In vivo small-animal imaging using micro-CT and digital subtraction angiography
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
Small-animal imaging has a critical role in phenotyping, drug discovery and in providing a basic understanding of mechanisms of disease. Translating imaging methods from humans to small animals is not an easy task. The purpose of this work is to review in vivo x-ray based small-animal imaging, with a focus on in vivo micro-computed tomography (micro-CT) and digital subtraction angiography (DSA). We present the principles, technologies, image quality parameters and types of applications. We show that both methods can be used not only to provide morphological, but also functional information, such as cardiac function estimation or perfusion. Compared to other modalities, x-ray based imaging is usually regarded as being able to provide higher throughput at lower cost and adequate resolution. The limitations are usually associated with the relatively poor contrast mechanisms and potential radiation damage due to ionizing radiation, although the use of contrast agents and careful design of studies can address these limitations. We hope that the information will effectively address how x-ray based imaging can be exploited for successful in vivo preclinical imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Gordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,791
Principles of Computerized Tomographic Imaging
Kak, A. C., Slaney, M., & Wang, G. (2002) · Medical Physics · doi:10.1118/1.1455742 · Cited by 1,877
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
An X-ray computed tomography imaging agent based on long-circulating bismuth sulphide nanoparticles
Rabin, O., Manuel Perez, J., Grimm, J., Wojtkiewicz, G., & Weissleder, R. (2006) · Nature Materials · doi:10.1038/nmat1571 · Cited by 942
A microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
X-ray detectors for digital radiography
Yaffe, M. J., & Rowlands, J. A. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/1/001 · Cited by 781
Three-Dimensional X-Ray Microtomography
Flannery, B. P., Deckman, H. W., Roberge, W. G., & D'Amico, K. L. (1987) · Science · doi:10.1126/science.237.4821.1439 · Cited by 773
Computed tomography : fundamentals, system technology, image quality, applications
Kalender, W. A. (2000) · Cited by 692
Statistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691
Initial evaluation of coronary images from 320-detector row computed tomography
Rybicki, F. J., Otero, H. J., Steigner, M. L., Vorobiof, G., Nallamshetty, L., Mitsouras, D., Ersoy, H., Mather, R. T., Judy, P. F., Cai, T., et al. (2008) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-008-9308-2 · Cited by 563
Nanoparticle PET-CT Imaging of Macrophages in Inflammatory Atherosclerosis
Nahrendorf, M., Zhang, H., Hembrador, S., Panizzi, P., Sosnovik, D. E., Aikawa, E., Libby, P., Swirski, F. K., & Weissleder, R. (2008) · Circulation · doi:10.1161/circulationaha.107.741181 · Cited by 559
High resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490
Micro-Computed Tomography—Current Status and Developments
Ritman, E. L. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140130 · Cited by 360
A new ultrasound instrument for in vivo microimaging of mice
Foster, F. S., Zhang, M. Y., Zhou, Y. Q., Liu, G., Mehi, J., Cherin, E., Harasiewicz, K. A., Starkoski, B. G., Zan, L., Knapik, D. A., et al. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00567-7 · Cited by 342
Micro-CT in small animal and specimen imaging
Holdsworth, D. W., & Thornton, M. M. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)02004-8 · Cited by 334
Self-citationOptimum energies for x-ray transmission tomography of small samples
Grodzins, L. (1983) · Nuclear Instruments and Methods in Physics Research · doi:10.1016/0167-5087(83)90393-9 · Cited by 291
A Liposomal Nanoscale Contrast Agent for Preclinical CT in Mice
