size latex particles, and also separated live and dead yeast cells [180].”
Shim, S., Stemke‐Hale, K., Noshari, J., Becker, F. F., & Gascoyne, P. R. C. (2013) · Biomicrofluidics · doi:10.1063/1.4774307 · Cited by 129 · cited 1×
“With the same DEP-FFF method, isolation of circulating tumor cells (CTCs) from blood was accomplished by Shim et al [126,127].”
Selective concentration of human cancer cells using contactless dielectrophoresis
Henslee, E. A., Sano, M. B., Rojas, A. D., et al. (2011) · Electrophoresis · doi:10.1002/elps.201100081 · Cited by 129 · cited 1×
“Moreover, this technique was utilized to selectively concentrate human breast cancer cells [229], isolate human leukemia cells from erythrocytes[230], separate tumor initiating cells (TICs) from non-TICs [231], and mouse ovarian surface epithelial (MOSE) cells from fibroblasts and macrophages [232], and characterize t…”
Electrodeless dielectrophoresis for bioanalysis: Theory, devices and applications
Regtmeier, J., Eichhorn, R., Viefhues, M., Bogunovic, L., & Anselmetti, D. (2011) · Electrophoresis · doi:10.1002/elps.201100055 · Cited by 125
Lewpiriyawong, N., Yang, C., & Lam, Y. C. (2010) · Electrophoresis · doi:10.1002/elps.201000087 · Cited by 125 · cited 6×
“Lewpiriyawong et al developed a novel microfluidic device with conducting PDMS composites as sidewall electrodes (Fig.”
InfluentialIsolation of prostate tumor initiating cells (TICs) through their dielectrophoretic signature
Salmanzadeh, A., Romero, L. M., Shafiee, H., Gallo‐Villanueva, R. C., Stremler, M. A., Cramer, S. D., & Davalos, R. V. (2011) · Lab on a Chip · doi:10.1039/c1lc20701f · Cited by 124 · cited 1×
“Moreover, this technique was utilized to selectively concentrate human breast cancer cells [229], isolate human leukemia cells from erythrocytes[230], separate tumor initiating cells (TICs) from non-TICs [231], and mouse ovarian surface epithelial (MOSE) cells from fibroblasts and macrophages [232], and characterize t…”
Han, K.-H., & Frazier, A. B. (2008) · Lab on a Chip · doi:10.1039/b802321b · Cited by 124 · cited 1×
“Han and Frazier [134] achieved the separation of red blood cells (RBCs) and white blood cells (WBCs) in both divergent and convergent interdigitated electrode arrays.”
A novel approach to dielectrophoresis using carbon electrodes
Martínez‐Duarte, R., Renaud, P., & Madou, M. J. (2011) · Electrophoresis · doi:10.1002/elps.201100059 · Cited by 123 · cited 3×
“Figure 5 Fabrication process flow for a DEP-based microdevice with carbon electrodes [73].”
Kang, Y., Çetin, B., Wu, Z., et al. (2008) · Electrochimica Acta · doi:10.1016/j.electacta.2008.09.062 · Cited by 120 · cited 3×
“Kang et al [199,201] designed a rectangular insulating hurdle within a straight microchannel to separate particles by size (Fig.”
Two-Dimensional Manipulation and Orientation of Actin−Myosin Systems with Dielectrophoresis
Asokan, S. B., Jawerth, L. M., Carroll, R. L., Cheney, R. E., Washburn, S., & Superfine, R. (2003) · Nano Letters · doi:10.1021/nl0259434 · Cited by 117 · cited 2×
“Asokan et al [92] utilized the electrode design to pattern actin on a substrate, and direct its motion on myosin substrates along the electric field lines.”
MethodDielectrophoretic separation of colorectal cancer cells
Yang, F., Yang, X., Jiang, H., et al. (2010) · Biomicrofluidics · doi:10.1063/1.3279786 · Cited by 108 · cited 2×
“Polynomial Yang et al [90] proposed a pair of triangular microelectrodes to manipulate and isolate the colorectal cancer HCT116 cells from the mixture with human embryonic kidney 293 HEK293 and E. coli cells, and similar electrode structure was applied by Alshareef et al [91] to isolate and separate human cancer cells.”
