Improved accuracy of the NPL-CsF2 primary frequency standard: evaluation of distributed cavity phase and microwave lensing frequency shifts
Open accessThe DOI matches its Crossref record.
Abstract
We evaluate the distributed cavity phase and microwave lensing frequency shifts, which were the two largest sources of uncertainty for the NPL-CsF2 cesium fountain clock. We report measurements that confirm a detailed theoretical model of the microwave cavity fields and the frequency shifts of the clock that they produce. The model and measurements significantly reduce the distributed cavity phase uncertainty to $1.1 \times 10^{-16}$. We derive the microwave lensing frequency shift for a cylindrical cavity with circular apertures. An analytic result with reasonable approximations is given, in addition to a full calculation that indicates a shift of $6.2 \times 10^{-17}$. The measurements and theoretical models we report, along with improved evaluations of collisional and microwave leakage induced frequency shifts, reduce the frequency uncertainty of the NPL-CsF2 standard to $2.3 \times 10^{-16}$, nearly a factor of two lower than its most recent complete evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 15
- Wynands R, 2005, Metrologia, 42, S64, 10.1088/0026-1394/42/3/S08 · DOI · Paper page
- Szymaniec K, 2005, Metrologia, 42, 49, 10.1088/0026-1394/42/1/007 · DOI · Paper page
- 10.1109/TIM.2005.843572 · doi:10.1109/tim.2005.843572
- 10.1103/PhysRevLett.98.153002 · DOI
- Szymaniec K, 2010, Metrologia, 47, 363, 10.1088/0026-1394/47/4/003 · DOI
- Li R, 2004, Metrologia, 41, 376, 10.1088/0026-1394/41/6/004 · DOI · Paper page
- Li R, 2010, Metrologia, 47, 534, 10.1088/0026-1394/47/5/004 · DOI
- 10.1103/PhysRevLett.106.130801 · DOI · Paper page
- Weyers S Schroeder R Wynands R, 2006, Proc. 20th European Frequency and Time Forum, 173
- 10.1109/TUFFC.2006.1678186 · DOI
- 10.1109/TUFFC.2007.455 · doi:10.1109/tuffc.2007.455
- Chapelet F Bize S Wolf P Santarelli G Rosenbusch P Tobar M E Laurent P Salomon C Clairon A, 2006, Proc. 20th European Frequency and Time Forum, 160
- 10.1109/TIM.2010.2088430 · DOI
- 10.1103/PhysRevLett.97.073002 · DOI
- 10.1007/s00340-007-2813-5 · DOI
Cited by
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationProgress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Self-citationFirst accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Ultra-stable long distance optical frequency distribution using the Internet fiber network
Lopez, O., Haboucha, A., Chanteau, B., Chardonnet, C., Amy-Klein, A., & Santarelli, G. (2012) · Optics Express · doi:10.1364/oe.20.023518 · Cited by 175
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Metadata
- Authors
- Li, R., Gibble, K., & Szymaniec, K.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2011-08-26
- Volume
- 48
- Issue
- 5
- Pages
- 283-289
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2019389329
- Cited by
- 138
- References
- 0
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved accuracy of the NPL-CsF2 primary frequency standard: evaluation of distributed cavity phase and microwave lensing frequency shifts. https://app.cochat.ai/papers/10.1088/0026-1394/48/5/007
- The paper
- Li, R., Gibble, K., & Szymaniec, K. (2011). Improved accuracy of the NPL-CsF2 primary frequency standard: evaluation of distributed cavity phase and microwave lensing frequency shifts. Metrologia. https://doi.org/10.1088/0026-1394/48/5/007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.