Mukundan, S., Ghaghada, K. B., Badea, C. T., Kao, C.-Y., Hedlund, L. W., Provenzale, J. M., Johnson, G. A., Chen, E., Bellamkonda, R. V., & Annapragada, A. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0523 · Cited by 245
Self-citationIn vivo, three-dimensional microscopy of trabecular bone
Dr. Kinney, J. H., Lane, N. E., & Haupt, D. L. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650100213 · Cited by 230
Boyd, S. K., Davison, P., Müller, R., & Gasser, J. A. (2006) · Bone · doi:10.1016/j.bone.2006.04.017 · Cited by 212
Fundamental image quality limits for microcomputed tomography in small animals
Ford, N. L., Thornton, M. M., & Holdsworth, D. W. (2003) · Medical Physics · doi:10.1118/1.1617353 · Cited by 210
Self-citationKiessling, F., Greschus, S., Lichy, M. P., Bock, M., Fink, C., Vosseler, S., Moll, J., Mueller, M. M., Fusenig, N. E., Traupe, H., et al. (2004) · Nature Medicine · doi:10.1038/nm1101 · Cited by 205
Small-Animal X-ray Dose from Micro-CT
Boone, J. M., Velazquez, O., & Cherry, S. R. (2004) · Molecular Imaging · doi:10.1162/15353500200404118 · Cited by 201
Gupta, R., Grasruck, M., Suess, C., Bartling, S. H., Schmidt, B., Stierstorfer, K., Popescu, S., Brady, T., & Flohr, T. (2006) · European Radiology · doi:10.1007/s00330-006-0156-y · Cited by 200
Micro‐CT with respiratory and cardiac gating
Badea, C., Hedlund, L. W., & Johnson, G. A. (2004) · Medical Physics · doi:10.1118/1.1812604 · Cited by 196
Self-citationSparseness prior based iterative image reconstruction for retrospectively gated cardiac micro‐CT
Song, J., Liu, Q. H., Johnson, G. A., & Badea, C. T. (2007) · Medical Physics · doi:10.1118/1.2795830 · Cited by 183
Self-citationAppleton, C. T., McErlain, D. D., Pitelka, V., Schwartz, N., Bernier, S. M., Henry, J. L., Holdsworth, D. W., & Beier, F. (2007) · Arthritis Research & Therapy · doi:10.1186/ar2120 · Cited by 174
Self-citation4-D Micro-CT of the Mouse Heart
Badea, C. T., Fubara, B. N., Hedlund, L. W., & Johnson, G. A. (2005) · Molecular Imaging · doi:10.1162/15353500200504187 · Cited by 173
Self-citationMolecular imaging in small animals?roles for micro-CT
Ritman, E. L. (2002) · Journal of Cellular Biochemistry · doi:10.1002/jcb.10415 · Cited by 171
David, V., Laroche, N., Boudignon, B. M., Lafage‐Proust, M., Alexandre, C., Ruegsegger, P., & Vico, L. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.9.1622 · Cited by 169
A quality assurance phantom for the performance evaluation of volumetric micro-CT systems
Du, L. Y., Umoh, J. U., Nikolov, H. N., Pollmann, S. I., Lee, T., & Holdsworth, D. W. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/23/021 · Cited by 165
Self-citationWiesmann, F., Ruff, J., Hiller, K.-H., Rommel, E., Haase, A., & Neubauer, S. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.2.h652 · Cited by 165
In Vivo Respiratory-Gated Micro-CT Imaging in Small-Animal Oncology Models
Cavanaugh, D., Johnson, E., Price, R. E., Kurie, J., Travis, E. L., & Cody, D. D. (2004) · Molecular Imaging · doi:10.1162/15353500200403184 · Cited by 158
Paulus, M. J., Gleason, S. S., Easterly, M. E., & Foltz, C. J. (2001) · PubMed · Cited by 146
Cowan, C. M., Aghaloo, T. L., Chou, Y., Walder, B., Zhang, X., Soo, C. B., Ting, K., & Wu, B. M. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0141 · Cited by 145
A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging
Lee, S. C., Kim, H. K., Chun, I. K., Cho, M. H., Lee, S. Y., & Cho, M. H. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/24/014 · Cited by 136
Functional CT for Quantifying Tumor Perfusion in Antiangiogenic Therapy in a Rat Model
Kan, Z., Phongkitkarun, S., Kobayashi, S., Tang, Y., Ellis, L. M., Lee, T., & Charnsangavej, C. (2005) · Radiology · doi:10.1148/radiol.2363041293 · Cited by 122
Dawson, D. K., Lygate, C. A., Saunders, J., Schneider, J. E., Ye, X., Hulbert, K., Noble, J. A., & Neubauer, S. (2004) · Circulation · doi:10.1161/01.cir.0000142049.14227.ad · Cited by 120
