Medical image registration
The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
Abstract
Radiological images are increasingly being used in healthcare and medical research. There is, consequently, widespread interest in accurately relating information in the different images for diagnosis, treatment and basic science. This article reviews registration techniques used to solve this problem, and describes the wide variety of applications to which these techniques are applied. Applications of image registration include combining images of the same subject from different modalities, aligning temporal sequences of images to compensate for motion of the subject between scans, image guidance during interventions and aligning images from multiple subjects in cohort studies. Current registration algorithms can, in many cases, automatically register images that are related by a rigid body transformation (i.e. where tissue deformation can be ignored). There has also been substantial progress in non-rigid registration algorithms that can compensate for tissue deformation, or align images from different subjects. Nevertheless many registration problems remain unsolved, and this is likely to continue to be an active field of research in the future.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“General approaches address multimodal image registration by either performing image synthesis [22, 23] to change the problem to a uni-modal image registration task, or by proposing complex, hand-crafted [24, 25, 26, 27] or learned [28, 29, 30, 31, 32] multi-modal image similarity measures.”
From Quicksilver: Fast predictive image registration – A deep learning approach (2017) · cites this paper as [29]
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Co-Planar Stereotaxic Atlas of the Human Brain
Talairach, J., & Tournoux, P. (1988) · Medical Entomology and Zoology · Cited by 11,798
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Golub, G. H., & Loan, C. F. V. (1996) · Johns Hopkins University Press eBooks · Cited by 6,027
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationPrincipal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Communication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,804
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Research works printed but not linked: 7
- 10.1016/S1361-8415(96)80006-5 · doi:10.1016/s1361-8415(96)80006-5
- 10.1002/(SICI)1522-712X(1995)1:4<198::AID-IGS2>3.0.CO;2-5 · doi:10.1002/(sici)1522-712x(1995)1:4<198::aid-igs2>3.0.co;2-5
- 10.1002/(SICI)1522-2594(200004)43:4<583::AID-MRM13>3.0.CO;2-B · doi:10.1002/(sici)1522-2594(200004)43:4<583::aid-mrm13>3.0.co;2-b
- Press W H, 1992
- Sibson R, 1978, J. R. Statist. Soc., 40, 234
- 10.1002/(SICI)1522-2586(199910)10:4<582::AID-JMRI12>3.0.CO;2-X · doi:10.1002/(sici)1522-2586(199910)10:4<582::aid-jmri12>3.0.co;2-x
- 10.1016/S1361-8415(96)80004-1 · doi:10.1016/s1361-8415(96)80004-1
Cited by
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
The Alzheimer’s disease neuroimaging initiative (ADNI): MRI methods
Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P., Alexander, G., Harvey, D., Borowski, B., Britson, P. J., L. Whitwell, J., Ward, C., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21049 · Cited by 4,347
Self-citationElastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
Highly accurate inverse consistent registration: A robust approach
Reuter, M., Rosas, H. D., & Fischl, B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.020 · Cited by 1,388
A Review of Indocyanine Green Fluorescent Imaging in Surgery
Alander, J. T., Kaartinen, I., Laakso, A., Pätilä, T., Spillmann, T., Tuchin, V. V., Venermo, M., & Välisuo, P. (2012) · International Journal of Biomedical Imaging · doi:10.1155/2012/940585 · Cited by 1,352
Survey of Medical Image Registration
Mani, V., & rivazhagan, D. S. (2013) · Journal of biomedical engineering and technology · doi:10.12691/jbet-1-2-1 · Cited by 96
“Clearly most of the human body does not conform to a rigid or even an affine approximation [1] and much of the most interesting work in registration today involves the development of non-rigid registration techniques for applications ranging from modeling, tissue deformations to variability in anatomical structures, N…”
BackgroundMethodInfluentialCuingnet, R., Gerardin, E., Tessieras, J., Auzias, G., Lehéricy, S., Habert, M.-O., Chupin, M., Benali, H., & Colliot, O. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.013 · Cited by 959
“The image geometry correction was the 3D gradwarp correction (Hajnal et al., 2001; Jovicich et al. 2006). The B1 non-uniformity correction is detailed inNarayana et al. (1988). These twopreprocessing steps can be performed directly on the MRI console and thus seem feasible in clinical routine.”
