A Monte Carlo investigation of optical pathlength in inhomogeneous tissue and its application to near-infrared spectroscopy
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
In order to quantify near-infrared spectroscopic (NIRS) data on an inhomogeneous medium, knowledge of the contribution of the various parts of the medium to the total NIRS signal is required. This is particularly true in the monitoring of cerebral oxygenation by NIRS, where the contribution of the overlying tissues must be known. The concept of the time point spread function (TPSF), which is used extensively in NIRS to determine the effective optical pathlength, is expanded to the more general inhomogeneous case. This is achieved through the introduction of the partial differential pathlength, which is the effective optical pathlength in the inhomogeneous medium, and an analytical proof of the applicability of the modified Beer-Lambert law in an inhomogeneous medium is shown. To demonstrate the use of partial differential pathlength, a Monte Carlo simulation of a two-concentric-sphere medium representing a simplified structure of the head is presented, and the possible contribution of the overlying medium to the total NIRS signal is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Self-citationPatterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Wyatt, J. S., Delpy, D. T., Cope, M., Wray, S., & Reynolds, E. O. R. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90467-8 · Cited by 876
Self-citationA Monte Carlo model for the absorption and flux distributions of light in tissue
Wilson, B. C., & Adam, G. (1983) · Medical Physics · doi:10.1118/1.595361 · Cited by 690
A finite element approach for modeling photon transport in tissue
Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993) · Medical Physics · doi:10.1118/1.597069 · Cited by 635
Self-citationArridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Self-citationMethods of Quantitating Cerebral Near Infrared Spectroscopy Data
Cope, M., Delpy, D. T., Reynolds, E. O. R., Wray, S., Wyatt, J., & van der Zee, P. (1988) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-9510-6_21 · Cited by 502
Self-citationFlock, S. T., Patterson, M. S., Wilson, B. C., & Wyman, D. R. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1989.1173624 · Cited by 489
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
“By using diffusion approximations and finite-element or Monte-Carlobased computational methods [12,13,16,73–76], we can estimate the sensitivity profile for each source–detector pair on the basis of the optical properties of the tissue as shown in Fig 1(a).”
BackgroundMethodFang, Q., & Boas, D. A. (2009) · Optics Express · doi:10.1364/oe.17.020178 · Cited by 1,003
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
The modified Beer–Lambert law revisited
Kocsis, L., Herman, P., & Eke, A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/5/n02 · Cited by 679
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Quantification in tissue near–infrared spectroscopy
Delpy, D. T., & Cope, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0046 · Cited by 507
Self-citationBest practices for fNIRS publications
Yücel, M. A., Lühmann, A. V., Scholkmann, F., Gervain, J., Dan, I., Ayaz, H., Boas, D., Cooper, R. J., Culver, J., Elwell, C. E., et al. (2021) · Neurophotonics · doi:10.1117/1.nph.8.1.012101 · Cited by 492
Okada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Self-citationDuncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Fallon, P., Tyszczuk, L., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199605000-00025 · Cited by 469
Self-citationScholkmann, F., & Wolf, M. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.10.105004 · Cited by 450
Takahashi, T., Takikawa, Y., Kawagoe, R., Shibuya, S., Iwano, T., & Kitazawa, S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.012 · Cited by 396
Mesh-based Monte Carlo method using fast ray-tracing in Plücker coordinates
Fang, Q. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000165 · Cited by 384
Chen, W.-L., Wagner, J., Heugel, N., Sugar, J., Lee, Y.-W., Conant, L., Malloy, M., Heffernan, J., Quirk, B., Zinos, A., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00724 · Cited by 382
Okada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002915 · Cited by 364
Self-citationNear-infrared spectroscopy: A report from the McDonnell infant methodology consortium
Gervain, J., Mehler, J., Werker, J. F., Nelson, C. A., Csibra, G., Lloyd-Fox, S., Shukla, M., & Aslin, R. N. (2011) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2010.07.004 · Cited by 363
Comment on the modified Beer–Lambert law for scattering media
Sassaroli, A., & Fantini, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/n07 · Cited by 352
“The values of the DPF under various conditions have been studied both experimentally (Duncan et al 1995, Kohl et al 1998) and numerically ( Hiraoka et al 1993 ) in order to apply equation (5) to different kinds of biological tissues.”
