In vivo small-animal imaging using micro-CT and digital subtraction angiography
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
Small-animal imaging has a critical role in phenotyping, drug discovery and in providing a basic understanding of mechanisms of disease. Translating imaging methods from humans to small animals is not an easy task. The purpose of this work is to review in vivo x-ray based small-animal imaging, with a focus on in vivo micro-computed tomography (micro-CT) and digital subtraction angiography (DSA). We present the principles, technologies, image quality parameters and types of applications. We show that both methods can be used not only to provide morphological, but also functional information, such as cardiac function estimation or perfusion. Compared to other modalities, x-ray based imaging is usually regarded as being able to provide higher throughput at lower cost and adequate resolution. The limitations are usually associated with the relatively poor contrast mechanisms and potential radiation damage due to ionizing radiation, although the use of contrast agents and careful design of studies can address these limitations. We hope that the information will effectively address how x-ray based imaging can be exploited for successful in vivo preclinical imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Gordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,791
Principles of Computerized Tomographic Imaging
Kak, A. C., Slaney, M., & Wang, G. (2002) · Medical Physics · doi:10.1118/1.1455742 · Cited by 1,877
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
An X-ray computed tomography imaging agent based on long-circulating bismuth sulphide nanoparticles
Rabin, O., Manuel Perez, J., Grimm, J., Wojtkiewicz, G., & Weissleder, R. (2006) · Nature Materials · doi:10.1038/nmat1571 · Cited by 942
A microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
X-ray detectors for digital radiography
Yaffe, M. J., & Rowlands, J. A. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/1/001 · Cited by 781
Three-Dimensional X-Ray Microtomography
Flannery, B. P., Deckman, H. W., Roberge, W. G., & D'Amico, K. L. (1987) · Science · doi:10.1126/science.237.4821.1439 · Cited by 773
Cited by
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
Whole-body three-dimensional optoacoustic tomography system for small animals
Brecht, H.-P. F., Su, R., Fronheiser, M. P., Ermilov, S. A., Conjusteau, A., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3259361 · Cited by 304
Cancer imaging by optical coherence tomography: preclinical progress and clinical potential
Vakoc, B. J., Fukumura, D., Jain, R. K., & Bouma, B. E. (2012) · Nature Reviews Cancer · doi:10.1038/nrc3235 · Cited by 299
Iodinated blood pool contrast media for preclinical X-ray imaging applications – A review
Hallouard, F., Anton, N., Choquet, P., Constantinesco, A., & Vandamme, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.066 · Cited by 265
Current Status of Developments and Applications of Micro-CT
Ritman, E. L. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124717 · Cited by 243
Micro-CT of rodents: State-of-the-art and future perspectives
Clark, D. P., & Badea, C. T. (2014) · Physica Medica · doi:10.1016/j.ejmp.2014.05.011 · Cited by 229
“system configuration [29].”
Self-citationAdvances in functional X-ray imaging techniques and contrast agents
Chen, H., Rogalski, M. M., & Anker, J. N. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41858d · Cited by 168
In vivo small animal imaging: Current status and future prospects
Kagadis, G. C., Loudos, G., Katsanos, K., Langer, S. G., & Nikiforidis, G. C. (2010) · Medical Physics · doi:10.1118/1.3515456 · Cited by 164
Microcomputed tomography: approaches and applications in bioengineering
Boerckel, J. D., Mason, D. E., McDermott, A. M., & Alsberg, E. (2014) · Stem Cell Research & Therapy · doi:10.1186/scrt534 · Cited by 158
“, Montreal, QC, Canada) contrast agents [76].”
Influential4D microvascular imaging based on ultrafast Doppler tomography
Demené, C., Tiran, E., Sieu, L.-A., Bergel, A., Gennisson, J. L., Pernot, M., Deffieux, T., Cohen, I., & Tanter, M. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.014 · Cited by 139
“In vivo acquisitions also suffer from supplementary limitations, mostly loss of resolution, control of the ionizing dose (CT) or the use of a contrast agent (Badea et al., 2008; Edelman, 1993).”
Background
Metadata
- Authors
- Badea, C. T., Drangova, M., Holdsworth, D. W., & Johnson, G. A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-29
- Volume
- 53
- Issue
- 19
- Pages
- R319-R350
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2080799622
- Cited by
- 264
- References
- 72
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.