Long-Lived Emissive Probes for Time-Resolved Photoluminescence Bioimaging and Biosensing
Zhang, K. Y., Yu, Q., Wei, H., Liu, S., Zhao, Q., & Huang, W. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00425 · Cited by 923
Brock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881
Mitra, P., & Bokil, H. (2007) · doi:10.1093/acprof:oso/9780195178081.001.0001 · Cited by 842
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
“SPECT images, registration has also been useful for correct scatter attenuation and partial volume corrections based on CT images (Bai and Brady, 2011; Hajnal et al., 2001).”
BackgroundMethodA Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
Non-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
Self-citationDeep learning in medical image registration: a survey
Haskins, G., Kruger, U., & Yan, P. (2020) · Machine Vision and Applications · doi:10.1007/s00138-020-01060-x · Cited by 704
Machine learning and radiology
Wang, S., & Summers, R. M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.02.005 · Cited by 697
RIFT: Multi-Modal Image Matching Based on Radiation-Variation Insensitive Feature Transform
Li, J., Hu, Q., & Ai, M. (2020) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2959244 · Cited by 651
Castillo, R., Castillo, E., Guerra, R., Johnson, V. E., McPhail, T., Garg, A. K., & Guerrero, T. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/7/001 · Cited by 592
Quicksilver: Fast predictive image registration – A deep learning approach
Yang, X., Kwitt, R., Styner, M., & Niethammer, M. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.008 · Cited by 630
“x). Here, ddenotes the spatial dimension and xis the spatial coordinate of the xed target image T.Due to the importance of image registration, a large number of dierent approaches have been proposed [1,37,38,39]. Typically, these approaches are formulated as optimization problems, where one seeks to minimize an energy…”
BackgroundLee, W., Debasitis, J. C., Lee, V. K., Lee, J.-H., Fischer, K., Edminster, K., Park, J.-K., & Yoo, S.-S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.009 · Cited by 578
Rohlfing, T., Maurer, C. R., Bluemke, D. A., & Jacobs, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.814791 · Cited by 445
4-dimensional computed tomography imaging and treatment planning
KEALL, P. (2004) · Seminars in Radiation Oncology · doi:10.1053/j.semradonc.2003.10.006 · Cited by 484
Dense image registration through MRFs and efficient linear programming
Glocker, B., Komodakis, N., Tziritas, G., Navab, N., & Paragios, N. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.03.006 · Cited by 427
“Our framework currently contains a range of well-known similarity measures, namely the sum of absolute differences (SAD), the sum of squared differences (SSD), the normalized cross correlation (NCC) (Hajnal et al., 2001), the normalized mutual information (NMI) (Maes et al.”
BackgroundA review of atlas-based segmentation for magnetic resonance brain images
Cabezas, M., Oliver, A., Lladó, X., Freixenet, J., & Bach Cuadra, M. (2011) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2011.07.015 · Cited by 416
“[11] D.”
BackgroundRobust Feature Matching for Remote Sensing Image Registration via Locally Linear Transforming
Ma, J., Zhou, H., Zhao, J., Gao, Y., Jiang, J., & Tian, J. (2015) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2015.2441954 · Cited by 474
Image-Guided Interventions: Technology Review and Clinical Applications
Cleary, K., & Peters, T. M. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105249 · Cited by 453
Weakly-supervised convolutional neural networks for multimodal image registration
Hu, Y., Modat, M., Gibson, E., Li, W., Ghavami, N., Bonmati, E., Wang, G., Bandula, S., Moore, C. M., Emberton, M., et al. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.07.002 · Cited by 458
“Classical pairwise intensity-based image registration methods are in general based on optimising image similarity, a metric indicating how well image intensities correspond (Hill et al., 2001).”
BackgroundSchnabel, J. A., Rueckert, D., Quist, M., Blackall, J. M., Castellano-Smith, A. D., Hartkens, T., Penney, G. P., Hall, W. A., Liu, H., Truwit, C. L., et al. (2001) · Lecture Notes in Computer Science · doi:10.1007/3-540-45468-3_69 · Cited by 355
“Even though there is a large number of registration methods to be found in the literature [2,3], existing methods have usually been designed for or fine-tuned to specific, mostly single-modality applications.”