DC-dielectrophoretic separation of microparticles using an oil droplet obstacle
Barbulovic-Nad, I., Xuan, X. S., Lee, J. S. H., et al. (2005) · Lab on a Chip · doi:10.1039/b513183a · Cited by 105 · cited 1×
“Instead of insulating solid obstacles, an oil droplet [206] and oil meniscus [88] were used to create spatial non-uniformities of electric field.”
Lateral-driven continuous magnetophoretic separation of blood cells
Jung, J.-H., & Han, K.-H. (2008) · Applied Physics Letters · doi:10.1063/1.3036898 · Cited by 100 · cited 1×
“The separation of red and white blood cells from whole blood [56,57,58], and living cells loaded with magnetic nanoparticles [59] have been achieved.”
Miró, M., & Hansen, E. H. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.02.035 · Cited by 100 · cited 1×
“The features of compactness, portability, sensitivity and parallelization make LOC devices beneficial for various applications, including point-of-care (POC) diagnostics [7, 8], drug delivery [9, 10], molecule and material synthesis [11], chemical reaction control and detection [2, 12], cellular process studies [5, 13…”
Fabrication of a dielectrophoretic chip with 3D silicon electrodes
Iliescu, C., Xu, G. L., Samper, V., et al. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/3/009 · Cited by 98 · cited 3×
“The details of fabricating a dielectric chip with 3D silicon chip can refer to the work by Iliescu et al [74], where the fabrication process involves anodic bonding, deep reactive ion etching (DRIE), wet etching and thin-film deposition.”
Gallo‐Villanueva, R. C., López, C. E. R., Díaz‐de‐la‐Garza, R. I., Reyes‐Betanzo, C., & Lapizco‐Encinas, B. H. (2009) · Electrophoresis · doi:10.1002/elps.200900355 · Cited by 98 · cited 9×
“15, interdigitated electrodes have been used to separate live and dead cells (i.e. Listeria innocua [112] and yeast cells [113]), and nano-/micro-particles [89,114], capture DNA [115], bacteria [36], polystyrene beads [114,116] and blood erythrocytes [114], capture and release ribosomal RNA (rRNA) [117], separate huma…”
MethodInfluentialLewpiriyawong, N., Yang, C., & Lam, Y. C. (2008) · Biomicrofluidics · doi:10.1063/1.2973661 · Cited by 95
An efficient cell separation system using 3D-asymmetric microelectrodes
Park, J., Kim, B., Choi, S. K., Hong, S. H., Lee, S. H., & Lee, K.-I. (2005) · Lab on a Chip · doi:10.1039/b506803g · Cited by 90 · cited 1×
“Asymmetric microelectrode arrays which induce continuously varied electric fields along the transverse direction of a channel have been developed by Park et al [162], and have demonstrated their capability by sorting mouse P19 embryonic carcinoma (EC) and red blood cells (RBCs).”
Lab-on-a-chip technologies for massive parallel data generation in the life sciences: A review
Trietsch, S. J., Hankemeier, T., & van der Linden, H. J. (2011) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2011.03.005 · Cited by 88
Biochip for separating fetal cells from maternal circulation
Mohamed, H., Turner, J. N., & Caggana, M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.06.025 · Cited by 83 · cited 1×
“weir [34], pillar [35], and through-holes [36]) within the microchannels.”
Tay, F. E. H., Yu, L., Pang, A. J., & Iliescu, C. (2007) · Electrochimica Acta · doi:10.1016/j.electacta.2006.09.022 · Cited by 81 · cited 1×
“This 3D silicon electrode structure exhibits constant DEP forces along the height of the microfluidic channel, and achieves high trapping efficiency and high-throughput manipulation performance, which has been utilized to trap yeast cells [173], and separate live and dead yeast cells [167,174].”
