The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Three experimental techniques based on automatic swept-frequency network and impedance analysers were used to measure the dielectric properties of tissue in the frequency range 10 Hz to 20 GHz. The technique used in conjunction with the impedance analyser is described. Results are given for a number of human and animal tissues, at body temperature, across the frequency range, demonstrating that good agreement was achieved between measurements using the three pieces of equipment. Moreover, the measured values fall well within the body of corresponding literature data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
Self-citationThe dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Self-citationLinear and nonlinear electrode polarization and biological materials
Schwan, H. P. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368531 · Cited by 233
Anisotropy in the dielectric properties of skeletal muscle
Epstein, B. R., & Foster, K. R. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446406 · Cited by 219
Cited by
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
Self-citationThe dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Self-citationModelling and analysis of local field potentials for studying the function of cortical circuits
Einevoll, G. T., Kayser, C., Logothetis, N. K., & Panzeri, S. (2013) · Nature Reviews Neuroscience · doi:10.1038/nrn3599 · Cited by 857
Irreversible Electroporation: A New Ablation Modality — Clinical Implications
Rubinsky, B., Onik, G., & Mikus, P. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600106 · Cited by 781
Nagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/001 · Cited by 774
Electrical conductivity of tissue at frequencies below 1 MHz
Gabriel, C., Peyman, A., & Grant, E. H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/16/002 · Cited by 716
Self-citationRevealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“…of brain tissue conduction, such as anisotropy (Nicholson and Freeman, 1975; Logothetis et al., 2007); anisotropy and inhomo-geneity (Ranck, 1963a,b; Hoeltzell and Dykes, 1979; Goto et al., 2010); and capacitive property (Gabriel et al., 1996a,b; Bédard et al., 2004; Bédard and Destexhe, 2009).”
Increasing Human Brain Excitability by Transcranial High-Frequency Random Noise Stimulation
Terney, D., Chaieb, L., Moliadze, V., Antal, A., & Paulus, W. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4248-08.2008 · Cited by 680
Karacolak, T., Hood, A. Z., & Topsakal, E. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.919373 · Cited by 633
Optimized multi-electrode stimulation increases focality and intensity at target
Dmochowski, J. P., Datta, A., Bikson, M., Su, Y., & Parra, L. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046011 · Cited by 590
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Edwards, D., Cortes, M., Datta, A., Minhas, P., Wassermann, E. M., & Bikson, M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.042 · Cited by 468
Heating technology for malignant tumors: a review
Kok, H. P., Cressman, E. N. K., Ceelen, W., Brace, C. L., Ivkov, R., Grüll, H., ter Haar, G., Wust, P., & Crezee, J. (2020) · International Journal of Hyperthermia · doi:10.1080/02656736.2020.1779357 · Cited by 422
Microwave-Based Stroke Diagnosis Making Global Prehospital Thrombolytic Treatment Possible
Persson, M., Fhager, A., Trefna, H. D., Yu, Y., McKelvey, T., Pegenius, G., Karlsson, J.-E., & Elam, M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2330554 · Cited by 380
Electric Properties of Tissues
Miklavčič, D., Pavšelj, N., & Hart, F. X. (2006) · Wiley Encyclopedia of Biomedical Engineering · doi:10.1002/9780471740360.ebs0403 · Cited by 376
Rossmanna, C., & Haemmerich, D. (2014) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2015012486 · Cited by 370
Pesaran, B., Vinck, M., Einevoll, G. T., Sirota, A., Fries, P., Siegel, M., Truccolo, W., Schroeder, C. E., & Srinivasan, R. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0171-8 · Cited by 370
Oostenveld, R., & Oostendorp, T. F. (2002) · Human Brain Mapping · doi:10.1002/hbm.10061 · Cited by 368
Fully implantable and bioresorbable cardiac pacemakers without leads or batteries
Choi, Y. S., Yin, R. T., Pfenniger, A., Koo, J., Avila, R., Benjamin Lee, K., Chen, S. W., Lee, G., Li, G., Qiao, Y., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00948-x · Cited by 361
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
“15 1 Measured ex vivo at 100 kHz, adapted from [92–94].”