BackgroundSelf-citationEvaluation of Registration Methods on Thoracic CT: The EMPIRE10 Challenge
Murphy, K., van Ginneken, B., Reinhardt, J. M., Kabus, S., Ding, K., Deng, X., Cao, K., Du, K., Christensen, G. E., Garcia, V., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2158349 · Cited by 440
The dual-bootstrap iterative closest point algorithm with application to retinal image registration
Stewart, C. V., Tsai, C.-L., & Roysam, B. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819276 · Cited by 346
Handbook of Mathematical Methods in Imaging
Scherzer, O. (2015) · Handbook of Mathematical Methods in Imaging · doi:10.1007/978-1-4939-0790-8 · Cited by 427
Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y.-D., Dong, Z., Wang, S.-H., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramirez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 453
“It aims at determining the spatial alignment between images of the same or different subjects by means of optimizing a cost function, which measures the similarity between the transformed input image and the reference image (template) [315] .”
DRAMMS: Deformable registration via attribute matching and mutual-saliency weighting
Ou, Y., Sotiras, A., Paragios, N., & Davatzikos, C. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.07.002 · Cited by 407
DRAMMS: Deformable Registration via Attribute Matching and Mutual-Saliency Weighting
Ou, Y., & Davatzikos, C. A. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02498-6_5 · Cited by 34
An Approach to Multimodal Biomedical Image Registration Utilizing Particle Swarm Optimization
Wachowiak, M. P., Smolikova, R., Zheng, Y., Zurada, J. M., & Elmaghraby, A. S. (2004) · IEEE Transactions on Evolutionary Computation · doi:10.1109/tevc.2004.826068 · Cited by 389
Consistent and Elastic Registration of Histological Sections Using Vector-Spline Regularization
Arganda-Carreras, I., Sorzano, C. O. S., Marabini, R., Carazo, J. M., Ortiz-de-Solorzano, C., & Kybic, J. (2006) · Lecture Notes in Computer Science · doi:10.1007/11889762_8 · Cited by 325
A Review of Geometric Transformations for Nonrigid Body Registration
Holden, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.904691 · Cited by 369
Self-citationIn vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
“Cross-modality imaging with subsequent image registration using software approaches has been studied for many years (Hill et al 2001), and is extensively used for studies of the human brain where function as measured by PET or SPECT is accurately mapped onto the anatomy usually provided by MRI.”
A review of cardiac image registration methods
Makela, T., Clarysse, P., Sipila, O., Pauna, N., Pham, Q. C., Katila, T., & Magnin, I. E. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804441 · Cited by 361
What is the best similarity measure for motion correction in fMRI time series?
Freire, L., Roche, A., & Mangin, J.-F. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009383 · Cited by 353
Handbook of Mathematical Methods in Imaging
(2011) · Springer eBooks · doi:10.1007/978-0-387-92920-0 · Cited by 334
Motion in radiotherapy: particle therapy
Bert, C., & Durante, M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/16/r01 · Cited by 315
“Several algorithms and implementations are reported in the literature and are commercially available (Brock et al 2006, Hill et al 2001, Kessler 2006, Rietzel and Chen 2006, Sarrut 2006, Wang et al 2005, Yang et al 2008).”
MethodConstruction of an abdominal probabilistic atlas and its application in segmentation
Park, H., Bland, P. H., & Meyer, C. R. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809139 · Cited by 328
Motion Correction Algorithms May Create Spurious Brain Activations in the Absence of Subject Motion
Freire, L., & Mangin, J.-F. (2001) · NeuroImage · doi:10.1006/nimg.2001.0869 · Cited by 308
“While this choice allows rapid minimization of the measure iteratively using a singular value decomposition (SVD), it may explain some differences with other implementations of the same similarity measure (Hill et al., 2001).”