High-Throughput Positive-Dielectrophoretic Bioparticle Microconcentrator
Gadish, N., & Voldman, J. (2006) · Analytical Chemistry · doi:10.1021/ac061170i · Cited by 80 · cited 7×
“The details of fabricating extruded gold electrodes from the bottom substrates can be found in the work of Voldman et al [72].”
InfluentialSuehiro, J., Shutou, M., Hatano, T., et al. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(03)00517-3 · Cited by 80 · cited 1×
“Suehiro et al [123,124] proposed a method for detecting biological cells and bacteria called dielectrophoretic impedance measurement (DEPIM), which utilizes the positive DEP force to capture biological particles in suspension onto an interdigitated microelectrode array, and the transient variation of the electrical im…”
Particle electrophoresis and dielectrophoresis in curved microchannels
Zhu, J., & Xuan, X. S. (2009) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2009.08.031 · Cited by 79 · cited 1×
“27c) to focus particles [223], and separate particles based on size [218] and charge [224].”
Krishnan, R., Sullivan, B. D., Mifflin, R. L., Esener, S. C., & Heller, M. J. (2008) · Electrophoresis · doi:10.1002/elps.200800037 · Cited by 79 · cited 1×
“Using an array (or matrix) of circular electrodes coated with porous hydrogel layers, Krishnan et al [146] separated polystyrene particles and DNAderivatized nanoparticles under high-conductive conditions.”
Performance characterization of an insulator‐based dielectrophoretic microdevice
Ozuna‐Chacón, S., Lapizco‐Encinas, B. H., Rito‐Palomares, M., et al. (2008) · Electrophoresis · doi:10.1002/elps.200700865 · Cited by 78 · cited 1×
“suspending medium can affect the performance [196].”
Sergent‐Tanguy, S., Chagneau, C., Neveu, I., & Naveilhan, P. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00210-3 · Cited by 71 · cited 1×
“Fluorescence-activated cell sorting (FACS) [21,22,23] and magnetic-activated cell sorting (MACS) [24,25,26] utilize fluorophore-conjugated antibodies and magnetic beads conjugated with antibodies to label cell of interests, respectively.”
Çetin, B., Kang, Y., Wu, Z., et al. (2009) · Electrophoresis · doi:10.1002/elps.200800464 · Cited by 71 · cited 1×
“Cetin et al [181] utilized two asymmetric copper electrodes embedded along the sidewalls for an electric field gradient, and then separated latex particles based on size and also separated yeast cells and white blood cells (WBCs).”
Dielectrophoretic manipulation and separation of microparticles using curved microelectrodes
Khoshmanesh, K., Zhang, C., Tovar-Lopez, F. J., et al. (2009) · Electrophoresis · doi:10.1002/elps.200900079 · Cited by 70 · cited 1×
“Based on this design, manipulation and separation of two-sized polystyrene particles [137], and the tunable multiplex separation of polystyrene particles at different frequencies [135] were demonstrated.”
Conclusions and Future Perspectives
Fanelli, R. (2011) · Wiley eBooks · doi:10.1002/9781118000816.ch19 · Cited by 70
Negative Dielectrophoretic Patterning with Colloidal Particles and Encapsulation into a Hydrogel
Suzuki, M., Yasukawa, T., Shiku, H., et al. (2007) · Langmuir · doi:10.1021/la063075a · Cited by 67 · cited 1×
“lambia [119], and pattern colloid particles [120].”
Flow sandwich-type immunoassay in microfluidic devices based on negative dielectrophoresis
Yasukawa, T., Suzuki, M., Sekiya, T., et al. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.11.010 · Cited by 67 · cited 2×
“Yasukawa et al [110] optimized the design to rectangular features with different widths and gaps, and the manipulation and separation of microparticles depending on size has been demonstrated.”
A 3D paired microelectrode array for accumulation and separation of microparticles
Chen, D. F., Du, H., & Li, W. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/7/008 · Cited by 64 · cited 2×
“18) [67,68,70,71], which have been demonstrated for the manipulation, accumulation and separation of micro- and nanoparticles based on size.”
