Evaluating the performance of the NPL femtosecond frequency combs: agreement at the 10−21level
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Abstract Results are presented from a series of comparisons between two independent femtosecond frequency comb systems at NPL, which were carried out in order to assess their systematic uncertainty. Simultaneous measurements with the two systems demonstrate agreement at the level of 5 × 10 −18 when measuring an optical frequency against a common microwave reference. When simultaneously measuring the ratio of two optical frequencies, agreement at the 3 × 10 −21 level is observed. The results represent the highest reported level of agreement to date between Ti:Sapphire and Er-doped femtosecond combs. The limitations of the combs when operating in these two different manners are discussed, including traceability to the SI second, which can be achieved with an uncertainty below 1 × 10 −16 . The technical details presented underpin recent absolute frequency measurements of the 88 Sr + and 171 Yb + optical clock transitions at NPL, as well as a frequency ratio measurement between the two optical clock transitions in 171 Yb + .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661 · cited 1×
“light entering the first PCF are adjusted to generate a spectrum which is peaked at 532 nm and 1064 nm for subsequent detection of the carrierenvelope offset (CEO) frequency f 0 using the f −2f scheme [18]. Fundamental comb lines at 1064 nm are frequency-doubled to 532 nm in a periodically poled KTiOPO 4 crystal and het…”
MethodFrequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 1×
“These optical clocks are opening up several interesting areas of research including improved tests of fundamental physics [1] and clock-based geodesy [2] and it is expected that a redefinition of the second in terms of an optical clock transition frequency will take place in the future.”
BackgroundAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationMaking optical atomic clocks more stable with 10−16-level laser stabilization
Jiang, Y. Y., Ludlow, A. D., Lemke, N. D., Fox, R. W., Sherman, J. A., Ma, L.-S., & Oates, C. W. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.313 · Cited by 462 · cited 1×
“ection sections of the two combs are orthogonal to one another. There is currently ongoing development around the globeofnext-generationlaserLOswith instabilities below 1 × 10−16 at short time scales [29, 30, 31, 32, 33], which promise associated improvements in the short-term instability of optical clocks. However, s…”
BackgroundOptical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2004) · Science · doi:10.1126/science.1095092 · Cited by 319 · cited 2×
“PL-FC3 is used. 2.3. Stabilisation Many previous two-comb comparisons have involved tight phase locking of a single comb mode (and hence all comb modes) to an ultra-stable laser local oscillator (LO) [11, 9, 12]. In this work the comb modes are only loosely locked to a microwave LO and the transfer oscillator scheme o…”
BackgroundMethodInfluentialFirst accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Uncertainty of a frequency comparison with distributed dead time and measurement interval offset
Yu, D.-H., Weiss, M., & Parker, T. E. (2007) · Metrologia · doi:10.1088/0026-1394/44/1/014 · Cited by 44
Cited by
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Self-citationTest of Special Relativity Using a Fiber Network of Optical Clocks
Delva, P., Lodewyck, J., Bilicki, S., Bookjans, E., Vallet, G., Le Targat, R., Pottie, P.-E., Guerlin, C., Meynadier, F., Le Poncin-Lafitte, C., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.221102 · Cited by 227
Self-citationIntercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64
End-to-end topology for fiber comb based optical frequency transfer at the 10 −21 level
Benkler, E., Lipphardt, B., Puppe, T., Wilk, R., Rohde, F., & Sterr, U. (2019) · Optics Express · doi:10.1364/oe.27.036886 · Cited by 51
“The broadband comb either originates from a single branch of the comb generation system [22–26] or is generated in two distinct branches which are actively stabilized to each other [27].”
BackgroundReal-time phase tracking for wide-band optical frequency measurements at the 20th decimal place
Giunta, M., Hänsel, W., Fischer, M., Lezius, M., Udem, T., & Holzwarth, R. (2020) · Nature Photonics · doi:10.1038/s41566-019-0520-5 · Cited by 41
Metadata
- Authors
- Johnson, L. A. M., Gill, P., & Margolis, H. S.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2015-01-08
- Volume
- 52
- Issue
- 1
- Pages
- 62-71
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2055074816
- Cited by
- 39
- References
- 8
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluating the performance of the NPL femtosecond frequency combs: agreement at the 10−21level. https://app.cochat.ai/papers/10.1088/0026-1394/52/1/62
- The paper
- Johnson, L. A. M., Gill, P., & Margolis, H. S. (2015). Evaluating the performance of the NPL femtosecond frequency combs: agreement at the 10−21level. Metrologia. https://doi.org/10.1088/0026-1394/52/1/62
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.