Medical image registration
The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
Abstract
Radiological images are increasingly being used in healthcare and medical research. There is, consequently, widespread interest in accurately relating information in the different images for diagnosis, treatment and basic science. This article reviews registration techniques used to solve this problem, and describes the wide variety of applications to which these techniques are applied. Applications of image registration include combining images of the same subject from different modalities, aligning temporal sequences of images to compensate for motion of the subject between scans, image guidance during interventions and aligning images from multiple subjects in cohort studies. Current registration algorithms can, in many cases, automatically register images that are related by a rigid body transformation (i.e. where tissue deformation can be ignored). There has also been substantial progress in non-rigid registration algorithms that can compensate for tissue deformation, or align images from different subjects. Nevertheless many registration problems remain unsolved, and this is likely to continue to be an active field of research in the future.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“General approaches address multimodal image registration by either performing image synthesis [22, 23] to change the problem to a uni-modal image registration task, or by proposing complex, hand-crafted [24, 25, 26, 27] or learned [28, 29, 30, 31, 32] multi-modal image similarity measures.”
From Quicksilver: Fast predictive image registration – A deep learning approach (2017) · cites this paper as [29]
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Co-Planar Stereotaxic Atlas of the Human Brain
Talairach, J., & Tournoux, P. (1988) · Medical Entomology and Zoology · Cited by 11,798
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Golub, G. H., & Loan, C. F. V. (1996) · Johns Hopkins University Press eBooks · Cited by 6,027
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationPrincipal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Communication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,804
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 4,028
Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
The Geometry of Algorithms with Orthogonality Constraints
Edelman, A., Arias, T. A., & Smith, S. T. (1998) · SIAM Journal on Matrix Analysis and Applications · doi:10.1137/s0895479895290954 · Cited by 2,685
Mathematical Foundations of Elasticity
Marsden, J. E., Hughes, T. J. R., & Carlson, D. E. (1984) · Journal of Applied Mechanics · doi:10.1115/1.3167757 · Cited by 2,665
Alignment by Maximization of Mutual Information
Viola, P., & Wells III, W. M. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007958904918 · Cited by 2,610
Least-squares estimation of transformation parameters between two point patterns
Umeyama, S. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.88573 · Cited by 2,420
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Self-citationA Generalized Solution of the Orthogonal Procrustes Problem
Schönemann, P. H. (1966) · Psychometrika · doi:10.1007/bf02289451 · Cited by 2,040
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959
Rapid Automated Algorithm for Aligning and Reslicing PET Images
Woods, R. P., Cherry, S. R., & Mazziotta, J. C. (1992) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199207000-00024 · Cited by 1,912
Nonlinear spatial normalization using basis functions
Ashburner, J., & Friston, K. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)7:4<254::aid-hbm4>3.0.co;2-g · Cited by 1,884
Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707
Splines: a perfect fit for signal and image processing
Unser, M. (1999) · IEEE Signal Processing Magazine · doi:10.1109/79.799930 · Cited by 1,633
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Correction for geometric distortion in echo planar images from B 0 field variations
Jezzard, P., & Balaban, R. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340111 · Cited by 1,421
Survey: interpolation methods in medical image processing