Self-citationBidirectional field-flow particle separation method in a dielectrophoretic chip with 3D electrodes
Iliescu, C., Yu, L., Tay, F. E. H., et al. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.11.023 · Cited by 63 · cited 2×
“This 3D silicon electrode structure exhibits constant DEP forces along the height of the microfluidic channel, and achieves high trapping efficiency and high-throughput manipulation performance, which has been utilized to trap yeast cells [173], and separate live and dead yeast cells [167,174].”
Insulator‐based dielectrophoretic separation of small particles in a sawtooth channel
Chen, K. P., Pacheco, J. R., Hayes, M. A., et al. (2009) · Electrophoresis · doi:10.1002/elps.200800833 · Cited by 62 · cited 2×
“Chen et al [215] studied the particle movement in a nonconverging sawtooth channel, and the results indicated that particles can be selectively trapped by varying the channel geometry. focusing behavior of 15 m particles by comparing the stream width at inlet (middle) and outlet (bottom) [217].”
Salmanzadeh, A., Kittur, H., Sano, M. B., et al. (2012) · Biomicrofluidics · doi:10.1063/1.3699973 · Cited by 59 · cited 1×
“Moreover, this technique was utilized to selectively concentrate human breast cancer cells [229], isolate human leukemia cells from erythrocytes[230], separate tumor initiating cells (TICs) from non-TICs [231], and mouse ovarian surface epithelial (MOSE) cells from fibroblasts and macrophages [232], and characterize t…”
Automatic microfluidic platform for cell separation and nucleus collection
Tai, C.-H., Hsiung, S.-K., Chen, C.-Y., Tsai, M., & Lee, G. (2007) · Biomedical microdevices · doi:10.1007/s10544-007-9061-7 · Cited by 59 · cited 1×
“By integrating the electrode array with a serpentine micropump and pneumatic microvalves, viable and non-viable cells were separated and collected, and nucleus was collected after cell lysis [107].”
Lab-on-a-chip technologies for single-molecule studies
Zhao, Y., Chen, D., Yue, H., French, J. B., Rufo, J., Benkovic, S. J., & Huang, T. J. (2013) · Lab on a Chip · doi:10.1039/c3lc90042h · Cited by 58 · cited 1×
“The features of compactness, portability, sensitivity and parallelization make LOC devices beneficial for various applications, including point-of-care (POC) diagnostics [7, 8], drug delivery [9, 10], molecule and material synthesis [11], chemical reaction control and detection [2, 12], cellular process studies [5, 13…”
Dielectrophoretic separation of carbon nanotubes and polystyrene microparticles
Zhang, C., Khoshmanesh, K., Tovar-Lopez, F. J., Mitchell, A., Włodarski, W., & Kalantar‐Zadeh, K. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0419-4 · Cited by 58 · cited 2×
“Zhang et al [225] developed a circular channel to generate field gradients towards the circle centre, particles experiencing different DEP responses will be directed to different locations along the channel width direction, and thus be separated into different outlets.”
Dielectrophoretic oocyte selection chip for in vitro fertilization
Choi, W., Kim, J.-S., Lee, D., et al. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9141-8 · Cited by 56 · cited 2×
“Choi et al [106] used this design to separate porcine oocytes based on the difference of”
MethodDielectrophoretic-activated cell sorter based on curved microelectrodes
Khoshmanesh, K., Zhang, C., Tovar-Lopez, F. J., Nahavandi, S., Baratchi, S., Mitchell, A., & Kalantar‐Zadeh, K. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0558-7 · Cited by 56 · cited 1×
“By combining two sets of curved electrode arrays, the separation of live and dead yeast cells at different conductivities of suspending medium has been achieved, along with assessing the sorting performance on the downstream boomerang-shaped electrodes [138].”
