Comparison of finite-difference transport and diffusion calculations for photon migration in homogeneous and heterogeneous tissues
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
We analyse the limits of the diffusion approximation to the time-independent equation of radiative transfer for homogeneous and heterogeneous biological media. Analytical calculations and finite-difference simulations based on diffusion theory are compared with discrete-ordinate, finite-difference transport calculations. The influence of the ratio of absorption and transport scattering coefficient (mu(a)/mu'(s)) on the accuracy of the diffusion approximation are quantified and different definitions for the diffusion coefficient, D, are discussed. We also address effects caused by void-like heterogeneities in which absorption and scattering are very small compared with the surrounding medium. Based on results for simple homogeneous and heterogeneous systems, we analyse diffusion and transport calculation of light propagation in the human brain. For these simulations we convert density maps obtained from magnetic resonance imaging (MRI) to optical-parameter maps (mu(a) and mu'(s)) of the brain. We show that diffusion theory fails to describe accurately light propagation in highly absorbing regions, such as haematoma, and void-like spaces, such as the ventricles and the subarachnoid space.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Chandrasekhar, S. (1950) · CERN Document Server (European Organization for Nuclear Research) · Cited by 8,702
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Case, K. M., Zweifel, P. F., & Pomraning, G. C. (1968) · Physics Today · doi:10.1063/1.3034554 · Cited by 1,609
Optical-Thermal Response of Laser-Irradiated Tissue
(2011) · Springer eBooks · doi:10.1007/978-90-481-8831-4 · Cited by 1,424
A finite element approach for modeling photon transport in tissue
Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993) · Medical Physics · doi:10.1118/1.597069 · Cited by 635
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Flock, S. T., Patterson, M. S., Wilson, B. C., & Wyman, D. R. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1989.1173624 · Cited by 489
Sevick, E. M., Chance, B., Leigh, J., Nioka, S., & Maris, M. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90339-u · Cited by 360
Photon-measurement density functions Part 2: Finite-element-method calculations
Arridge, S. R., & Schweiger, M. (1995) · Applied Optics · doi:10.1364/ao.34.008026 · Cited by 310
Cited by
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
Fang, Q., & Boas, D. A. (2009) · Optics Express · doi:10.1364/oe.17.020178 · Cited by 1,003
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Optical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625
Boas, D. A., Culver, J. P., Stott, J. J., & Dunn, A. K. (2002) · Optics Express · doi:10.1364/oe.10.000159 · Cited by 599
Mesh-based Monte Carlo method using fast ray-tracing in Plücker coordinates
Fang, Q. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000165 · Cited by 384
Doornbos, R. M. P., Lang, R., Aalders, M. C., Cross, F. W., & Sterenborg, H. J. C. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/4/012 · Cited by 380
Okada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002906 · Cited by 274
Light transport in biological tissue based on the simplified spherical harmonics equations
Klose, A. D., & Larsen, E. W. (2006) · Journal of Computational Physics · doi:10.1016/j.jcp.2006.07.007 · Cited by 268
Strangman, G. E., Li, Z., & Zhang, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066319 · Cited by 262
The inverse source problem based on the radiative transfer equation in optical molecular imaging
Klose, A. D., Ntziachristos, V., & Hielscher, A. H. (2005) · Journal of Computational Physics · doi:10.1016/j.jcp.2004.07.008 · Cited by 207
“Hielscher et al. [101] have shown that the diffusion model inaccurately describes light propagation in this domain.”
BackgroundSelf-citationHolmer, A., Marotz, J., Wahl, P., Dau, M., & Kämmerer, P. W. (2018) · Biomedical Engineering / Biomedizinische Technik · doi:10.1515/bmt-2017-0155 · Cited by 195
Optical imaging and spectroscopy for the study of the human brain: status report
Ayaz, H., Baker, W. B., Blaney, G., Boas, D. A., Bortfeld, H., Brady, K., Brake, J., Brigadoi, S., Buckley, E. M., Carp, S. A., et al. (2022) · Neurophotonics · doi:10.1117/1.nph.9.s2.s24001 · Cited by 170
Near‐Infrared Diffuse Optical Tomography
Hielscher, A. H., Bluestone, A. Y., Abdoulaev, G. S., Klose, A. D., Lasker, J., Stewart, M., Netz, U., & Beuthan, J. (2002) · Disease Markers · doi:10.1155/2002/164252 · Cited by 159
Self-citation
Metadata
- Authors
- Hielscher, A. H., Alcouffe, R. E., & Barbour, R. L.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1998-05-01
- Volume
- 43
- Issue
- 5
- Pages
- 1285-1302
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2065977316
- Cited by
- 332
- References
- 29
- FWCI
- 10.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.