Lehmann, T. M., Gonner, C., & Spitzer, K. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.816070 · Cited by 1,340
Numerical recipes in C (2nd ed.): the art of scientific computing
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1992) · Cambridge University Press eBooks · Cited by 1,156
Deformable templates using large deformation kinematics
Christensen, G. E., Rabbitt, R. D., & Miller, M. I. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.536892 · Cited by 1,142
Accurate Three-Dimensional Registration of CT, PET, and/or MR Images of the Brain
Pelizzari, C. A., Chen, G. T. Y., Spelbring, D. R., Weichselbaum, R. R., & Chen, C.-T. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198901000-00004 · Cited by 1,096
Predicting error in rigid-body point-based registration
Fitzpatrick, J. M., West, J. B., & Maurer, C. R. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736021 · Cited by 1,010
Automated Image Registration: II. Intersubject Validation of Linear and Nonlinear Models
Woods, R. P., Grafton, S. T., Watson, J. D. G., Sicotte, N. L., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00028 · Cited by 994
On the Early History of the Singular Value Decomposition
Stewart, G. W. (1993) · SIAM Review · doi:10.1137/1035134 · Cited by 985
Automatic 3‐D model‐based neuroanatomical segmentation
Collins, D. L., Holmes, C. J., Peters, T. M., & Evans, A. C. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030304 · Cited by 974
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Self-citationGrowth patterns in the developing brain detected by using continuum mechanical tensor maps
Thompson, P. M., Giedd, J. N., Woods, R. P., MacDonald, D., Evans, A. C., & Toga, A. W. (2000) · Nature · doi:10.1038/35004593 · Cited by 850
Comparison of Interpolating Methods for Image Resampling
Parker, J. A., Kenyon, R. V., & Troxel, D. E. (1983) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1983.4307610 · Cited by 829
A comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
Self-citationDistance transformations in arbitrary dimensions
Borgefors, G. (1984) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(84)90035-5 · Cited by 779
Interpolation using surface splines.
HARDER, R. L., & DESMARAIS, R. N. (1972) · Journal of Aircraft · doi:10.2514/3.44330 · Cited by 770
Medical image matching-a review with classification
van den Elsen, P. A., Pol, E.-J. D., & Viergever, M. A. (1993) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.195938 · Cited by 718
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1997) · Medical Physics · doi:10.1118/1.598130 · Cited by 675
Self-citationReal-time 3D image registration for functional MRI
Cox, R. W., & Jesmanowicz, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1014::aid-mrm4>3.0.co;2-f · Cited by 663
A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope
Roberts, D. W., Strohbehn, J. W., Hatch, J. F., Murray, W. T., & Kettenberger, H. (1986) · Journal of neurosurgery · doi:10.3171/jns.1986.65.4.0545 · Cited by 640
Registration of head volume images using implantable fiducial markers
Maurer, C. R., Fitzpatrick, J. M., Wang, M. Y., Galloway, R. L., Maciunas, R. J., & Allen, G. S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.611354 · Cited by 561
A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
Chang, H., & Fitzpatrick, J. M. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.158935 · Cited by 425
Automated 3-D registration of MR and CT images of the head
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80011-9 · Cited by 374
Self-citationThe procrustes program: Producing direct rotation to test a hypothesized factor structure
Hurley, J. R., & Cattell, R. B. (2007) · Behavioral Science · doi:10.1002/bs.3830070216 · Cited by 347
Estimating the bias field of MR images
Guillemaud, R., & Brady, M. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.585758 · Cited by 329
Whittaker, J. M. (1935) · Cited by 326
Grimson, W. E. L., Ettinger, G. J., White, S. J., Lozano-Perez, T., Wells, W. M., & Kikinis, R. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491415 · Cited by 316
Gene recognition via spliced sequence alignment.