Parikesit, G. O. F., Markesteijn, A. P., Piciu, O. M., et al. (2008) · Biomicrofluidics · doi:10.1063/1.2930817 · Cited by 54
Han, K.-H., Han, S., & Frazier, A. B. (2009) · Lab on a Chip · doi:10.1039/b909753h · Cited by 54 · cited 2×
“Han et al [136] developed a piecewise curved electrode array placed at an angle to the direction of the flow to separate polystyrene particle according to size.”
Diamagnetic capture mode magnetophoretic microseparator for blood cells
Han, K.-H., & Frazier, A. B. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859097 · Cited by 54
Alternating Current Electrokinetic Motion of Colloidal Particles on Interdigitated Microelectrodes
Park, S., & Beşkök, A. (2008) · Analytical Chemistry · doi:10.1021/ac7024859 · Cited by 53 · cited 2×
“Park and Beskok [121] proposed a theoretical model to predict the AC electrokinetic motion of microparticles, which were validated by parametric experiments of colloid particles, including polystyrene and gold particles, and C. sporogenes bacterial spores, with interdigitated electrodes.”
Dielectrophoretic separation of mouse melanoma clones
Sabuncu, A. C., Liu, J. A., Beebe, S. J., & Beşkök, A. (2010) · Biomicrofluidics · doi:10.1063/1.3447702 · Cited by 53 · cited 1×
“Other research work on trapping cells and silica beads [98], concentrating embryonic stem cells (ESCs) [99], sorting nano-[100] and micro-particles [101], clones of mouse melanoma B16F10 cells [102], separating cancel cells from blood [103,104], separating dormant Mycobacterium smegmatis from live and dead M.”
Blood cell capture in a sawtooth dielectrophoretic microchannel
Jones, P. V., Staton, S. J. R., & Hayes, M. A. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5284-9 · Cited by 52 · cited 1×
“epidermidis) [213] and capture blood cells [214], which generates a series of gradually stronger field gradient along the length of the channnel.”
A novel method to construct 3D electrodes at the sidewall of microfluidic channel
Li, S., Li, M., Hui, S. Y. R., et al. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-1068-6 · Cited by 51 · cited 1×
“Figure 8 Fabrication process flow for a microfluidic chip with alloy microsphere electrodes embedded at the sidewall of the microchannel: (a) fabrication of SU-8 mold, (b) patterning of planar electrodes, (c) fabrication of microchannel, (d) bonding, and (e) thermal post-treatment [77].”
Self-citationA dielectrophoretic barrier-based microsystem for separation of microparticles
Chen, D., & Du, H. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0151-x · Cited by 50 · cited 2×
“18) [67,68,70,71], which have been demonstrated for the manipulation, accumulation and separation of micro- and nanoparticles based on size.”
Negative dielectrophoretic capture of bacterial spores in food matrices
Köklü, M., Park, S., Pillai, S. D., et al. (2010) · Biomicrofluidics · doi:10.1063/1.3479998 · Cited by 49 · cited 1×
“sporogenes spores from high conductivity media was achieved by Koklu et al using negative DEP [144].”
MethodIntegrated electrical concentration and lysis of cells in a microfluidic chip
Church, C., Zhu, J., Huang, G., Tzeng, T.-R. J., & Xuan, X. S. (2010) · Biomicrofluidics · doi:10.1063/1.3496358 · Cited by 48 · cited 1×
“25b), concentration and lysis of red blood cells, and separation of leukaemia cells from red blood cells [204].”
Microdevices for separation, accumulation, and analysis of biological micro- and nanoparticles
Kentsch, J., Dürr, M., Schnelle, T., et al. (2003) · IEE Proceedings - Nanobiotechnology · doi:10.1049/ip-nbt:20031127 · Cited by 47 · cited 1×
“Slanted electrode arrays have been patterned on both the top and bottom surfaces of the microchannel (figure 18) [78, 79, 81, 82], which have been demonstrated for the manipulation, accumulation and separation of microand nanoparticles based on size.”
