A Monte Carlo investigation of optical pathlength in inhomogeneous tissue and its application to near-infrared spectroscopy
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
In order to quantify near-infrared spectroscopic (NIRS) data on an inhomogeneous medium, knowledge of the contribution of the various parts of the medium to the total NIRS signal is required. This is particularly true in the monitoring of cerebral oxygenation by NIRS, where the contribution of the overlying tissues must be known. The concept of the time point spread function (TPSF), which is used extensively in NIRS to determine the effective optical pathlength, is expanded to the more general inhomogeneous case. This is achieved through the introduction of the partial differential pathlength, which is the effective optical pathlength in the inhomogeneous medium, and an analytical proof of the applicability of the modified Beer-Lambert law in an inhomogeneous medium is shown. To demonstrate the use of partial differential pathlength, a Monte Carlo simulation of a two-concentric-sphere medium representing a simplified structure of the head is presented, and the possible contribution of the overlying medium to the total NIRS signal is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Self-citationPatterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Wyatt, J. S., Delpy, D. T., Cope, M., Wray, S., & Reynolds, E. O. R. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90467-8 · Cited by 876
Self-citationA Monte Carlo model for the absorption and flux distributions of light in tissue
Wilson, B. C., & Adam, G. (1983) · Medical Physics · doi:10.1118/1.595361 · Cited by 690
A finite element approach for modeling photon transport in tissue
Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993) · Medical Physics · doi:10.1118/1.597069 · Cited by 635
Self-citationArridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Self-citationMethods of Quantitating Cerebral Near Infrared Spectroscopy Data
Cope, M., Delpy, D. T., Reynolds, E. O. R., Wray, S., Wyatt, J., & van der Zee, P. (1988) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-9510-6_21 · Cited by 502
Self-citationFlock, S. T., Patterson, M. S., Wilson, B. C., & Wyman, D. R. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1989.1173624 · Cited by 489
Quantitation of cerebral blood volume in human infants by near-infrared spectroscopy
Wyatt, J. S., Cope, M., Delpy, D. T., Richardson, C. E., Edwards, A. D., Wray, S., & Reynolds, E. O. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.1086 · Cited by 442
Self-citationvan der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427
Self-citationFishkin, J. B., & Gratton, E. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.000127 · Cited by 385
COTSIDE MEASUREMENT OF CEREBRAL BLOOD FLOW IN ILL NEWBORN INFANTS BY NEAR INFRARED SPECTROSCOPY
Edwards, A. D., Richardson, C., Cope, M., Wyatt, J. S., Delpy, D. T., & Reynolds, E. O. R. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92418-x · Cited by 370
Self-citationNoninvasive Monitoring of Cerebral Oxygenation in Preterm Infants: Preliminary Observations
Brazy, J. E., Lewis, D. V., Mitnick, M. H., & vander Vliet, F. F. J. (1985) · Pediatrics · doi:10.1542/peds.75.2.217 · Cited by 356
Measurement of the optical properties of the skull in the wavelength range 650-950 nm
Firbank, M., Hiraoka, M., Essenpreis, M., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/4/002 · Cited by 305
Self-citationSpectral dependence of temporal point spread functions in human tissues
Essenpreis, M., Elwell, C. E., Cope, M., van der Zee, P., Arridge, S. R., & Delpy, D. T. (1993) · Applied Optics · doi:10.1364/ao.32.000418 · Cited by 195
Self-citationCondensed Monte Carlo simulations for the description of light transport
Graaff, R., Koelink, M. H., de Mul, F. F. M., Zijlstra, W. G., Dassel, A. C. M., & Aarnoudse, J. G. (1993) · Applied Optics · doi:10.1364/ao.32.000426 · Cited by 184
Skov, L., Pryds, O., & Greisen, G. (1991) · Pediatric Research · doi:10.1203/00006450-199112000-00016 · Cited by 168
Reconstruction methods for infrared absorption imaging
Arridge, S., van der Zee, P., Cope, M., & Delpy, D. T. (1991) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.44191 · Cited by 110
Self-citationElwell, C. E., Cope, M., Edwards, A. D., Wyatt, J. S., Reynolds, E. O. R., & Delpy, D. T. (1992) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-3428-0_25 · Cited by 98
Self-citationChance, B., Maris, M. B., Sorge, J., & Zhang, M. Z. (1990) · SPIE Proceedings · doi:10.1117/12.17711 · Cited by 94
Spatial localization of absorbing bodies by interfering diffusive photon-density waves
Knüttel, A., Schmitt, J. M., & Knutson, J. R. (1993) · Applied Optics · doi:10.1364/ao.32.000381 · Cited by 86
Ferrari, M., Marchis, C. D., Giannini, I., Nicola, A. D., Agosti, M. A., Nodari, S., & Bucci, G. (1986) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-5188-7_27 · Cited by 67
Cui, W., & Ostrander, L. E. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.121651 · Cited by 64
The Effect of Optode Positioning on Optical Pathlength in Near Infrared Spectroscopy of Brain
van der Zee, P., Arridge, S., Cope, M., & Delpy, D. T. (1990) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-8181-5_11 · Cited by 62
Self-citationFerrari, M., Zanette, E. M., Giannini, I., Sideri, G., Fieschi, C., & Carpi, A. (1986) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-5188-7_28 · Cited by 55
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
“By using diffusion approximations and finite-element or Monte-Carlobased computational methods [12,13,16,73–76], we can estimate the sensitivity profile for each source–detector pair on the basis of the optical properties of the tissue as shown in Fig 1(a).”
BackgroundMethodFang, Q., & Boas, D. A. (2009) · Optics Express · doi:10.1364/oe.17.020178 · Cited by 1,003
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
The modified Beer–Lambert law revisited
Kocsis, L., Herman, P., & Eke, A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/5/n02 · Cited by 679
Metadata
- Authors
- Hiraoka, M., Firbank, M., Essenpreis, M., Cope, M., Arridge, S. R., Zee, P. V. D., & Delpy, D. T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1993-12-01
- Volume
- 38
- Issue
- 12
- Pages
- 1859-1876
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2070230712
- Cited by
- 374
- References
- 27
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.