BackgroundMethodInfluentialMR diffusion tensor imaging: recent advance and new techniques for diffusion tensor visualization
Masutani, Y., Aoki, S., Abe, O., Hayashi, N., & Otomo, K. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00328-5 · Cited by 309
Intensity-Based Image Registration by Minimizing Residual Complexity
Myronenko, A., & Song, X. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053043 · Cited by 325
A Partial Intensity Invariant Feature Descriptor for Multimodal Retinal Image Registration
Chen, J., Tian, J., Lee, N., Zheng, J., Smith, R. T., & Laine, A. F. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2042169 · Cited by 311
Brain shift in neuronavigation of brain tumors: A review
Gerard, I. J., Kersten-Oertel, M., Petrecca, K., Sirhan, D., Hall, J. A., & Collins, D. L. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.08.007 · Cited by 324
“As the details of registration methods re not intended to be the focus of this review interested readrs are directed to Hill et al. (2001) , Maintz and Viergever (1998) , nd Oliveira and Tavares (2014) for a general overview and perpective of medical image registration, to Sotiras et al. (2013)…”
MethodFast free-form deformable registration via calculus of variations
Lu, W., Chen, M.-L., Olivera, G. H., Ruchala, K. J., & Mackie, T. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/003 · Cited by 259
“Recent reviews have appeared in several journal publications (Brown 1992, van den Elsen et al 1993, Maintz and Viergever 1998, Hill et al 2001, Zitova and Flusser 2003) and books (Hajnal et al 2001, Gee et al 2003).”
Image-guidance for surgical procedures
Peters, T. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/14/r01 · Cited by 249
“To achieve this latter aim, the video image produced by the endoscope may be mapped onto an interior surface model explored by the endoscope (Dey et al 2002). A similar approach has been described by Szpala et al (2005) for registering endoscopic images with pre-operatively acquired dynamic models of the beating heart.”
MethodAutomated electrocorticographic electrode localization on individually rendered brain surfaces
Hermes, D., Miller, K. J., Noordmans, H. J., Vansteensel, M. J., & Ramsey, N. F. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.10.005 · Cited by 262
Brain Functional Localization: A Survey of Image Registration Techniques
Gholipour, A., Kehtarnavaz, N., Briggs, R., Devous, M., & Gopinath, K. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.892508 · Cited by 274
Simultaneous in vivo positron emission tomography and magnetic resonance imaging
Catana, C., Procissi, D., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., Jacobs, R. E., & Cherry, S. R. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711622105 · Cited by 272
Visualization of image data from cells to organisms
Walter, T., Shattuck, D. W., Baldock, R., Bastin, M. E., Carpenter, A. E., Duce, S., Ellenberg, J., Fraser, A., Hamilton, N., Pieper, S., et al. (2010) · Nature Methods · doi:10.1038/nmeth.1431 · Cited by 266
Registration of freehand 3D ultrasound and magnetic resonance liver images
Penney, G. P., Blackall, J. M., Hamady, M. S., Sabharwal, T., Adam, A., & Hawkes, D. J. (2004) · Medical Image Analysis · doi:10.1016/j.media.2003.07.003 · Cited by 219
Self-citationTen simple rules for reporting voxel-based morphometry studies
Ridgway, G. R., Henley, S. M. D., Rohrer, J. D., Scahill, R. I., Warren, J. D., & Fox, N. C. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.01.003 · Cited by 243
“If a non-standard approach is employed, more detail is required, describing the four basic elements of image registration: the spatial transformation model; the objective function, including any regularisation terms or Bayesian priors; the optimisation algorithm; and the interpolation method (Hill et al., 2001).”
MethodBohland, J. W., Wu, C., Barbas, H., Bokil, H., Bota, M., Breiter, H. C., Cline, H. T., Doyle, J. C., Freed, P. J., Greenspan, R. J., et al. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000334 · Cited by 261
Registration of Challenging Image Pairs: Initialization, Estimation, and Decision
Yang, G., Stewart, C. V., Sofka, M., & Tsai, C.-L. (2007) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.1116 · Cited by 259
Implementation and evaluation of various demons deformable image registration algorithms on a GPU
Gu, X., Pan, H., Liang, Y., Castillo, R., Yang, D., Choi, D., Castillo, E., Majumdar, A., Guerrero, T., & Jiang, S. B. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/1/012 · Cited by 243
“To realize the clinical application of DIR, much effort has been invested to develop fast and accurate algorithms (Hill et al. , 2001; Crum et al. , 2004; Holden, 2008).”