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
“The optimized PTE, η, can be approximated using the dielectric tissue dispersion of the Cole-Cole relaxation model [55,57]: η = RL RL + RT (1− |τ|2) (1)”
MethodThe Human Body Characteristics as a Signal Transmission Medium for Intrabody Communication
Cho, N., Yoo, J., Song, S.-J., Lee, J., Jeon, S., & Yoo, H.-J. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.895640 · Cited by 355
Maximum Achievable Efficiency in Near-Field Coupled Power-Transfer Systems
Zargham, M., & Gulak, P. G. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2174794 · Cited by 349
The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies
Faes, T. J. C., Meij, H. A. V. D., Munck, J. C. D., & Heethaar, R. M. (1999) · Physiological Measurement · doi:10.1088/0967-3334/20/4/201 · Cited by 347
Kiourti, A., & Nikita, K. S. (2012) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2012.2201078 · Cited by 337
Determination of Electric Conductivity and Local SAR Via B1 Mapping
Katscher, U., Voigt, T., Findeklee, C., Vernickel, P., Nehrke, K., & DÖssel, O. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2015757 · Cited by 329
Dielectric Properties of Tissues
(2008) · Encyclopedia of Biomaterials and Biomedical Engineering, Second Edition · doi:10.1081/e-ebbe2-120041843 · Cited by 319
Opitz, A., Falchier, A., Yan, C.-G., Yeagle, E. M., Linn, G. S., Megevand, P., Thielscher, A., Deborah A., R., Milham, M. P., Mehta, A. D., et al. (2016) · Scientific Reports · doi:10.1038/srep31236 · Cited by 317
Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor
Choi, H., Naylon, J., Luzio, S., Beutler, J., Birchall, J., Martin, C., & Porch, A. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2472019 · Cited by 312
Microwave Breast Imaging: Clinical Advances and Remaining Challenges
O’Loughlin, D., O’Halloran, M., Moloney, B. M., Glavin, M., Jones, E., & Elahi, M. A. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2809541 · Cited by 307
La Gioia, A., Porter, E., Merunka, I., Shahzad, A., Salahuddin, S., Jones, M., & O’Halloran, M. (2018) · Diagnostics · doi:10.3390/diagnostics8020040 · Cited by 297
Electrical impedance myography: Background, current state, and future directions
Rutkove, S. B. (2009) · Muscle & Nerve · doi:10.1002/mus.21362 · Cited by 292
Dimbylow, P. J. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/3/003 · Cited by 284
A Theoretical Model for the Margination of Particles within Blood Vessels
Decuzzi, P., Lee, S., Bhushan, B., & Ferrari, M. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8976-5 · Cited by 280
Dimbylow, P. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/6/002 · Cited by 276
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
Huang, F.-J., Lee, C.-M., Chang, C.-L., Chen, L.-K., Yo, T.-C., & Luo, C.-H. (2011) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2011.2152317 · Cited by 268
On the importance of electrode parameters for shaping electric field patterns generated by tDCS
Saturnino, G. B., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.067 · Cited by 263
Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245
Changes in the dielectric properties of rat tissue as a function of age at microwave frequencies
Peyman, A., Rezazadeh, A. A., & Gabriel, C. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/6/303 · Cited by 244
Self-citationMillimeter-wave interactions with the human body: state of knowledge and recent advances
Zhadobov, M., Chahat, N., Sauleau, R., Le Quement, C., & Le Drean, Y. (2011) · International Journal of Microwave and Wireless Technologies · doi:10.1017/s1759078711000122 · Cited by 244
“2 mm, we computed the transmission coefficient at 60 GHz for this range using Gabriel’s permittivity model [14].”