BackgroundMethodNon-invasive NIR spectroscopy of human brain function during exercise
Perrey, S. (2008) · Methods · doi:10.1016/j.ymeth.2008.04.005 · Cited by 346
Near‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
Human Identification Using Palm-Vein Images
Zhou, Y., & Kumar, A. (2011) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2011.2158423 · Cited by 290
Fukui, Y., Ajichi, Y., & Okada, E. (2003) · Applied Optics · doi:10.1364/ao.42.002881 · Cited by 286
Modified Beer-Lambert law for blood flow
Baker, W. B., Parthasarathy, A. B., Busch, D. R., Mesquita, R. C., Greenberg, J. H., & Yodh, A. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004053 · Cited by 283
Jasdzewski, G., Strangman, G., Wagner, J., Kwong, K. K., Poldrack, R. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00311-2 · Cited by 277
Okada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002906 · Cited by 274
Self-citationBeer–Lambert law for optical tissue diagnostics: current state of the art and the main limitations
Oshina, I., & Spigulis, J. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.10.100901 · Cited by 273
Direct characterization and removal of interfering absorption trends in two-layer turbid media
Saager, R. B., & Berger, A. J. (2005) · Journal of the Optical Society of America A · doi:10.1364/josaa.22.001874 · Cited by 271
Strangman, G. E., Li, Z., & Zhang, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066319 · Cited by 262
Determining changes in NIR absorption using a layered model of the human head
Steinbrink, J., Wabnitz, H., Obrig, H., Villringer, A., & Rinneberg, H. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/320 · Cited by 259
A new look at the essence of the imaging photoplethysmography
Kamshilin, A. A., Nippolainen, E., Sidorov, I. S., Vasilev, P. V., Erofeev, N. P., Podolian, N. P., & Romashko, R. V. (2015) · Scientific Reports · doi:10.1038/srep10494 · Cited by 248
Near-Infrared spectroscopy: Theory and applications
Wahr, J. A., Tremper, K. K., Samra, S., & Delpy, D. T. (1996) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(96)80107-8 · Cited by 227
Self-citationValidation in Volunteers of a Near-Infrared Spectroscope for Monitoring Brain Oxygenation In Vivo
Pollard, V., Prough, D. S., DeMelo, A. E., Deyo, D. J., Uchida, T., & Stoddart, H. F. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199602000-00010 · Cited by 225
Ekkekakis, P. (2009) · Journal of Sport and Exercise Psychology · doi:10.1123/jsep.31.4.505 · Cited by 218
“Consistent with this idea, using a simplified model of the head, consisting of two concentric spheres, Hiraoka et al. (1993) showed that the influence of superficial layers decreases as the distance between the source and the detector increases.”
MethodIndependent-component analysis of skin color image
Tsumura, N., Haneishi, H., & Miyake, Y. (1999) · Journal of the Optical Society of America A · doi:10.1364/josaa.16.002169 · Cited by 212
An investigation of light transport through scattering bodies with non-scattering regions
Firbank, M., Arridge, S. R., Schweiger, M., & Delpy, D. T. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/4/012 · Cited by 189
“Some further theoretical studies have been reported in the literature which investigate the effect of tissue inhomogeneity, using models in which there are two or more layers with different optical properties (van Gemert et al 1989, Haselgrove et al 1992, Hiraoka et al 1993 ).”
Self-citationFirbank, M., Okada, E., & Delpy, D. T. (1998) · NeuroImage · doi:10.1006/nimg.1998.0348 · Cited by 172
“In addition, we performed a Monte Carlo simulation (Hiraoka et al., 1993) of a concentric cylinder with FIG.”
Self-citationHigh-density diffuse optical tomography for imaging human brain function
Wheelock, M. D., Culver, J. P., & Eggebrecht, A. T. (2019) · Review of Scientific Instruments · doi:10.1063/1.5086809 · Cited by 168
Tsumura, N., Ojima, N., Sato, K., Shiraishi, M., Shimizu, H., Nabeshima, H., Akazaki, S., Hori, K., & Miyake, Y. (2003) · ACM Transactions on Graphics · doi:10.1145/882262.882344 · Cited by 162
Funane, T., Atsumori, H., Katura, T., Obata, A. N., Sato, H., Tanikawa, Y., Okada, E., & Kiguchi, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.02.026 · Cited by 158
“The signal amplitude of the continuouswave (CW) NIRS system is proportional to the partial path length where the blood volume changes (Hiraoka et al., 1993; Maki et al., 1995).”
BackgroundMethodInfluentialGender variations in the optical properties of skin in murine animal models
Calabro, K., Curtis, A., Galarneau, J.-R., Krucker, T., & Bigio, I. J. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3525565 · Cited by 58
Metadata
- Authors
- Hiraoka, M., Firbank, M., Essenpreis, M., Cope, M., Arridge, S. R., Zee, P. V. D., & Delpy, D. T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1993-12-01
- Volume
- 38
- Issue
- 12
- Pages
- 1859-1876
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2070230712
- Cited by
- 374
- References
- 27
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.