Li, M., Li, S., Li, W., Wen, W., & Alıcı, G. (2013) · Electrophoresis · doi:10.1002/elps.201200546 · Cited by 46
Self-citationChen, D., & Du, H. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0545-z · Cited by 46 · cited 2×
“A series of circular microchannels [87] were utilized for particle concentration, which could focus the externally applied electric field stepwise: the field upstream is relatively lower and the electrokinetic effect responsible for continuously transporting particles is dominant, while the field downstream is higher…”
Sequential Field-Flow Cell Separation Method in a Dielectrophoretic Chip With 3-D Electrodes
Yu, L., Iliescu, C., Xu, G., et al. (2007) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2007.901136 · Cited by 46 · cited 1×
“This 3D silicon electrode structure exhibits constant DEP forces along the height of the microfluidic channel, and achieves high trapping efficiency and high-throughput manipulation performance, which has been utilized to trap yeast cells [173], and separate live and dead yeast cells [167,174].”
Tuning direct current streaming dielectrophoresis of proteins
Nakano, A., Camacho‐Alanis, F., Chao, T., et al. (2012) · Biomicrofluidics · doi:10.1063/1.4742695 · Cited by 45 · cited 1×
“24) were embedded in the microchannels to manipulate a variety of particles, such as DNA [188,189,190], protein [191,192], virus [193], live and dead bacteria [187,194].”
Continuous particle focusing in a waved microchannel using negative dc dielectrophoresis
Li, M., Li, S., Cao, W., et al. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/9/095001 · Cited by 45 · cited 2×
“(b) Schematic of particle focusing principle in a waved microchannel (top) and experimental images showing the focusing behavior of 15 m particles by comparing the stream width at inlet (middle) and outlet (bottom) [217].”
Self-citationDielectrophoretic separation of biological samples in a 3D filtering chip
Iliescu, C., Xu, G. L., Ong, P. L., et al. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/7/s10 · Cited by 45 · cited 2×
“The details of fabricating a dielectric chip with 3D silicon chip can refer to the work by Iliescu et al [74], where the fabrication process involves anodic bonding, deep reactive ion etching (DRIE), wet etching and thin-film deposition.”
Li, M., Li, S., Cao, W., et al. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-1071-y · Cited by 44 · cited 1×
“Li et al [160] proposed an integrated array consisting of three units: a funnel-shaped focusing unit, a straight aligning unit, and a crescent-shaped trapping unit, which was used to concentrate different-sized polystyrene”
Self-citationDielectrophoretic manipulation of ribosomal RNA
Giraud, G., Pethig, R., Schulze, H., Henihan, G., Terry, J. G., Menachery, A., Ciani, I., Corrigan, D. K., Campbell, C. J., Mount, A. R., et al. (2011) · Biomicrofluidics · doi:10.1063/1.3604395 · Cited by 44 · cited 1×
“Listeria innocua [112] and yeast cells [113]), and nano-/micro-particles [89,114], capture DNA [115], bacteria [36], polystyrene beads [114,116] and blood erythrocytes [114], capture and release ribosomal RNA (rRNA) [117], separate human colon cancer cells (HT-29 cells) from RBCs [118], characterize and separate C.”
Lewpiriyawong, N., & Yang, C. (2012) · Biomicrofluidics · doi:10.1063/1.3682049 · Cited by 42 · cited 1×
“21), and separated submicron and micron particles by size [80,179], yeast cells and E.”
Li, S., Li, M., Bougot-Robin, K., et al. (2013) · Biomicrofluidics · doi:10.1063/1.4795856 · Cited by 41 · cited 1×
“Li et al [161] proposed using parallel multiple electrode arrays arranged in a radial direction for high-throughput performance, and captured polystyrene particle, yeast cells, and E-coli, and also separated live and yeast cells.”
Self-citationSize based separation of microparticles using a dielectrophoretic activated system
Khoshmanesh, K., Zhang, C., Nahavandi, S., et al. (2010) · Journal of Applied Physics · doi:10.1063/1.3457226 · Cited by 40 · cited 2×
“Based on this design, manipulation and separation of two-sized polystyrene particles [137], and the tunable multiplex separation of polystyrene particles at different frequencies [135] were demonstrated.”