BackgroundMethodWu, T., Rappaport, T. S., & Collins, C. M. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2014.2377587 · Cited by 243
“However, these data have natural variability in the structure and composition of the biological tissues [55].”
A Compact UWB Antenna for On-Body Applications
Chahat, N., Zhadobov, M., Sauleau, R., & Ito, K. (2011) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2011.2109361 · Cited by 242
“The muscle dielectric properties are well characterized up to 20 GHz [24].”
BackgroundModeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241
“To be more realistic, one should discriminate between the skin, fat, muscle, blood, and bone properties [26], [27].”
Sersa, G., Jarm, T., Kotnik, T., Coer, A., Podkrajsek, M., Sentjurc, M., Miklavcic, D., Kadivec, M., Kranjc, S., Secerov, A., et al. (2008) · British Journal of Cancer · doi:10.1038/sj.bjc.6604168 · Cited by 233
“Both regions were assigned an electric conductivity of 0.3 S m 1, which is an average value of reported bulk electric conductivities of soft tissues (including epithelial and tumour tissues) that range from 0.1 to 0.5 S m 1 (Geddes and Barker, 1967; Duck, 1990; Gabriel et al, 1996).”
BackgroundMethodInfluentialBossetti, C. A., Birdno, M. J., & Grill, W. M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/005 · Cited by 232
Electromagnetic Energy Harvesting and Wireless Power Transmission: A Unified Approach
Costanzo, A., Dionigi, M., Masotti, D., Mongiardo, M., Monti, G., Tarricone, L., & Sorrentino, R. (2014) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2355261 · Cited by 230
Fully Wireless Implantable Cardiovascular Pressure Monitor Integrated with a Medical Stent
Chow, E. Y., Chlebowski, A. L., Chakraborty, S., Chappell, W. J., & Irazoqui, P. P. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2041058 · Cited by 222
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
“over an increase in frequency between 10 Hz and 20 GHz for different types of human and animal tissue (liver, muscle, skin, tongue, adipose tissue) measured at body temperature [174].”
BackgroundRecent Advances in Microwave Imaging for Breast Cancer Detection
Kwon, S., & Lee, S. (2016) · International Journal of Biomedical Imaging · doi:10.1155/2016/5054912 · Cited by 219
“This is because malignant tissues contain much water and are more active than normal [40, 41].”
BackgroundDeng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016007 · Cited by 216
Finding Common Ground: A Survey of Capacitive Sensing in Human-Computer Interaction
Grosse-Puppendahl, T., Holz, C., Cohn, G., Wimmer, R., Bechtold, O., Hodges, S., Reynolds, M. S., & Smith, J. R. (2017) · Proceedings of the 2017 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3025453.3025808 · Cited by 214
“Extensive research has been conducted in modeling the electric properties of the human body—most fundamentally gaining an understanding of the impedance of different types of tissues [49, 51].”
BackgroundElectrical impedance characterization of normal and cancerous human hepatic tissue
Laufer, S., Ivorra, A., Reuter, V. E., Rubinsky, B., & Solomon, S. B. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/7/009 · Cited by 209
Design of an Implantable Slot Dipole Conformal Flexible Antenna for Biomedical Applications
Scarpello, M. L., Kurup, D., Rogier, H., Vande Ginste, D., Axisa, F., Vanfleteren, J., Joseph, W., Martens, L., & Vermeeren, G. (2011) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2011.2163761 · Cited by 206
Simulating Transcranial Direct Current Stimulation With a Detailed Anisotropic Human Head Model
Rampersad, S. M., Janssen, A. M., Lucka, F., Aydin, U., Lanfer, B., Lew, S., Wolters, C. H., Stegeman, D. F., & Oostendorp, T. F. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2308997 · Cited by 206
Macroscopic Models of Local Field Potentials and the Apparent 1/f Noise in Brain Activity
Bédard, C., & Destexhe, A. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2008.12.3951 · Cited by 206
“We have shown that the presenc e of ionic diffusion allows the model to account quantitatively for the macroscopic measurement s of the frequency dependence of electric parameters in cortical tissue (15).”
