Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
With advances in computer performance, the use of high-resolution voxel models of the entire human body has become more frequent in numerical dosimetries of electromagnetic waves. Using magnetic resonance imaging, we have developed realistic high-resolution whole-body voxel models for Japanese adult males and females of average height and weight. The developed models consist of cubic voxels of 2 mm on each side; the models are segmented into 51 anatomic regions. The adult female model is the first of its kind in the world and both are the first Asian voxel models (representing average Japanese) that enable numerical evaluation of electromagnetic dosimetry at high frequencies of up to 3 GHz. In this paper, we will also describe the basic SAR characteristics of the developed models for the VHF/UHF bands, calculated using the finite-difference time-domain method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ahlbom, A. (1998) · Health Physics · Cited by 5,817
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Mur, G. (1981) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.1981.303970 · Cited by 2,565
Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies.
Gabriel, C. (1996) · doi:10.21236/ada303903 · Cited by 2,097
Human Respiratory Tract Model for Radiological Protection
Icrp (1994) · Annals of the ICRP · Cited by 1,767
Herbertz, J. (1998) · PubMed · Cited by 598
A study of the handset antenna and human body interaction
Okoniewski, M., & Stuchly, M. A. (1996) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.539944 · Cited by 390
Xu, X. G., Chao, T. C., & Bozkurt, A. (2000) · Health Physics · doi:10.1097/00004032-200005000-00003 · Cited by 364
Cited by
GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING ELECTRIC AND MAGNETIC FIELDS (1 Hz TO 100 kHz)
(2010) · Health Physics · doi:10.1097/hp.0b013e3181f06c86 · Cited by 2,164
De Wilde, J. P., Rivers, A. W., & Price, D. L. (2005) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2004.08.010 · Cited by 351
Xu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
Dimbylow, P. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/6/002 · Cited by 276
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
BodyParts3D: 3D structure database for anatomical concepts
Mitsuhashi, N., Fujieda, K., Tamura, T., Kawamoto, S., Takagi, T., & Okubo, K. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkn613 · Cited by 237
Zaidi, H., & Xu, X. G. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151934 · Cited by 219
“(67) from the National Institute of Information and Communications Technology (NIICT) reported an adult male model, named Nagaoka Man, and an adult female model, named Nagaoka Woman, developed from magnetic resonance images for radio-frequency electromagnetic-field dosimetry.”
MethodVoxel-based computational models of real human anatomy: a review
Caon, M. (2004) · Radiation and Environmental Biophysics · doi:10.1007/s00411-003-0221-8 · Cited by 213
Analysis of RF exposure in the head tissues of children and adults
Wiart, J., Hadjem, A., Wong, M. F., & Bloch, I. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/13/019 · Cited by 189
“VH is one of the first heads that have been built and has been intensively used since it has a 1 mm resolution but other adult head models have also been developed and recently used (Nagaoka et al 2004).”
MethodInfluentialHybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models
Lee, C., Lodwick, D., Hasenauer, D., Williams, J. L., Lee, C., & Bolch, W. E. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/001 · Cited by 184
“A review of currently available voxel phantoms was reported by Caon (2004) and in more recently published studies (Dimbylow 2005, Kramer et al 2004a, 2003, Lee et al 2006b, 2006c, Nagaoka et al 2004).”
MethodWireless power transfer approaches for medical implants: a review
Haerinia, M., & Shadid, R. (2020) · Signals · doi:10.3390/signals1020012 · Cited by 174
“[65] 2004 Body 400 MHz, 900 MHz, 2400 MHz Visible human, FDTD [66] 2004 Body/51 tissues 30 MHz–3 GHz FDTD [67] 2002 Head/10 tissues 900 MHz, 1800 MHz Visible human, FDTD”
Effects of coil orientation on the electric field induced by TMS over the hand motor area
Laakso, I., Hirata, A., & Ugawa, Y. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/1/203 · Cited by 174
“This location corresponds to the anterior wall of the central sulcus, located roughly in the middle of the hand knob, at a depth of around 2.6 cm (Duke) or 2.9 cm (Taro) below the scalp surface, which is the depth of activation of TMS observed using PET (Fox et al 2004).”
MethodInfluentialAssessing Human Exposure to Electromagnetic Fields From Wireless Power Transmission Systems
Christ, A., Douglas, M., Nadakuduti, J., & Kuster, N. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2245851 · Cited by 173
Conil, E., Hadjem, A., Lacroux, F., Wong, M. F., & Wiart, J. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/6/001 · Cited by 172
“Around 2 GHz, the whole-body-averaged SAR of the Japan Female and that of the Male are very close to the basic restriction (SAR values reach 92% and 99% of the basic restriction).”
MethodInfluentialAssessment of Human Exposure to Electromagnetic Fields: Review and Future Directions
Hirata, A., Diao, Y., Onishi, T., Sasaki, K., Ahn, S., Colombi, D., De Santis, V., Laakso, I., Giaccone, L., Wout, J., et al. (2021) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2021.3109249 · Cited by 161
Kainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109
Sani, A., Alomainy, A., & Hao, Y. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029770 · Cited by 91
Multi-disciplinary challenges in tissue modeling for wireless electromagnetic powering: a review
Bocan, K. N., Mickle, M. H., & Sejdic, E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2748338 · Cited by 41
“Data from the Visible Human project of the National Library of Medicine [58] was used in [29] and [59], and other imaging-derived models include the Virtual Family [60], [61], and several detailed body part models [24], [31], [62].”
Background
Metadata
- Authors
- Nagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2003-12-15
- Volume
- 49
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2006268511
- Cited by
- 774
- References
- 18
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.