Addressable micropost array for the dielectrophoretic manipulation of particles in fluid
Hunt, T. P., Lee, H. Y., & Westervelt, R. M. (2004) · Applied Physics Letters · doi:10.1063/1.1840109 · Cited by 39 · cited 1×
“Hunt et al [168] utilized an array of post-shaped gold electrodes to trap and manipulate a single polystyrene particle using positive and negative DEP, respectively.”
Centrifugal Separations in Biotechnology
(2007) · Elsevier eBooks · doi:10.1016/b978-1-85617-477-0.x5000-9 · Cited by 38 · cited 1×
“Moreover, centrifugation is a common technique to separate particles in bulk based on their differences in size and density [27], but this manual, macroscale, multistep technique needs laboratories dedicated to these functions and may introduce contamination during the process [28].”
Jen, C., & Chang, H.-H. (2011) · Biomicrofluidics · doi:10.1063/1.3609263 · Cited by 38 · cited 1×
“Circular microelectrode pairs were proposed by Jen and Chang [141] to generate a stepping electric field, and the concentration of HeLa cells was accomplished.”
Suscillon, C., Velev, O. D., & Slaveykova, V. I. (2013) · Biomicrofluidics · doi:10.1063/1.4801870 · Cited by 32 · cited 1×
“reinhardtii in fresh waters [157], and detect and actuate single Chinese hamster ovary (CHO) cells [158].”
Chung, C.-C., Cheng, I.-F., Yang, W., et al. (2011) · Biomicrofluidics · doi:10.1063/1.3600650 · Cited by 31 · cited 1×
“coli were characterized using similar quadruple electrode [94].”
MethodCell electrophoresis — a method for cell separation and research into cell surface properties
Korohoda, W., & Wilk, A. M. (2008) · Cellular & Molecular Biology Letters · doi:10.2478/s11658-008-0004-y · Cited by 31 · cited 1×
“Several studies have demonstrated the biological applications of EP, and were reviewed by Korohoda and Wilk [60].”
Çetin, B., & Li, D. (2010) · Electrophoresis · doi:10.1002/elps.201000107 · Cited by 30 · cited 2×
“Cetin and Li [176] manipulated particles with different DEP responses and separated white blood cells (WBCs) from 10 um latex particles.”
Centrifugal Separations in Biotechnology
(2020) · Elsevier eBooks · doi:10.1016/c2017-0-03265-2 · Cited by 28
Strategies for dielectrophoretic separation in laboratory-on-a-chip systems
Hughes, M. (2002) · Open Research (University of Surrey) · doi:10.1002/1522-2683(200208)23:16<2569::aid-elps2569>3.0.co;2-m · Cited by 28
Ino, K., Shiku, H., Ozawa, F., et al. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22445 · Cited by 26 · cited 1×
“smegmatis [153], multilayered array and grid (MLAG) electrodes [154] composed of two metal layers and a sandwiched dielectric layer were employed to trap and pattern polystyrene particles using negative DEP, ring-dot-shaped electrodes were developed by Taff and Voldman [155] to trap and sort silver-coated beads and He…”
Huang, C., Weng, C., & Jen, C. (2011) · Biomicrofluidics · doi:10.1063/1.3646757 · Cited by 26 · cited 2×
“Jen et al [208,209,210,211] utilized X-patterned insulating structures in the microchannel to squeeze the electric fields, which could generate a high field gradient at the constricted regions, when AC fields are applied via planer microelectrodes placed at the sides of the microchannel.”
Particle trapping using dielectrophoretically patterned carbon nanotubes
Khoshmanesh, K., Zhang, C., Nahavandi, S., Tovar-Lopez, F. J., Baratchi, S., Hu, Z., Mitchell, A., & Kalantar‐Zadeh, K. (2010) · Electrophoresis · doi:10.1002/elps.200900717 · Cited by 26 · cited 1×
“The authors also reported the patterning of multi-walled carbon nanotubes (MWCNTs) between curved microelectrodes to trap polystyrene particles with different surface modifications [139], and sort particles of different sizes [140].”