InfluentialAn inductive power link for a wireless endoscope
Lenaerts, B., & Puers, R. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.06.015 · Cited by 204
“Biological tissue is slightly conductive (Gabriel et al., 1996a,b) and will therefore draw power from an electromagnetic field.”
BackgroundPerspectives with cryogenic RF probes in biomedical MRI
Darrasse, L. (2003) · Biochimie · doi:10.1016/j.biochi.2003.09.016 · Cited by 201
Thermal and nonthermal mechanisms of interaction of radio-frequency energy with biological systems
Foster, K. R. (2000) · IEEE Transactions on Plasma Science · doi:10.1109/27.842819 · Cited by 201
Simulation techniques in hyperthermia treatment planning
Paulides, M. M., Stauffer, P. R., Neufeld, E., Maccarini, P. F., Kyriakou, A., Canters, R. A. M., Diederich, C. J., Bakker, J. F., & Van Rhoon, G. C. (2013) · International Journal of Hyperthermia · doi:10.3109/02656736.2013.790092 · Cited by 199
“For dielectric properties, variations of 30% or more have been measured in post-mortem humans [18,19], and even greater variations were shown in breast [20,21] and brain, by means of MR measurements [22].”
Complex permittivities of breast tumor tissues obtained from cancer surgeries
Sugitani, T., Kubota, S.-I., Kuroki, S.-I., Sogo, K., Arihiro, K., Okada, M., Kadoya, T., Hide, M., Oda, M., & Kikkawa, T. (2014) · Applied Physics Letters · doi:10.1063/1.4885087 · Cited by 199
Song, J. W., Ryu, H., Bai, W., Xie, Z., Vázquez-Guardado, A., Nandoliya, K., Avila, R., Lee, G., Song, Z., Kim, J., et al. (2023) · Science Advances · doi:10.1126/sciadv.ade4687 · Cited by 199
Transcranial Current Brain Stimulation (tCS): Models and Technologies
Ruffini, G., Wendling, F., Merlet, I., Molaee-Ardekani, B., Mekonnen, A., Salvador, R., Soria-Frisch, A., Grau, C., Dunne, S., & Miranda, P. C. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2200046 · Cited by 197
Human skin permittivity determined by millimeter wave reflection measurements
Alekseev, S. I., & Ziskin, M. C. (2007) · Bioelectromagnetics · doi:10.1002/bem.20308 · Cited by 194
“Biological tissue permittivity in thegigahertz frequency range is characterized by the g dispersion which results from the polarization of free water molecules [Grant, 1982; Foster and Schwan, 1986; Gabriel et al., 1996].”
Lazebnik, M., Converse, M. C., Booske, J. H., & Hagness, S. C. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/7/022 · Cited by 194
Radio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels
Yilmaz, T., Foster, R., & Hao, Y. (2019) · Diagnostics · doi:10.3390/diagnostics9010006 · Cited by 192
Characterization of textile electrodes and conductors using standardized measurement setups
Beckmann, L., Neuhaus, C., Medrano, G., Jungbecker, N., Walter, M., Gries, T., & Leonhardt, S. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/2/009 · Cited by 192
“Such conductivity is equivalent to the conductance of wet skin tissue at 10 kHz (see Gabriel et al 1996).”
BackgroundThermal effects of bioimplants
Lazzi, G. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511503 · Cited by 192
The human body and millimeter-wave wireless communication systems: Interactions and implications
Wu, T., Rappaport, T. S., & Collins, C. M. (2015) · 2015 IEEE International Conference on Communications (ICC) · doi:10.1109/icc.2015.7248688 · Cited by 187
“However, these data reflect natural variability in structure and composition of the biological tissues [16].”