Gelfand, M. S., Mironov, A. A., & Pevzner, P. A. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.17.9061 · Cited by 307
A Registration and Interpolation Procedure for Subvoxel Matching of Serially Acquired MR Images
Hajnal, J. V., Saeed, N., Soar, E. J., Oatridge, A., Young, I. R., & Bydder, G. M. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199503000-00022 · Cited by 304
Voxel similarity measures for 3-D serial MR brain image registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836369 · Cited by 277
Self-citationInterpolation Artefacts in Mutual Information-Based Image Registration
Pluim, J. P. W., Antoine Maintz, J. B., & Viergever, M. A. (2000) · Computer Vision and Image Understanding · doi:10.1006/cviu.1999.0816 · Cited by 255
Multi-modality image registration by maximization of mutual information
Maes, F., Vandermeulen, D., & Suetens, P. L. (2000) · Cited by 255
Voxel Similarity Measures for 3D Serial MR Brain Image Registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., & Hawkes, D. J. (1999) · Lecture Notes in Computer Science · doi:10.1007/3-540-48714-x_48 · Cited by 246
Self-citationAutomatic three‐dimensional correlation of CT‐CT, CT‐MRI, and CT‐SPECT using chamfer matching
van Herk, M., & Kooy, H. M. (1994) · Medical Physics · doi:10.1118/1.597344 · Cited by 246
Lavallee, S., & Szeliski, R. (1995) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.385980 · Cited by 242
The Orthogonal Approximation of an Oblique Structure in Factor Analysis
Green, B. F. (1952) · Psychometrika · doi:10.1007/bf02288918 · Cited by 234
Evans, A. C., Beil, C., Marrett, S., Thompson, C. J., & Hakim, A. (1988) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1988.92 · Cited by 232
Lemieux, L., Jagoe, R., Fish, D. R., Kitchen, N. D., & Thomas, D. G. T. (1994) · Medical Physics · doi:10.1118/1.597276 · Cited by 222
Dawant, B. M., Hartmann, S. L., Thirion, J.-P., Maes, F., Vandermeulen, D., & Demaerel, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811271 · Cited by 217
Registration of images with geometric distortions
Goshtasby, A. (1988) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/36.3000 · Cited by 209
THE ORTHOGONAL APPROXIMATION OF AN OBLIQUE STRUCTURE IN FACTOR ANALYSIS
Green, B. F. (1951) · ETS Research Bulletin Series · doi:10.1002/j.2333-8504.1951.tb00218.x · Cited by 205
Design and evaluation of a system for microscope-assisted guided interventions (MAGI)
Edwards, P. J., King, A. P., Maurer, C. R., De Cunha, D. A., Hawkes, D. J., Hill, D. L. G., Gaston, R. P., Fenlon, M. R., Jusczyzck, A., Strong, A. J., et al. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896784 · Cited by 204
Self-citationRetrospective geometric correlation of MR, CT, and PET images.
Levin, D. N., Pelizzari, C. A., Chen, G. T., Chen, C. T., & Cooper, M. D. (1988) · Radiology · doi:10.1148/radiology.169.3.3263666 · Cited by 200
Registration of MR and CT images for skull base surgery using point-like anatomical features
Hill, D. L. G., Hawkes, D. J., Crossman, J. E., Gleeson, M. J., Cox, T. C. S., Bracey, E. E. C. M. L., Strong, A. J., & Graves, P. (1991) · The British Journal of Radiology · doi:10.1259/0007-1285-64-767-1030 · Cited by 198
Self-citationAnalysis of 3-D rotation fitting
Kanatani, K. (1994) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.291441 · Cited by 196
Studies in the Robustness of Multidimensional Scaling: Procrustes Statistics
Sibson, R. (1978) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1978.tb01669.x · Cited by 195
Deformations Incorporating Rigid Structures
Little, J. A., Hill, D. L. G., & Hawkes, D. J. (1997) · Computer Vision and Image Understanding · doi:10.1006/cviu.1997.0608 · Cited by 193
Self-citationUsing Partial Derivatives of 3D Images to Extract Typical Surface Features
Monga, O., & Benayoun, S. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1014 · Cited by 189
Evaluation of ridge seeking operators for multimodality medical image matching
Maintz, J. B. A., van den Elsen, P. A., & Viergever, M. A. (1996) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.491617 · Cited by 189
