Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
An iterative algorithm, based on recent work in compressive sensing, is developed for volume image reconstruction from a circular cone-beam scan. The algorithm minimizes the total variation (TV) of the image subject to the constraint that the estimated projection data is within a specified tolerance of the available data and that the values of the volume image are non-negative. The constraints are enforced by the use of projection onto convex sets (POCS) and the TV objective is minimized by steepest descent with an adaptive step-size. The algorithm is referred to as adaptive-steepest-descent-POCS (ASD-POCS). It appears to be robust against cone-beam artifacts, and may be particularly useful when the angular range is limited or when the angular sampling rate is low. The ASD-POCS algorithm is tested with the Defrise disk and jaw computerized phantoms. Some comparisons are performed with the POCS and expectation-maximization (EM) algorithms. Although the algorithm is presented in the context of circular cone-beam image reconstruction, it can also be applied to scanning geometries involving other x-ray source trajectories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The class trivially includes denoising and deconvolution, but also includes MRI [35], X-ray CT [13], [16], and diffraction tomography (DT).”
From Deep Convolutional Neural Network for Inverse Problems in Imaging (2017) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(2006) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/978-0-387-40065-5 · Cited by 9,008
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Alizadeh, F., & Goldfarb, D. (2003) · Mathematical Programming · doi:10.1007/s10107-002-0339-5 · Cited by 1,500
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Exact Reconstruction of Sparse Signals via Nonconvex Minimization
Chartrand, R. (2007) · IEEE Signal Processing Letters · doi:10.1109/lsp.2007.898300 · Cited by 1,277
Chen, G.-H., Tang, J., & Leng, S. (2008) · Medical Physics · doi:10.1118/1.2836423 · Cited by 1,141
Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
Sidky, E. Y., Kao, C.-M., & Pan, X. (2006) · Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · doi:10.3233/xst-2006-00155 · Cited by 1,091
Self-citationIterative Methods for Total Variation Denoising
Vogel, C. R., & Oman, M. E. (1996) · SIAM Journal on Scientific Computing · doi:10.1137/0917016 · Cited by 1,076
Accurate image reconstruction from few-views and limited-angle data in divergent-beam CTPreprint
Sidky, E. Y., Kao, C.-M., & Pan, X. (2009) · arXiv (Cornell University) · doi:10.48550/arxiv.0904.4495 · Cited by 947
Self-citation(2001) · Studies in Computational Mathematics · doi:10.1016/s1570-579x(01)80028-8 · Cited by 610
Projected Dynamical Systems and Variational Inequalities with Applications
Nagurney, A., & Zhang, D. (1996) · International Series in Operations Research & Management Science · doi:10.1007/978-1-4615-2301-7 · Cited by 609
A local update strategy for iterative reconstruction from projections
Sauer, K., & Bouman, C. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193196 · Cited by 494
Dedicated Breast CT: Radiation Dose and Image Quality Evaluation
Boone, J. M., Nelson, T. R., Lindfors, K. K., & Seibert, J. A. (2001) · Radiology · doi:10.1148/radiol.2213010334 · Cited by 468
Practical considerations for 3-D image reconstruction using spherically symmetric volume elements
Matej, S., & Lewitt, R. M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.481442 · Cited by 314
Convergence of Hybrid Steepest-Descent Methods for Variational Inequalities
Xu, H. K., & Kim, T. H. (2003) · Journal of Optimization Theory and Applications · doi:10.1023/b:jota.0000005048.79379.b6 · Cited by 312
Delaney, A. H., & Bresler, Y. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.660997 · Cited by 304
The RADON TRANSFORM and LOCAL TOMOGRAPHY
Ramm, A. G., & Katsevich, A. I. (2020) · CRC Press eBooks · doi:10.1201/9781003069331 · Cited by 301
Multidimensional digital image representations using generalized Kaiser–Bessel window functions
