High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
A Bayesian method is described for reconstruction of high-resolution 3D images from the microPET small-animal scanner. Resolution recovery is achieved by explicitly modelling the depth dependent geometric sensitivity for each voxel in combination with an accurate detector response model that includes factors due to photon pair non-collinearity and inter-crystal scatter and penetration. To reduce storage and computational costs we use a factored matrix in which the detector response is modelled using a sinogram blurring kernel. Maximum a posteriori (MAP) images are reconstructed using this model in combination with a Poisson likelihood function and a Gibbs prior on the image. Reconstructions obtained from point source data using the accurate system model demonstrate a potential for near-isotropic FWHM resolution of approximately 1.2 mm at the center of the field of view compared with approximately 2 mm when using an analytic 3D reprojection (3DRP) method with a ramp filter. These results also show the ability of the accurate system model to compensate for resolution loss due to crystal penetration producing nearly constant radial FWHM resolution of 1 mm out to a 4 mm radius. Studies with a point source in a uniform cylinder indicate that as the resolution of the image is reduced to control noise propagation the resolution obtained using the accurate system model is superior to that obtained using 3DRP at matched background noise levels. Additional studies using pie phantoms with hot and cold cylinders of diameter 1-2.5 mm and 18FDG animal studies appear to confirm this observation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Analytic 3D image reconstruction using all detected events
Kinahan, P. E., & Rogers, J. G. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34585 · Cited by 767
Exact and approximate rebinning algorithms for 3-D PET data
Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563660 · Cited by 758
Penalized weighted least-squares image reconstruction for positron emission tomography
Fessler, J. A. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293921 · Cited by 611
MicroPET: a high resolution PET scanner for imaging small animals
Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., et al. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.596981 · Cited by 609
Self-citationA local update strategy for iterative reconstruction from projections
Sauer, K., & Bouman, C. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193196 · Cited by 494
A unified approach to statistical tomography using coordinate descent optimization
Bouman, C. A., & Sauer, K. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.491321 · Cited by 442
A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography
Browne, J., & de Pierro, A. B. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538946 · Cited by 424
Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography
Snyder, D. L., Miller, M. I., Thomas, L. J., & Politte, D. G. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307831 · Cited by 421
Bayesian reconstruction of PET images: methodology and performance analysis
Mumcuoglu, E. Ü., Leahy, R. M., & Cherry, S. R. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/9/015 · Cited by 214
Self-citationA system for the 3D reconstruction of retracted-septa PET data using the EM algorithm
Johnson, C. A., Yan, Y., Carson, R. E., Martino, R. L., & Daube-Witherspoon, M. E. (1995) · IEEE Transactions on Nuclear Science · doi:10.1109/23.467875 · Cited by 93
Parallelization of the EM algorithm for 3-D PET image reconstruction
Chen, C., Lee, S.-Y., & Cho, Z. H. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108585 · Cited by 76
Liang, Z. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293924 · Cited by 60
Compensation for crystal penetration in high resolution positron tomography
Huesman, R. H., Salmeron, E. M., & Baker, J. R. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34612 · Cited by 37
Fast iterative image reconstruction of 3D PET data
Kinahan, P. E., Michel, C. J., Defrise, M., Townsend, D. W., Sibomana, M., Lonneux, M., Newport, D. F., & Luketich, J. D. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1996.588009 · Cited by 35
High resolution and better quantification by tube of response modelling in 3D PET reconstruction
Terstegge, A., Weber, S., Herzog, H. R., Müller-Gärtner, H.-W., & Halling, H. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1996.587931 · Cited by 32
Maximum likelihood reconstruction in fully 3D PET via the SAGE algorithm
Ollinger, J. M., & Goggin, A. S. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1996.587929 · Cited by 28
Cited by
AMIDE: A Free Software Tool for Multimodality Medical Image Analysis
Loening, A. M., & Gambhir, S. S. (2003) · Molecular Imaging · doi:10.1162/15353500200303133 · Cited by 1,018
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536
“to ill-posedness of the reconstruction problem (see examples in [3]), were easier to observe in reconstructions from computer simulated noiseless data.”
BackgroundMethodInfluentialDigimouse: a 3D whole body mouse atlas from CT and cryosection data
Dogdas, B., Stout, D., Chatziioannou, A. F., & Leahy, R. M. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/3/003 · Cited by 524
Self-citationGambhir, S. S., Bauer, E., Black, M. E., Liang, Q., Kokoris, M. S., Barrio, J. R., Iyer, M., Namavari, M., Phelps, M. E., & Herschman, H. R. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.6.2785 · Cited by 450
Iterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
Self-citation
Metadata
- Authors
- Qi, J., Leahy, R. M., Cherry, S. R., Chatziioannou, A., & Farquhar, T. H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1998-04-01
- Volume
- 43
- Issue
- 4
- Pages
- 1001-1013
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2084090004
- Cited by
- 635
- References
- 17
- FWCI
- 16.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.