A Framework for Uncertainty and Validation of 3-D Registration Methods Based on Points and Frames
Xavier Pennec, B., & Thirion, J. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007976002485 · Cited by 178
A review of medical image registration
Ma, B. (1999) · Information of Medical Equipment · Cited by 173
Schad, L. R., Boesecke, R., Schlegel, W., Hartmann, G. H., Sturm, V., Strauss, L. G., & Lorenz, W. J. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198711000-00005 · Cited by 170
Voxel-based 2-D/3-D registration of fluoroscopy images and CT scans for image-guided surgery
Weese, J., Penney, G. P., Desmedt, P., Buzug, T. M., Hill, D. L. G., & Hawkes, D. J. (1997) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.681173 · Cited by 164
Self-citationMaurer, C. R., Maciunas, R. J., & Fitzpatrick, J. M. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736031 · Cited by 163
New approach to 3-D registration of multimodality medical images by surface matching:
Jiang, H., Robb, R. A., & Holton Tainter, K. S. (1992) · SPIE Proceedings · doi:10.1117/12.131078 · Cited by 162
Freeborough, P. A., Woods, R. P., & Fox, N. C. (1996) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199611000-00030 · Cited by 158
Visual assessment of the accuracy of retrospective registration of MR and CT images of the brain
Fitzpatrick, J. M., Hill, D., Shyr, Y., West, J. B., Studholme, C., & Maurer, C. R. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730402 · Cited by 157
Self-citationDetection of Subtle Brain Changes Using Subvoxel Registration and Subtraction of Serial MR Images
Hajnal, J. V., Saeed, N., Oatridge, A., Williams, E. J., Young, I. R., & Bydder, G. M. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199509000-00001 · Cited by 154
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., KESSLER, R. M., & Maciunas, R. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.759119 · Cited by 150
Voxel similarity measures for automated image registration
Hill, D., Studholme, C., & Hawkes, D. J. (1994) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.185180 · Cited by 149
Self-citationLemieux, L., Wieshmann, U. C., Moran, N. F., Fish, D. R., & Shorvon, S. D. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80021-2 · Cited by 149
Smoothing and matching of 3-d space curves
Gu�ziec, A., & Ayache, N. (1994) · International Journal of Computer Vision · doi:10.1007/bf01420985 · Cited by 143
Improved image registration by using fourier interpolation
Eddyy, W. F., Fitzgerald, M., & Noll, D. C. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360615 · Cited by 142
Automatic registration of CT and MR brain images using correlation of geometrical features
van den Elsen, P. A., Maintz, J. B. A., Pol, E.-J. D., & Viergever, M. A. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.387719 · Cited by 142
Applebaum, D. (2008) · Cambridge University Press eBooks · doi:10.1017/cbo9780511755262 · Cited by 133
Atkinson, D., Porter, D. A., Hill, D., Calamante, F., & Connelly, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<101::aid-mrm15>3.0.co;2-s · Cited by 127
Self-citationAutomatic compensation of motion artifacts in MRI
Atkinson, D., Hill, D. L. G., Stoyle, P. N. R., Summers, P. E., Clare, S., Bowtell, R., & Keevil, S. F. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199901)41:1<163::aid-mrm23>3.0.co;2-9 · Cited by 122
Self-citationQuantifying MRI geometric distortion in tissue
Sumanaweera, T. S., Glover, G. H., Song, S. M.-H., Adler, J. R., & Napel, S. A. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310106 · Cited by 120
A Euclidean distance transform using grayscale morphology decomposition
Huang, C. T., & Mitchell, O. R. (1994) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.277600 · Cited by 106
Declerck, J. M., Feldmar, J., Goris, M. L., & Betting, F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650870 · Cited by 102
Integrated stereotaxic imaging with CT, MR imaging, and digital subtraction angiography.