Lewitt, R. M. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.001834 · Cited by 292
Cone‐beam volume CT breast imaging: Feasibility study
Chen, B., & Ning, R. (2002) · Medical Physics · doi:10.1118/1.1461843 · Cited by 277
Cone-beam-CT guided radiation therapy: technical implementation
Létourneau, D., Wong, J. W., Oldham, M., Gulam, M., Watt, L., Jaffray, D. A., Siewerdsen, J. H., & Martinez, A. A. (2005) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2005.03.001 · Cited by 241
Real-time 3D computed tomographic reconstruction using commodity graphics hardware
Xu, F., & Mueller, K. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/006 · Cited by 223
Fundamental image quality limits for microcomputed tomography in small animals
Ford, N. L., Thornton, M. M., & Holdsworth, D. W. (2003) · Medical Physics · doi:10.1118/1.1617353 · Cited by 210
Daly, M. J., Siewerdsen, J. H., Moseley, D. J., Jaffray, D. A., & Irish, J. C. (2006) · Medical Physics · doi:10.1118/1.2349687 · Cited by 207
Sharp, G. C., Kandasamy, N., Singh, H., & Folkert, M. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/19/003 · Cited by 190
Total variation regulated EM algorithm [SPECT reconstruction]
Panin, V. Y., Zeng, G. L., & Gullberg, G. T. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.819305 · Cited by 183
Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro‐CT
Song, J., Liu, Q. H., Johnson, G. A., & Badea, C. T. (2007) · Medical Physics · doi:10.1118/1.2795830 · Cited by 183
Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography
Persson, M., Bone, D., & Elmqvist, H. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/318 · Cited by 161
Boone, J. M., Shah, N., & Nelson, T. R. (2004) · Medical Physics · doi:10.1118/1.1636571 · Cited by 157
Molecular imaging in small animals?roles for micro-CT
Ritman, E. L. (2002) · Journal of Cellular Biochemistry · doi:10.1002/jcb.10415 · Cited by 153
Elbakri, I. A., & Fessler, J. A. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/15/314 · Cited by 137
Accurate image reconstruction from few-view and limited-angle data in diffraction tomography
LaRoque, S. J., Sidky, E. Y., & Pan, X. (2008) · Journal of the Optical Society of America A · doi:10.1364/josaa.25.001772 · Cited by 136
Self-citationA flat-panel detector based micro-CT system: performance evaluation for small-animal imaging
Lee, S. C., Kim, H. K., Chun, I. K., Cho, M. H., Lee, S. Y., & Cho, M. H. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/24/014 · Cited by 136
Li, M., Yang, H., & Kudo, H. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/15/303 · Cited by 122
Region of interest reconstruction from truncated data in circular cone-beam CT
Yu, L., Zou, Y. S., Sidky, E. Y., Pelizzari, C. A., Munro, P., & Pan, X. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.872329 · Cited by 101
Self-citationTotal variation regulated EM algorithm
Panin, V., Zeng, G. L., & Gullberg, G. T. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1998.773841 · Cited by 100
Investigation of C‐Arm Cone‐Beam CT‐Guided Surgery of the Frontal Recess
Rafferty, M. A., Siewerdsen, J. H., Chan, Y., Moseley, D. J., Daly, M. J., Jaffray, D. A., & Irish, J. C. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000180759.52082.45 · Cited by 96
Hyperfast parallel‐beam and cone‐beam backprojection using the cell general purpose hardware
Kachelrieß, M., Knaup, M., & Bockenbach, O. (2007) · Medical Physics · doi:10.1118/1.2710328 · Cited by 96
Transmission maximum-likelihood reconstruction with ordered subsets for cone beam CT
Manglos, S. H., Gagne, G., Król, A., Thomas, F. D., & Narayanaswamy, R. A. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/7/006 · Cited by 94
Ford, E. C., Chang, J., Mueller, K. D., Sidhu, K., Todor, D. A., Mageras, G. S., Yorke, E. D., Ling, C., & Amols, H. I. (2002) · Medical Physics · doi:10.1118/1.1517614 · Cited by 92
Image reconstruction from few views by non-convex optimization
Sidky, E. Y., Chartrand, R., & Pan, X. (2007) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2007.4436889 · Cited by 48
Self-citationKole, J. S., & Beekman, F. J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/4/008 · Cited by 41