MethodMultimodality Imaging: Beyond PET/CT and SPECT/CT
Cherry, S. R. (2009) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2009.03.001 · Cited by 238
Longitudinal stability of MRI for mapping brain change using tensor-based morphometry
Leow, A. D., Klunder, A. D., Jack, C. R., Toga, A. W., Dale, A. M., Bernstein, M. A., Britson, P. J., Gunter, J. L., Ward, C. P., Whitwell, J. L., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.013 · Cited by 214
“A solution to this problem, known as Gradwarp (GW) correction (Hajnal et al., 2001), is described and evaluated by Jovicich et al.”
MethodPET: Physics, Instrumentation, and Scanners
Cherry, S., & Dahlbom, M. (2006) · doi:10.1007/978-0-387-22529-6_1 · Cited by 236
PET/MR Imaging: Technical Aspects and Potential Clinical Applications
Torigian, D. A., Zaidi, H., Kwee, T. C., Saboury, B., Udupa, J. K., Cho, Z.-H., & Alavi, A. (2013) · Radiology · doi:10.1148/radiol.13121038 · Cited by 247
Ill-posed medicine—an introduction to image registration
Fischer, B., & Modersitzki, J. (2008) · Inverse Problems · doi:10.1088/0266-5611/24/3/034008 · Cited by 185
“, [7–17].”
Non-rigid visible and infrared face registration via regularized Gaussian fields criterion
Ma, J., Zhao, J., Ma, Y., & Tian, J. (2015) · Pattern Recognition · doi:10.1016/j.patcog.2014.09.005 · Cited by 223
Distortion correction and robust tensor estimation for MR diffusion imaging
Mangin, J.-F., Poupon, C., Clark, C., Le Bihan, D., & Bloch, I. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00079-8 · Cited by 194
“The purpose of this similarity measure is to return a value indicating how well the two slices match given a certain transformation [27,20].”
BackgroundDeformable Medical Image Registration: Setting the State of the Art with Discrete Methods
Glocker, B., Sotiras, A., Komodakis, N., & Paragios, N. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124649 · Cited by 193
Megason, S. G., & Fraser, S. E. (2003) · Mechanisms of Development · doi:10.1016/j.mod.2003.07.005 · Cited by 202
Nestle, U., Kremp, S., & Grosu, A.-L. (2006) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2006.09.011 · Cited by 214
“Registration is a process where pixels from one image (reference image) are mapped to pixels in another image (test image) by assigning the position and the associated pixel value from the reference image to the test image [48].”
BackgroundCurrent trends in medical image registration and fusion
El-Gamal, F. E.-Z. A., Elmogy, M., & Atwan, A. (2016) · Egyptian Informatics Journal · doi:10.1016/j.eij.2015.09.002 · Cited by 224
Fung, G., & Stoeckel, J. (2006) · Knowledge and Information Systems · doi:10.1007/s10115-006-0043-5 · Cited by 156
A survey of methods for 3D histology reconstruction
Pichat, J., Iglesias, J. E., Yousry, T., Ourselin, S., & Modat, M. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.004 · Cited by 207
“Further details can be found in reviews about (medical) image registration (Maintz and Viergever, 1998; Hill et al., 2001; Zi-tova and Flusser, 2003; Sotiras et al., 2013) and a report was recently presented in Viergever et al. (2016) to assess whether the goals of the field were met.”
BackgroundComparison of fMRI motion correction software tools
Oakes, T. R., Johnstone, T., Ores Walsh, K. S., Greischar, L. L., Alexander, A. L., Fox, A. S., & Davidson, R. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.058 · Cited by 182
“The need to remove this confound from the data led to efforts to measure and correct for head motion, usually with post hoc methods such as coregistration of each fMRI volume to a reference volume (Thacker et al., 1999; Jenkinson and Smith, 2001).”