Peters, T. M., Clark, J. A., Olivier, A., Marchand, E. P., Mawko, G., Dieumegarde, M., Muresan, L., & Ethier, R. (1986) · Radiology · doi:10.1148/radiology.161.3.3538140 · Cited by 101
Diffusion‐weighted multiple shot echo planar imaging of humans without navigation
Robson, M. D., Anderson, A. W., & Gore, J. C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380113 · Cited by 99
Ultra High Resolution Imaging of the Human Head at 8 Tesla: 2K × 2K for Y2K
Robitaille, P.-M. L., Abduljalil, A., & Kangarlu, A. (2000) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200001000-00002 · Cited by 99
Colchester, A. C. F., Zhao, J. C., Tainter, K. S. H., Henri, C. J., Maitland, N., Roberts, P. T. E., Harris, C. G., & Evans, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80006-2 · Cited by 90
Orientation of 3-D structures in medical images
Faber, T. L., & Stokely, E. M. (1988) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.6771 · Cited by 86
Tan, K. K., Grzeszczuk, R. P., Levin, D. N., Pelizzari, C. A., Chen, G. T. Y., Erickson, R. K., Johnson, D., & Dohrmann, G. J. (1993) · Journal of neurosurgery · doi:10.3171/jns.1993.79.2.0296 · Cited by 81
A Weighted Procrustes Criterion
Koschat, M. A., & Swayne, D. F. (1991) · Psychometrika · doi:10.1007/bf02294460 · Cited by 77
Grey value correlation techniques used for automatic matching of CT and MR brain and spine images:
van den Elsen, P. A., Pol, E.-J. D., Sumanaweera, T. S., Hemler, P. F., Napel, S., & Adler, J. R. (1994) · SPIE Proceedings · doi:10.1117/12.185182 · Cited by 73
Registration of head volume images using implantable fiducial markers
Maurer, C. R., Fitzpatrick, J. M., Wang, M. Y., Galloway, R. L., Maciunas, R. J., & Allen, G. S. (1997) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.274143 · Cited by 73
Medical image registration using geometric hashing
Gueziec, A. P., Pennec, X., & Ayache, N. (1997) · IEEE Computational Science and Engineering · doi:10.1109/99.641607 · Cited by 68
Spatial and temporal registration of cardiac SPECT and MR images: methods and evaluation.
Faber, T. L., McColl, R. W., Opperman, R., Corbett, J. R., & Peshock, R. M. (1991) · Radiology · doi:10.1148/radiology.179.3.2028006 · Cited by 66
Voxel‐based localization in frame‐based and frameless stereotaxy and its accuracy
Lemieux, L., Kitchen, N. D., Hughes, S., & Thomas, D. G. T. (1994) · Medical Physics · doi:10.1118/1.597403 · Cited by 66
Anatomical Localization for PET Using MR Imaging
MELTZER, C. C., Bryan, R. N., Holcomb, H. H., Kimball, A. W., Mayberg, H. S., Sadzot, B., Leal, J. P., Wagner, H. N., & Frost, J. J. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199005000-00019 · Cited by 58
Hauser, R. E., Westermann, B., & Probst, R. R. (1997) · The Laryngoscope · doi:10.1097/00005537-199704000-00012 · Cited by 54
Hill, D., Maurer, C. R., Studholme, C., Fitzpatrick, J. M., & Hawkes, D. J. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199803000-00031 · Cited by 49
Self-citationRegistration in neurosurgery and neuroradiotherapy applications
Cuchet, E., Knoplioch, J., Dormont, D., & Marsault, C. (1995) · Journal of Image Guided Surgery · Cited by 44
Correlation Methods for Tomographic Images Using Two and Three Dimensional Techniques
Maguire, G. Q., Noz, M. E., Lee, E. M., & Schimpf, J. H. (1986) · Information Processing in Medical Imaging · doi:10.1007/978-94-009-4261-5_20 · Cited by 42
A noninvasive, reattachable skull fiducial marker system
Howard, M. A., Dobbs, M. B., Simonson, T. M., LaVelle, W. E., & Granner, M. A. (1995) · Journal of neurosurgery · doi:10.3171/jns.1995.83.2.0372 · Cited by 40
Denton, E., Holden, M. P., Christ, E., Jarosz, J., Russell-Jones, D. L., Goodey, J., Cox, T. C. S., & Hill, D. (2000) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200001000-00025 · Cited by 32