BackgroundMoliadze, V., Antal, A., & Paulus, W. (2010) · The Journal of Physiology · doi:10.1113/jphysiol.2010.196998 · Cited by 185
“Skull thickness and the related distance between the stimulation electrode and cortex is probably not a problem: according to Gabriel et al. (1996) in the frequency range employed here a linear resistance can be assumed for the tissues between the skin and the brain without an attenuation of the…”
BackgroundWireless Power Delivery to Flexible Subcutaneous Implants Using Capacitive Coupling
Jegadeesan, R., Agarwal, K., Guo, Y.-X., Yen, S.-C., & Thakor, N. V. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2615623 · Cited by 184
Monitoring vital signs using millimeter wave
Yang, Z., Pathak, P. H., Zeng, Y., Liran, X., & Mohapatra, P. (2016) · Proceedings of the 17th ACM International Symposium on Mobile Ad Hoc Networking and Computing · doi:10.1145/2942358.2942381 · Cited by 183
“We observe that our measurements are in agreement with permittivity models of [10] and [14].”
ResultTutorial: Electroporation of cells in complex materials and tissue
Rems, L., & Miklavčič, D. (2016) · Journal of Applied Physics · doi:10.1063/1.4949264 · Cited by 180
Broadband dielectric spectrometry of liquids and biosystems
Kaatze, U., & Feldman, Y. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/2/r01 · Cited by 174
Assessing Human Exposure to Electromagnetic Fields From Wireless Power Transmission Systems
Christ, A., Douglas, M., Nadakuduti, J., & Kuster, N. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2245851 · Cited by 173
Ephaptic coupling to endogenous electric field activity: Why bother?
Anastassiou, C. A., & Koch, C. (2015) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2014.09.002 · Cited by 171
Bashirullah, R. (2010) · IEEE Microwave Magazine · doi:10.1109/mmm.2010.938579 · Cited by 171
“For a critical review of the electrical properties of biological tissue in the body, see [17].”
BackgroundHopfer, M., Planas, R., Hamidipour, A., Henriksson, T., & Semenov, S. (2017) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2017.2732225 · Cited by 168
“Its dielectric properties can vary considerably [4]–[8].”
Yilmaz, T., Foster, R., & Hao, Y. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2313139 · Cited by 168
“45 GHz), also given in Table III [19], [20].”
BackgroundMethodResultInfluentialUltrawideband Textile Antenna for Wearable Microwave Medical Imaging Applications
Lin, X., Chen, Y., Gong, Z., Seet, B.-C., Huang, L., & Lu, Y. (2020) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2020.2970072 · Cited by 166
“prototype with the phantom within the interested frequency range [47], [48].”
BackgroundInfluentialPetrovic, V. L., Jankovic, M. M., Lupsic, A. V., Mihajlovic, V. R., & Popovic-Bozovic, J. S. (2019) · IEEE Access · doi:10.1109/access.2019.2921240 · Cited by 165
Lee, H.-M., Kwon, K. Y., Li, W., & Ghovanloo, M. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2355814 · Cited by 161
Assessment of Human Exposure to Electromagnetic Fields: Review and Future Directions
Hirata, A., Diao, Y., Onishi, T., Sasaki, K., Ahn, S., Colombi, D., De Santis, V., Laakso, I., Giaccone, L., Wout, J., et al. (2021) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2021.3109249 · Cited by 161
“Conventionally, tissue conductivity values have been estimated based on data from animal tissue measurements [23].”
Broadband dielectric spectroscopy on human blood
Wolf, M., Gulich, R., Lunkenheimer, P., & Loidl, A. (2011) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2011.05.012 · Cited by 161
Conductivity of living intracranial tissues
Latikka, J., Kuurne, T., & Eskola, H. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/6/302 · Cited by 161
Hearables: Multimodal physiological in-ear sensing
Goverdovsky, V., von Rosenberg, W., Nakamura, T., Looney, D., Sharp, D. J., Papavassiliou, C., Morrell, M. J., & Mandic, D. P. (2017) · Scientific Reports · doi:10.1038/s41598-017-06925-2 · Cited by 159
Zargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115
“cole-cole models provided in [32]–[35].”
