The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Three experimental techniques based on automatic swept-frequency network and impedance analysers were used to measure the dielectric properties of tissue in the frequency range 10 Hz to 20 GHz. The technique used in conjunction with the impedance analyser is described. Results are given for a number of human and animal tissues, at body temperature, across the frequency range, demonstrating that good agreement was achieved between measurements using the three pieces of equipment. Moreover, the measured values fall well within the body of corresponding literature data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
Self-citationThe dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Self-citationLinear and nonlinear electrode polarization and biological materials
Schwan, H. P. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368531 · Cited by 233
Anisotropy in the dielectric properties of skeletal muscle
Epstein, B. R., & Foster, K. R. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446406 · Cited by 219
Cited by
Items 101–109 of 109
Modeling of capacitive resonant wireless power and data transfer to deep biomedical implants
Narayanamoorthi, R. (2019) · IEEE Transactions on Components, Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2019.2922046 · Cited by 62
“To minimize the loss, an optimum value of the frequency needs to be chosen as resonant frequency [30].”
BackgroundMulti-disciplinary challenges in tissue modeling for wireless electromagnetic powering: a review
Bocan, K. N., Mickle, M. H., & Sejdic, E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2748338 · Cited by 41
“As evidenced by differences in water content among tissue types and differences in measured parameters reported in [6] and [7], changes in tissue water content affect tissue dielectric properties.”
BackgroundEffects of frequency-dependent membrane capacitance on neural excitability
Howell, B., Medina, L. E., & Grill, W. M. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056015 · Cited by 39
Raben, H., Kämmerer, P. W., Bader, R., & van Rienen, U. (2019) · Applied Sciences · doi:10.3390/app9102160 · Cited by 34
“These quantities are highly frequency-dependent and their values at the stimulation frequency of f = 20 Hz have been taken from the literature [50,51] in the case of the biological tissues (a practical online tool can be found at [52]).”
BackgroundCruciani, S., Campi, T., Maradei, F., & Feliziani, M. (2014) · 2014 International Symposium on Electromagnetic Compatibility · doi:10.1109/emceurope.2014.6930874 · Cited by 34
“The frequency dispersive biological materials are modeled using a 4-Cole-Cole dispersion relation [5]-[7].”
MethodA broad dual-band implantable antenna for RF energy harvesting and data transmitting
Fan, Y., Liu, X., & Xu, C. (2022) · Micromachines · doi:10.3390/mi13040563 · Cited by 33
“In the simulation of the dual-band antenna, the dielectric properties of human tissues, such as relative permittivity and loss tangent, should be set as the values at the center frequency in the two target bands [25].”
BackgroundSAR thresholds for electromagnetic exposure using functional thermal dose limits
Adibzadeh, F., Paulides, M. M., & van Rhoon, G. C. (2018) · International Journal of Hyperthermia · doi:10.1080/02656736.2018.1424945 · Cited by 23
“The dielectric parameters were taken from the database of Gabriel [20,21].”
MethodKainz, W., Alesch, F., & Chan, D. D. (2003) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-2-11 · Cited by 16
Laissaoui, A., Nekhoul, B., Mezoued, S., & Poljak, D. (2017) · Automatika · doi:10.1080/00051144.2018.1435341 · Cited by 2
“The body model consists of a material with parameters simulating a muscle tissue: the frequency-dependent permittivity and electrical conductivity (see Table 4) [15].”
Background
Metadata
- Authors
- Gabriel, S., Lau, R. W., & Gabriel, C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1996-11-01
- Volume
- 41
- Issue
- 11
- Pages
- 2251-2269
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2022981781
- Cited by
- 4,270
- References
- 4
- FWCI
- 16.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.