Hydrodynamic separation of cells utilizing insulator-based dielectrophoresis
Jen, C., Huang, C., & Shih, H.-Y. (2009) · Microsystem Technologies · doi:10.1007/s00542-009-0947-6 · Cited by 25 · cited 2×
“Jen et al [208,209,210,211] utilized X-patterned insulating structures in the microchannel to squeeze the electric fields, which could generate a high field gradient at the constricted regions, when AC fields are applied via planer microelectrodes placed at the sides of the microchannel.”
Beck, J. D., Shang, L., Li, B., Marcus, M. S., & Hamers, R. J. (2008) · Analytical Chemistry · doi:10.1021/ac702113t · Cited by 24 · cited 1×
“The patterning and collection of mammalian virus (HSV-1) by both positive and negative DEP at different frequencies was accomplished by Hughes et al [95] as well as the trapping of protein molecules [96] and bacterial spores [97] have been achieved in a triangular polynomial electrode.”
Formation of embryoid bodies using dielectrophoresis
Agarwal, S., Sebastian, A., Forrester, L. M., & Markx, G. H. (2012) · Biomicrofluidics · doi:10.1063/1.3699969 · Cited by 21 · cited 1×
“Other research work on trapping cells and silica beads [98], concentrating embryonic stem cells (ESCs) [99], sorting nano-[100] and micro-particles [101], clones of mouse melanoma B16F10 cells [102], separating cancel cells from blood [103,104], separating dormant Mycobacterium smegmatis from live and dead M.”
Ducrée, J. (2009) · Procedia Chemistry · doi:10.1016/j.proche.2009.07.129 · Cited by 9 · cited 1×
“The features of compactness, portability, sensitivity and parallelization make LOC devices beneficial for various applications, including point-of-care (POC) diagnostics [7, 8], drug delivery [9, 10], molecule and material synthesis [11], chemical reaction control and detection [2, 12], cellular process studies [5, 13…”
Dielectrophoretically patterned carbon nanotubes to sort microparticles
Khoshmanesh, K., Zhang, C., Nahavandi, S., Baratchi, S., Mitchell, A., & Kalantar‐Zadeh, K. (2010) · Electrophoresis · doi:10.1002/elps.201000104 · Cited by 8 · cited 1×
“The authors also reported the patterning of multi-walled carbon nanotubes (MWCNTs) between curved microelectrodes to trap polystyrene particles with different surface modifications [139], and sort particles of different sizes [140].”
Cited by
Particle manipulations in non-Newtonian microfluidics: A review
Lu, X., Liu, C., Hu, G., & Xuan, X. (2017) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2017.04.019 · Cited by 289
Arzt, E., Quan, H., McMeeking, R. M., & Hensel, R. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2021.100823 · Cited by 253
Raman image-activated cell sorting
Nitta, N., Iino, T., Isozaki, A., Yamagishi, M., Kitahama, Y., Sakuma, S., Suzuki, Y., Tezuka, H., Oikawa, M., Arai, F., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17285-3 · Cited by 205
Enrichment and single-cell analysis of circulating tumor cells
Song, Y., Tian, T., Shi, Y., Liu, W., Zou, Y., Khajvand, T., Wang, S., Zhu, Z., & Yang, C. (2017) · Chemical Science · doi:10.1039/c6sc04671a · Cited by 167
Microfluidic Sample Preparation for Single Cell Analysis
Hosic, S., Murthy, S. K., & Koppes, A. N. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04077 · Cited by 166
Metadata
- Authors
- Li, M., Li, W. H., Zhang, J., Alici, G., & Wen, W.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2014-01-08
- Volume
- 47
- Issue
- 6
- Pages
- 063001
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2009910733
- Cited by
- 223
- References
- 179
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.