Sidky, E. Y., Reiser, I., Nishikawa, R. M., Pan, X., Chartrand, R., Kopans, D. B., & Moore, R. H. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.772796 · Cited by 28
Self-citationSidky, E. Y., & Pan, X. (2006) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2006.356484 · Cited by 28
Self-citationStatistical image reconstruction for transmission tomography using relaxed ordered subset algorithms
Kole, J. S. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/7/015 · Cited by 26
Zbijewski, W. B., & Beekman, F. J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/7/017 · Cited by 25
Effect of the data constraint on few-view, fan-beam CT image reconstruction by TV minimization
Sidky, E. Y., Kao, C.-M., & Pan, X. (2006) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2006.354372 · Cited by 25
Self-citationde Carvalho, B. M., & Herman, G. T. (2006) · Image and Vision Computing · doi:10.1016/j.imavis.2006.03.003 · Cited by 21
Three-dimensional focus of attention for iterative cone-beam micro-CT reconstruction
Benson, T. M., & Gregor, J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/18/006 · Cited by 18
Statistical reconstruction for x-ray CT systems with non-continuous detectors
Zbijewski, W. B., Defrise, M., Viergever, M. A., & Beekman, F. J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/2/007 · Cited by 18
Research works printed but not linked: 3
- Lange K, 1984, J. Comput. Assist. Tomogr., 8, 306
- Sidky E Y Pan X Kacheriess M Beekman F Müller K, 2007, 9th Int. Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, 60
- Song J, 2007, IEEE Trans. Nucl. Sci., 34, 4476
Cited by
Deep Convolutional Neural Network for Inverse Problems in Imaging
Jin, K. H., McCann, M. T., Froustey, E., & Unser, M. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2713099 · Cited by 2,529
“The class trivially includes denoising and deconvolution, but also includes MRI [38], X-ray CT [12], [14], and diffraction tomography (DT).”
BackgroundLow-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
Chen, H., Zhang, Y., Kalra, M. K., Lin, F., Chen, Y., Liao, P., Zhou, J., & Wang, G. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2715284 · Cited by 1,866
Yang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630
The ASTRA Toolbox: A platform for advanced algorithm development in electron tomography
van Aarle, W., Palenstijn, W. J., De Beenhouwer, J., Altantzis, T., Bals, S., Batenburg, K. J., & Sijbers, J. (2015) · Ultramicroscopy · doi:10.1016/j.ultramic.2015.05.002 · Cited by 973
aLow-dose CT via convolutional neural network
Chen, H., Zhang, Y., Zhang, W., Liao, P., Li, K., Zhou, J., & Wang, G. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000679 · Cited by 755
Metadata
- Authors
- Sidky, E. Y., & Pan, X.
- Affiliations
- University of Chicago (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-13
- Volume
- 53
- Issue
- 17
- Pages
- 4777-4807
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC2630711
- OpenAlex
- W1972150100
- Cited by
- 1,995
- References
- 53
- Citations by year
- 2026: 80 · 2025: 138 · 2024: 114 · 2023: 118 · 2022: 119 · 2021: 178 · 2020: 114 · 2019: 164 · 2018: 150 · 2017: 118 · 2016: 122 · 2015: 125 · 2014: 126 · 2013: 111 · 2012: 88
- FWCI
- 32.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Cancer Institute (R01CA120540)
- National Institute of Biomedical Imaging and Bioengineering (K01EB003913, R01EB000225)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Sparse and Compressive Sensing Techniques
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Keywords
- image reconstruction, total variation minimization, projection onto convex sets, cone-beam artifacts, compressed sensing, expectation-maximization comparison
- MeSH terms
- Algorithms, Computer Simulation, Humans, Image Processing, Computer-Assisted, Models, Theoretical, Radiographic Image Interpretation, Computer-Assisted, Software, X-Rays, Models, Statistical, Tomography Scanners, X-Ray Computed, Artifacts, Phantoms, Imaging, Imaging, Three-Dimensional, Cone-Beam Computed Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.