In Vivo mouse imaging and spectroscopy in drug discovery
Beckmann, N., Kneuer, R., Gremlich, H., Karmouty‐Quintana, H., Blé, F., & Müller, M. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1153 · Cited by 118
Chérin, E., Williams, R., Needles, A., Liu, G., White, C., Brown, A. S., Zhou, Y., & Foster, F. S. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.12.015 · Cited by 115
Prospective respiratory‐gated micro‐CT of free breathing rodents
Ford, N. L., Nikolov, H. N., Norley, C. J. D., Thornton, M. M., Foster, P. J., Drangova, M., & Holdsworth, D. W. (2005) · Medical Physics · doi:10.1118/1.2013007 · Cited by 111
Self-citationDrangova, M., Ford, N. L., Detombe, S. A., Wheatley, A., & Holdsworth, D. W. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000251572.56139.a3 · Cited by 107
Self-citationSimultaneous molecular and anatomical imaging of the mousein vivo
Goertzen, A. L., Meadors, A. K., Silverman, R. W., & Cherry, S. R. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/24/301 · Cited by 104
A new X-ray computed tomography system for laboratory mouse imaging
Paulus, M. J., Sari‐Sarraf, H., Gleason, S. S., Bobrek, M., Hicks, J. S., Johnson, D. K., Behel, J. K., Thompson, L., & Allen, W. C. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775579 · Cited by 104
Hyperfast parallel‐beam and cone‐beam backprojection using the cell general purpose hardware
Kachelrieß, M., Knaup, M., & Bockenbach, O. (2007) · Medical Physics · doi:10.1118/1.2710328 · Cited by 96
Zheng, J., Perkins, G., Kirilova, A., Allen, C., & Jaffray, D. A. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000186568.50265.64 · Cited by 95
A high‐resolution XRII‐based quantitative volume CT scanner
Holdsworth, D. W., Drangova, M., & Fenster, A. (1993) · Medical Physics · doi:10.1118/1.597038 · Cited by 92
Self-citationMcErlain, D. D., Appleton, C. T., Litchfield, R. B., Pitelka, V., Henry, J. L., Bernier, S. M., Beier, F., & Holdsworth, D. W. (2007) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2007.08.006 · Cited by 90
Self-citationMicro-Computed Tomography of the Lungs and Pulmonary-Vascular System
Ritman, E. L. (2005) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200508-080ds · Cited by 90
Chappard, C., Basillais, A., Benhamou, L., Bonassie, A., Brunet-Imbault, B., Bonnet, N., & Peyrin, F. (2006) · Medical Physics · doi:10.1118/1.2256069 · Cited by 81
Murine Lung Tumor Measurement Using Respiratory-Gated Micro-Computed Tomography
CODY, D. D., Nelson, C., Bradley, W., Wislez, M., Juroske, D. M., Price, R. E., Zhou, X., Bekele, B. N., & Kurie, J. M. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000160070.67270.05 · Cited by 79
Weber, S. M., Peterson, K. A., Durkee, B. Y., Chen, Q., Longino, M., WARNER, T. F. C. S., Lee, F. T., & Weichert, J. P. (2004) · Journal of Surgical Research · doi:10.1016/s0022-4804(03)00357-3 · Cited by 79
A microPET/CT system forinvivosmall animal imaging
Liang, H., Yang, Y., Yang, K., Wu, Y., Boone, J. M., & Cherry, S. R. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/13/015 · Cited by 75
High-resolution imaging of murine myocardial infarction with delayed-enhancement cine micro-CT
Nahrendorf, M., Badea, C. T., Hedlund, L. W., Figueiredo, J., Sosnovik, D. E., Johnson, G. A., & Weissleder, R. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01307.2006 · Cited by 69
Self-citationFord, N. L., Martin, E. L., Lewis, J. F., Veldhuizen, R. A. W., Drangova, M., & Holdsworth, D. W. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00629.2006 · Cited by 64
Self-citationDesign and performance characteristics of a digital flat-panel computed tomography system
Ross, W., CODY, D. D., & Hazle, J. D. (2006) · Medical Physics · doi:10.1118/1.2198941 · Cited by 59
Badea, C. T., Hedlund, L. W., Lin, M., Mackel, J. F. B., & Johnson, G. A. (2006) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.103 · Cited by 57