Zen and the art of medical image registration: correspondence, homology, and quality
Crum, W. R., Griffin, L. D., Hill, D. L. G., & Hawkes, D. J. (2003) · NeuroImage · doi:10.1016/j.neuroimage.2003.07.014 · Cited by 186
“This minimal description does little justice to the sheer inventiveness that has been directed toward solving registration problems (Hill et al., 2001).”
BackgroundSelf-citationChen, J., Liu, Y.-H., Wei, S.-W., Bian, Z., Subramanian, S., Carass, A., Prince, J. L., & Du, Y. (2023) · Medical Image Anal. · doi:10.48550/arxiv.2307.15615 · Cited by 205
“Several review papers have covered traditional medical image registration methods extensively (Maintz and Viergever, 1998; Hill et al., 2001; Shams et al., 2010; Fluck et al., 2011; Sotiras et al., 2013; Oliveira and Tavares, 2014; Viergever et al., 2016).”
BackgroundThe morphology of anisotropic 3D-printed hydroxyapatite scaffolds
Fierz, F. C., Beckmann, F., Huser, M., Irsen, S. H., Leukers, B., Witte, F., Degistirici, Ö., Andronache, A., Thie, M., & Müller, B. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.012 · Cited by 203
MULTIMODALITY IN VIVO IMAGING SYSTEMS: Twice the Power or Double the Trouble?
Cherry, S. R. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095728 · Cited by 188
Digital Volume Correlation: Review of Progress and Challenges
Buljac, A., Jailin, C., Mendoza, A., Neggers, J., Taillandier-Thomas, T., Bouterf, A., Smaniotto, B., Hild, F., & Roux, S. (2018) · Experimental Mechanics · doi:10.1007/s11340-018-0390-7 · Cited by 305
“In the medical field (and applied mathematics), such technique is called “image registration” and appeared earlier [101, 140, 227] than in experimental mechanics [12, 206].”
InfluentialTsao, J. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815077 · Cited by 158
“PV could lead to either arch artifacts or inverted-arch artifacts, depending on the relative voxel sizes.”
BackgroundSeo, Y., Mari, C., & Hasegawa, B. H. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.001 · Cited by 198
“Software techniques have been developed that can register and fuse images from multiple sources [3-7], and are best suited for correlating images from rigid structures such as the brain [8] and skeleton [9,10].”
BackgroundImage registration and data fusion in radiation therapy
Kessler, M. L. (2006) · The British Journal of Radiology · doi:10.1259/bjr/70617164 · Cited by 165
Fast and robust registration of PET and MR images of human brain
Čı́žek, J., Herholz, K., Vollmar, S., Schrader, R., Klein, J., & Heiss, W.-D. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.01.016 · Cited by 172
Automatic Construction of 3D Statistical Deformation Models Using Non-rigid Registration
Rueckert, D., Frangi, A. F., & Schnabel, J. A. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_10 · Cited by 171
Medical image registration using deep neural networks: A comprehensive review
Boveiri, H. R., Khayami, R., Javidan, R., & Mehdizadeh, A. (2020) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2020.106767 · Cited by 179
Biological imaging in radiation therapy: role of positron emission tomography
Nestle, U., Weber, W., Hentschel, M., & Grosu, A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/1/r01 · Cited by 170
Fast Spatio-temporal Free-Form Registration of Cardiac MR Image Sequences
Perperidis, D., Mohiaddin, R., & Rueckert, D. (2004) · Functional Imaging and Modeling of the Heart · doi:10.1007/11494621_41 · Cited by 166
“(2002) and for a general review of image registration methods, see Hill et al. (2001), Lester and Arridge (1999) and Zitová and Flusser (2003).”
BackgroundEvaluation of deformable registration of patient lung 4DCT with subanatomical region segmentations
Wu, Z., Rietzel, E., Boldea, V., Sarrut, D., & Sharp, G. C. (2008) · Medical Physics · doi:10.1118/1.2828378 · Cited by 151
Assessment of a model-based deformable image registration approach for radiation therapy planning.