Wireless communication with implanted medical devices using the conductive properties of the body
Ferguson, J. E., & Redish, A. D. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.16 · Cited by 112
Chow, E., Morris, M., & Irazoqui, P. (2013) · IEEE Microwave Magazine · doi:10.1109/mmm.2013.2248586 · Cited by 111
Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants
Wilke, R. G. H., Moghadam, G. K., Lovell, N. H., Suaning, G. J., & Dokos, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046016 · Cited by 110
“Also, the model only considers electrostatic effects, not taking into account time-dependent processes introduced by the highly complex electrode–tissue interface [18] or dielectric properties of the tissue itself [10].”
BackgroundKainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109
“[56], [63] is known to be less accurate.”
Wireless power transfer system for deep-implanted biomedical devices
Iqbal, A., Sura, P. R., Al-Hasan, M., Mabrouk, I. B., & Denidni, T. A. (2022) · Scientific Reports · doi:10.1038/s41598-022-18000-6 · Cited by 105
Kandadai, M. A., Raymond, J. L., & Shaw, G. J. (2012) · Materials Science and Engineering: C · doi:10.1016/j.msec.2012.07.024 · Cited by 102
Pitfalls in the dipolar model for the neocortical EEG sources
Riera, J. J., Ogawa, T., Goto, T., Sumiyoshi, A., Nonaka, H., Evans, A., Miyakawa, H., & Kawashima, R. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00098.2011 · Cited by 98
“0 10 ε ε ∼ for brain tissues [1,2], the electric”
Rapid Mood-Elevating Effects of Low Field Magnetic Stimulation in Depression
Rohan, M. L., Yamamoto, R. T., Ravichandran, C. T., Cayetano, K. R., Morales, O. G., Olson, D. P., Vitaliano, G., Paul, S. M., & Cohen, B. M. (2014) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.10.024 · Cited by 97
Review on medical implantable antenna technology and imminent research challenges
Soliman, M. M., Chowdhury, M. E. H., Khandakar, A., Islam, M. T., Qiblawey, Y., Musharavati, F., & Zal Nezhad, E. (2021) · Sensors · doi:10.3390/s21093163 · Cited by 95
Optical properties of tissue measured using terahertz pulsed imaging
Berry, E., Fitzgerald, A. J., Zinov'ev, N. N., Walker, G. C., Homer-Vanniasinkam, S., Sudworth, C. D., Miles, R. E., Chamberlain, J. M., & Smith, M. A. (2003) · SPIE Proceedings · doi:10.1117/12.479993 · Cited by 92
The use of electric fields in tissue engineering: A review
Markx, G. H. (2008) · Organogenesis · doi:10.4161/org.5799 · Cited by 92
A Wireless Magnetoresistive Sensing System for an Intraoral Tongue-Computer Interface
Park, H., Kiani, M., Lee, H.-M., Kim, J., Block, J., Gosselin, B., & Ghovanloo, M. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2227962 · Cited by 79
“TABLE I FREQUENCY-DEPENDENT ATTENUATION CHARACTERISTICS OF TISSUE [33]”
A biosafety comparison between capacitive and inductive coupling in biomedical implants
Al-Kalbani, A. I., Yuce, M. R., & Redoute, J.-M. (2014) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2014.2328375 · Cited by 69
“The relative permittivity of human muscle tissue decreases as the transmit frequency increases [6].”
Background
Metadata
- Authors
- Gabriel, S., Lau, R. W., & Gabriel, C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1996-11-01
- Volume
- 41
- Issue
- 11
- Pages
- 2251-2269
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2022981781
- Cited by
- 4,270
- References
- 4
- FWCI
- 16.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.