Self-citationLemieux, L., & Barker, G. J. (1998) · Medical Physics · doi:10.1118/1.598288 · Cited by 32
Image registration for DSA quality enhancement
Buzug, T. M., & Weese, J. (1998) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(98)00012-3 · Cited by 31
Improved quality of re-sliced MR images using re-normalized sinc interpolation
Thacker, N. A., Jackson, A., Moriarty, D., & Vokurka, E. A. (1999) · Journal of Magnetic Resonance Imaging · Cited by 31
Bayesian Estimation of Intra-operative Deformation for Image-Guided Surgery Using 3-D Ultrasound
King, A. P., Blackall, J. M., Penney, G., Edwards, P., Hill, D., & Hawkes, D. J. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_60 · Cited by 28
Self-citationLocking acrylic resin dental stent for image-guided surgery
Fenlon, M. R., Jusczyzck, A. S., Edwards, P., & King, A. P. (2000) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(00)70047-3 · Cited by 23
Geometry driven multimodality matching of brain images
van den Elsen, P. A., Maintz, J. B. A., & Viergever, M. A. (1992) · Brain Topography · doi:10.1007/bf01129043 · Cited by 22
Rapid autocorrection using prescan navigator echoes
McGee, K. P., Felmlee, J. P., Manduca, A., Riederer, S. J., & Ehman, R. L. (2000) · Magnetic Resonance in Medicine · Cited by 20
Perturbation analysis of the orthogonal procrustes problem
Söderkvist, I. (1993) · BIT Numerical Mathematics · doi:10.1007/bf01990543 · Cited by 18
Registration of multiple video images to preoperative CT for image-guided surgery
Clarkson, M. J., Rueckert, D., Hill, D., & Hawkes, D. J. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.348487 · Cited by 13
Self-citationMultiple 2D video/3D medical image registration algorithm
Clarkson, M. J., Rueckert, D., Hill, D., & Hawkes, D. J. (2000) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.387696 · Cited by 7
Self-citation
Research works printed but not linked: 7
- 10.1016/S1361-8415(96)80006-5 · doi:10.1016/s1361-8415(96)80006-5
- 10.1002/(SICI)1522-712X(1995)1:4<198::AID-IGS2>3.0.CO;2-5 · doi:10.1002/(sici)1522-712x(1995)1:4<198::aid-igs2>3.0.co;2-5
- 10.1002/(SICI)1522-2594(200004)43:4<583::AID-MRM13>3.0.CO;2-B · doi:10.1002/(sici)1522-2594(200004)43:4<583::aid-mrm13>3.0.co;2-b
- Press W H, 1992
- Sibson R, 1978, J. R. Statist. Soc., 40, 234
- 10.1002/(SICI)1522-2586(199910)10:4<582::AID-JMRI12>3.0.CO;2-X · doi:10.1002/(sici)1522-2586(199910)10:4<582::aid-jmri12>3.0.co;2-x
- 10.1016/S1361-8415(96)80004-1 · doi:10.1016/s1361-8415(96)80004-1
Cited by
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
The Alzheimer’s disease neuroimaging initiative (ADNI): MRI methods
Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P., Alexander, G., Harvey, D., Borowski, B., Britson, P. J., L. Whitwell, J., Ward, C., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21049 · Cited by 4,347
Self-citationElastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
Metadata
- Authors
- Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J.
- Affiliations
- Guy's Hospital (GB)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-02-15
- Volume
- 46
- Issue
- 3
- Pages
- R1-R45
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2140139548
- Cited by
- 2,093
- References
- 127
- Citations by year
- 2026: 19 · 2025: 21 · 2024: 40 · 2023: 47 · 2022: 45 · 2021: 44 · 2020: 53 · 2019: 57 · 2018: 66 · 2017: 89 · 2016: 69 · 2015: 100 · 2014: 104 · 2013: 124 · 2012: 105
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Research Portal (King's College London) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- medical image registration, multimodal image fusion, motion compensation, image-guided interventions, rigid transformation, non-rigid registration, tissue deformation, temporal image sequences
- MeSH terms
- Algorithms, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted, Registries, Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.