Kaus, M., Brock, K., Pekar, V., Dawson, L., Nichol, A., & Jaffray, D. (2007) · International Journal of Radiation Oncology, Biology, Physics · doi:10.1016/j.ijrobp.2007.01.056 · Cited by 162
A Hyperelastic Regularization Energy for Image Registration
Burger, M., Modersitzki, J., & Ruthotto, L. (2013) · SIAM Journal on Scientific Computing · doi:10.1137/110835955 · Cited by 163
AMIDE: A Free Software Tool for Multimodality Medical Image Analysis
Loening, A. M., & Gambhir, S. S. (2003) · Molecular Imaging · doi:10.1162/15353500200303133 · Cited by 1,018
“Rigid body registration is implemented inside of AMIDE through the use of fiducial reference markers and the Procrustes rigid body alignment algorithm without scaling [6].”
MethoduRP: An integrated research platform for one-stop analysis of medical images
Wu, J., Xia, Y., Wang, X., Wei, Y., Liu, A., Innanje, A., Zheng, M., Chen, L., Shi, J., Wang, L., et al. (2023) · Frontiers in Radiology · doi:10.3389/fradi.2023.1153784 · Cited by 159
“Registration Image registration is to align a moving image to a reference image, which is a critical procedure in the analyses of multimodal images and longitudinal data (45).”
MethodStructural neuroimaging as clinical predictor: A review of machine learning applications
Mateos-Pérez, J. M., Dadar, M., Lacalle-Aurioles, M., Iturria-Medina, Y., Zeighami, Y., & Evans, A. C. (2018) · NeuroImage: Clinical · doi:10.1016/j.nicl.2018.08.019 · Cited by 174
“same spatial locations) as region R for the rest of the population (Hill et al., 2001; Maintz and Viergever, 1998).”
Polymerization shrinkage assessment of dental resin composites: a literature review
Kaisarly, D., & Gezawi, M. E. (2016) · Odontology · doi:10.1007/s10266-016-0264-3 · Cited by 165
Breast image registration techniques: a survey
Guo, Y., Sivaramakrishna, R., Lu, C., Suri, J. S., & Laxminarayan, S. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-005-0016-y · Cited by 140
Yushkevich, P. A., Avants, B. B., Das, S. R., Pluta, J., Altinay, M., & Craige, C. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.12.007 · Cited by 118
“, 3D gradwarp (Hajnal et al., 2001; Jovicich et al., 2006); corrections for intensity nonuniformity due to nonuniform receiver coil sensitivity (Narayana et al.”
Anatomical imaging for radiotherapy
Evans, P. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/12/r01 · Cited by 133
“A detailed review of these and other methods for deformable image registration may be found in Hill et al (2001).”
MethodNeuroinformatics for Genome-Wide 3-D Gene Expression Mapping in the Mouse Brain
Ng, L., Pathak, S. D., Kuan, C., Lau, C., Dong, H., Sodt, A., Dang, C., Avants, B., Yushkevich, P., Gee, J. C., et al. (2007) · IEEE/ACM Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2007.1035 · Cited by 126
Expert Knowledge Guided Segmentation System for Brain MRI
Pitiot, A., Delingette, H., Thompson, P. M., & Ayache, N. (2003) · International Conference on Medical Image Computing and Computer-Assisted Intervention · doi:10.1007/978-3-540-39903-2_79 · Cited by 139
Software for image registration: Algorithms, accuracy, efficacy
Hutton, B. F., & Braun, M. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127309 · Cited by 139
Metadata
- Authors
- Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J.
- Affiliations
- Guy's Hospital (GB)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-02-15
- Volume
- 46
- Issue
- 3
- Pages
- R1-R45
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2140139548
- Cited by
- 2,093
- References
- 127
- Citations by year
- 2026: 19 · 2025: 21 · 2024: 40 · 2023: 47 · 2022: 45 · 2021: 44 · 2020: 53 · 2019: 57 · 2018: 66 · 2017: 89 · 2016: 69 · 2015: 100 · 2014: 104 · 2013: 124 · 2012: 105
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Research Portal (King's College London) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- medical image registration, multimodal image fusion, motion compensation, image-guided interventions, rigid transformation, non-rigid registration, tissue deformation, temporal image sequences
- MeSH terms
- Algorithms, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted, Registries, Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.