Tissue characterization using magnetic resonance elastography: preliminary results*
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The well-documented effectiveness of palpation as a diagnostic technique for detecting cancer and other diseases has provided motivation for developing imaging techniques for noninvasively evaluating the mechanical properties of tissue. A recently described approach for elasticity imaging, using propagating acoustic shear waves and phase-contrast MRI, has been called magnetic resonance elastography (MRE). The purpose of this work was to conduct preliminary studies to define methods for using MRE as a tool for addressing the paucity of quantitative tissue mechanical property data in the literature. Fresh animal liver and kidney tissue specimens were evaluated with MRE at multiple shear wave frequencies. The influence of specimen temperature and orientation on measurements of stiffness was studied in skeletal muscle. The results demonstrated that all of the materials tested (liver, kidney, muscle and tissue-simulating gel) exhibit systematic dependence of shear stiffness on shear rate. These data are consistent with a viscoelastic model of tissue mechanical properties, allowing calculation of two independent tissue properties from multiple-frequency MRE data: shear modulus and shear viscosity. The shear stiffness of tissue can be substantially affected by specimen temperature. The results also demonstrated evidence of shear anisotropy in skeletal muscle but not liver tissue. The measured shear stiffness in skeletal muscle was found to depend on both the direction of propagation and polarization of the shear waves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Self-citationElastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Physical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Tissue response to mechanical vibrations for “sonoelasticity imaging”
Parker, K. J., Huang, S. R., Musulin, R. A., & Lerner, R. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90003-u · Cited by 478
Magnetic resonance elastography
Muthupillai, R., & Ehman, R. L. (1996) · Nature Medicine · doi:10.1038/nm0596-601 · Cited by 284
Self-citationA new ultrasound tissue-equivalent material.
Burlew, M. M., Madsen, E. L., Zagzebski, J. A., Banjavic, R. A., & Sum, S. W. (1980) · Radiology · doi:10.1148/radiology.134.2.7352242 · Cited by 221
Visualizing tissue compliance with MR imaging
Plewes, D. B., Betty, I., Urchuk, S. N., & Soutar, I. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050620 · Cited by 166
Elasticity reconstructive imaging by means of stimulated echo MRI
Chenevert, T. L., Skovoroda, A. R., O’Donnell, M., & Emelianov, S. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390319 · Cited by 149
Cited by
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Self-citationAssessment of Hepatic Fibrosis With Magnetic Resonance Elastography
Yin, M., Talwalkar, J. A., Glaser, K. J., Manduca, A., Grimm, R. C., Rossman, P. J., Fidler, J. L., & Ehman, R. L. (2007) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2007.06.012 · Cited by 948
Self-citationFass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
Tanter, M., Bercoff, J., Athanasiou, A., Deffieux, T., Gennisson, J.-L., Montaldo, G., Muller, M., Tardivon, A., & Fink, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.002 · Cited by 733
Samani, A., Zubovits, J., & Plewes, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/6/002 · Cited by 707
Gennisson, J.-L., Deffieux, T., Macé, E., Montaldo, G., Fink, M., & Tanter, M. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.013 · Cited by 683
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
MR Elastography of the Liver: Preliminary Results
Rouvière, O., Yin, M., Dresner, M. A., Rossman, P. J., Burgart, L. J., Fidler, J. L., & Ehman, R. L. (2006) · Radiology · doi:10.1148/radiol.2402050606 · Cited by 447
Self-citationAn Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Magnetic resonance elastography of the brain
Kruse, S. A., Rose, G. H., Glaser, K. J., Manduca, A., Felmlee, J. P., Jack, C. R., & Ehman, R. L. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.030 · Cited by 424
Self-citationShear Wave Spectroscopy for In Vivo Quantification of Human Soft Tissues Visco-Elasticity
Deffieux, T., Montaldo, G., Tanter, M., & Fink, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.925077 · Cited by 411