Self-citationMicroCT Liver Contrast Agent Enhancement Over Time, Dose, and Mouse Strain
Suckow, C. E., & Stout, D. (2008) · Molecular Imaging and Biology · doi:10.1007/s11307-007-0128-x · Cited by 55
Vertebrate Radiobiology (Lethal Actions and Associated Effects)
Bond, V. P., & Robertson, J. (1957) · Annual Review of Nuclear Science · doi:10.1146/annurev.ns.07.120157.001031 · Cited by 48
A comparison of x-ray detectors for mouse CT imaging
Goertzen, A. L., Nagarkar, V. V., Street, R. A., Paulus, M. J., Boone, J. M., & Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/23/004 · Cited by 46
Quantification of angiogenesis by functional computed tomography in a matrigel model in rats1
Phongkitkarun, S., Kobayashi, S., Kan, Z., Lee, T., & Charnsangavej, C. (2004) · Academic Radiology · doi:10.1016/s1076-6332(03)00728-1 · Cited by 42
Kole, J. S., & Beekman, F. J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/4/008 · Cited by 41
Practical Vessel Imaging by Computed Tomography in Live Transgenic Mouse Models for Human Tumors
Kindlmann, G., Weinstein, D. M., Jones, G., Johnson, C. R., Capecchi, M. R., & Keller, C. (2005) · Molecular Imaging · doi:10.2310/7290.2005.05166 · Cited by 41
Shofer, S. L., Badea, C. T., Auerbach, S., Schwartz, D. A., & Johnson, G. A. (2007) · Experimental Lung Research · doi:10.1080/01902140701364458 · Cited by 37
Self-citationHigh-resolution vascular imaging of the rat spine using liposomal blood pool MR agent.
Ghaghada, K. B., Bockhorst, K. H. J., Mukundan, S., Annapragada, A., & Narayana, P. A. (2007) · PubMed · Cited by 33
High-Resolution Computed Tomography of the Normal Rat Nephrogram
Kujoory, M. A., Hillman, B. J., & Barrett, H. H. (1980) · Investigative Radiology · doi:10.1097/00004424-198003000-00010 · Cited by 28
Badea, C. T., Hedlund, L. W., Mackel, J. F. B., Mao, L., Rockman, H. A., & Johnson, G. A. (2007) · Molecular Imaging · doi:10.2310/7290.2007.00022 · Cited by 28
Self-citationReduction of pulmonary compliance found with high-resolution computed tomography in irradiated mice
Guerrero, T. M., Castillo, R., Noyola-Martinez, J., Torres, M. A., Zhou, X., Guerra, R., CODY, D. D., Komaki, R. U., & Travis, E. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.10.037 · Cited by 23
Three-dimensional focus of attention for iterative cone-beam micro-CT reconstruction
Benson, T. M., & Gregor, J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/18/006 · Cited by 18
A Fluoroscopy-Based Computed Tomography Scanner for Small Specimen Research
Boone, J. M., Alexander, G. M., & Seibert, J. A. (1993) · Investigative Radiology · doi:10.1097/00004424-199306000-00015 · Cited by 13
Cited by
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
Whole-body three-dimensional optoacoustic tomography system for small animals
Brecht, H.-P. F., Su, R., Fronheiser, M. P., Ermilov, S. A., Conjusteau, A., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3259361 · Cited by 304
Cancer imaging by optical coherence tomography: preclinical progress and clinical potential
Vakoc, B. J., Fukumura, D., Jain, R. K., & Bouma, B. E. (2012) · Nature Reviews Cancer · doi:10.1038/nrc3235 · Cited by 299
Iodinated blood pool contrast media for preclinical X-ray imaging applications – A review
Hallouard, F., Anton, N., Choquet, P., Constantinesco, A., & Vandamme, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.066 · Cited by 265
Current Status of Developments and Applications of Micro-CT
Ritman, E. L. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124717 · Cited by 243
Metadata
- Authors
- Badea, C. T., Drangova, M., Holdsworth, D. W., & Johnson, G. A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-29
- Volume
- 53
- Issue
- 19
- Pages
- R319-R350
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2080799622
- Cited by
- 264
- References
- 72
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.