MR Elastography of Breast Cancer: Preliminary Results
McKnight, A. L., Kugel, J. L., Rossman, P. J., Manduca, A., Hartmann, L. C., & Ehman, R. L. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781411 · Cited by 381
Self-citationImaging anisotropic and viscous properties of breast tissue by magnetic resonance‐elastography
Sinkus, R., Tanter, M., Catheline, S., Lorenzen, J., Kuhl, C., Sondermann, E., & Fink, M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20355 · Cited by 380
Accuracy of finite element model‐based multi‐organ deformable image registration
Brock, K. K., Sharpe, M. B., Dawson, L. A., Kim, S. M., & Jaffray, D. A. (2005) · Medical Physics · doi:10.1118/1.1915012 · Cited by 375
Klatt, D., Hamhaber, U., Asbach, P., Braun, J., & Sack, I. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/24/006 · Cited by 333
Sinkus, R., Siegmann, K., Xydeas, T., Tanter, M., Claussen, C., & Fink, M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21404 · Cited by 332
Magnetic resonance imaging of hepatic fibrosis: Emerging clinical applications
Talwalkar, J. A., Yin, M., Fidler, J. L., Sanderson, S. O., Kamath, P. S., & Ehman, R. L. (2008) · Hepatology · doi:10.1002/hep.21972 · Cited by 314
Self-citationMeasuring the elastic modulus of ex vivo small tissue samples
Samani, A., Bishop, J., Luginbuhl, C., & Plewes, D. B. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/14/310 · Cited by 295
Assessment of liver viscoelasticity using multifrequency MR elastography
Asbach, P., Klatt, D., Hamhaber, U., Braun, J., Somasundaram, R., Hamm, B., & Sack, I. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21636 · Cited by 264
Mechanics of the normal woman's breast
Gefen, A., & Dilmoney, B. (2007) · Technology and Health Care · doi:10.3233/thc-2007-15404 · Cited by 257
Review of MR elastography applications and recent developments
Glaser, K. J., Manduca, A., & Ehman, R. L. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23597 · Cited by 245
“5), variations in stiffness between different muscles (136,137), and anisotropic stiffness in ex vivo bovine muscle tissue (44).”
BackgroundSelf-citationRogowska, J., Patel, N. A., Fujimoto, J. G., & Brezinski, M. E. (2004) · Heart · doi:10.1136/hrt.2003.016956 · Cited by 233
Initial in vivo experience with steady‐state subzone‐based MR elastography of the human breast
Van Houten, E. E. W., Doyley, M. M., Kennedy, F. E., Weaver, J. B., & Paulsen, K. D. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10232 · Cited by 224
Acoustic Waves in Medical Imaging and Diagnostics
Sarvazyan, A. P., Urban, M. W., & Greenleaf, J. F. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.02.006 · Cited by 223
“Multiple groups have examined the dispersion of shear waves in various soft tissues (Yamakoshi et al. 1990; Kruse et al. 2000; Kanai 2005; Klatt et al. 2007; Asbach et al. 2008; Tanter et al. 2008; Chen et al. 2009; Deffieux et al. 2009; Muller et al. 2009; Urban and Greenleaf 2009; Asbach et al.…”
BackgroundMethodSelf-citationKandlikar, S. G., Perez-Raya, I., Raghupathi, P. A., Gonzalez-Hernandez, J.-L., Dabydeen, D., Medeiros, L., & Phatak, P. (2017) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.01.086 · Cited by 208
Talwalkar, J. A., Yin, M., Venkatesh, S., Rossman, P. J., Grimm, R. C., Manduca, A., Romano, A., Kamath, P. S., & Ehman, R. L. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.07.3504 · Cited by 198
“To obtain a consistent position of the liver and spleen for each phase offset, individual subjects were asked to hold their breath at the end of expiration [14, 18, 19].”
BackgroundSelf-citationMechanical transient‐based magnetic resonance elastography
McCracken, P. J., Manduca, A., Felmlee, J., & Ehman, R. L. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20388 · Cited by 175
“To date, most work in dynamic MRE has focused on the use of harmonic (1,6,7) or steady-state (8,9) mechanical excitation.”
BackgroundMethodSelf-citation
Metadata
- Authors
- Kruse, S. A., Smith, J. A., Lawrence, A. J., Dresner, M. A., Manduca, A., Greenleaf, J. F., Ehman, R. L., Kruse, S. A., Smith, J. A., Lawrence, A. J., Dresner, M. A., Manduca, A., & Greenleaf, J. F.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2000-05-19
- Volume
- 45
- Issue
- 6
- Pages
- 1579-1590
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2103232886
- Cited by
- 340
- References
- 15
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.