The Virtual Family—development of surface-based anatomical models of two adults and two children for dosimetric simulations
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
The objective of this study was to develop anatomically correct whole body human models of an adult male (34 years old), an adult female (26 years old) and two children (an 11-year-old girl and a six-year-old boy) for the optimized evaluation of electromagnetic exposure. These four models are referred to as the Virtual Family. They are based on high resolution magnetic resonance (MR) images of healthy volunteers. More than 80 different tissue types were distinguished during the segmentation. To improve the accuracy and the effectiveness of the segmentation, a novel semi-automated tool was used to analyze and segment the data. All tissues and organs were reconstructed as three-dimensional (3D) unstructured triangulated surface objects, yielding high precision images of individual features of the body. This greatly enhances the meshing flexibility and the accuracy with respect to thin tissue layers and small organs in comparison with the traditional voxel-based representation of anatomical models. Conformal computational techniques were also applied. The techniques and tools developed in this study can be used to more effectively develop future models and further improve the accuracy of the models for various applications. For research purposes, the four models are provided for free to the scientific community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical Heat Transfer and Fluid Flow
Patankar, S. V. (2018) · CRC Press eBooks · doi:10.1201/9781482234213 · Cited by 23,360
Numerical Heat Transfer and Fluid Flow
Hsu, C.-J. (1981) · Nuclear Science and Engineering · doi:10.13182/nse81-a20112 · Cited by 15,125
Yee, K. (1966) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1966.1138693 · Cited by 15,008
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“This is particularly important for interfaces with high dielectric contrast, such as skin, fat, bone and muscle tissue (Gabriel et al 1996), in order to correctly render reflections, interference effects and hot spots at tissue boundaries with high dielectric contrast, such as skin–fat–muscle…”
BackgroundKromeyer-Hauschild, K., Wabitsch, M., Kunze, D., Geller, F., Geiß, H. C., Hesse, V., von Hippel, A., Jaeger, U., Johnsen, D., Korte, W., et al. (2001) · Monatsschrift Kinderheilkunde · doi:10.1007/s001120170107 · Cited by 2,175
Valentin, J. (2002) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00002-2 · Cited by 1,754
Report of the task group on reference man
(1979) · Annals of the ICRP · doi:10.1016/0146-6453(79)90123-4 · Cited by 1,706
Ackerman, M. J. (1998) · Proceedings of the IEEE · doi:10.1109/5.662875 · Cited by 725
The Involution of the Ageing Human Thymic Epithelium is Independent of Puberty: A Morphometric Study
STEINMANN, G. G., KLAUS, B., & MÜLLER‐HERMELINK, H. ‐. (1985) · Scandinavian Journal of Immunology · doi:10.1111/j.1365-3083.1985.tb01916.x · Cited by 453
Cited by
A technical guide to tDCS, and related non-invasive brain stimulation tools
Woods, A. J., Antal, A., Bikson, M., Boggio, P. S., Brunoni, A. R., Celnik, P., Cohen, L. G., Fregni, F., Herrmann, C. S., Kappenman, E. S., et al. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.11.012 · Cited by 1,439
Determinants of the electric field during transcranial direct current stimulation
Opitz, A., Paulus, W., Will, S., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.033 · Cited by 690
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/5287 · Cited by 520
“Pregnant women models at three gestational stages presented in Christ et al (2012) are included in the Virtual Population.”
BackgroundMethodSelf-citationXu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
Self-citationA 64‐channel 3T array coil for accelerated brain MRI
Keil, B., Blau, J. N., Biber, S., Hoecht, P., Tountcheva, V., Setsompop, K., Triantafyllou, C., & Wald, L. L. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24427 · Cited by 260
Quantitative assessment of the effects of high‐permittivity pads in 7 Tesla MRI of the brain
Teeuwisse, W. M., Brink, W. M., & Webb, A. G. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23108 · Cited by 225
“EM simulations were performed using a head model (‘‘Duke’’) (17) with appropriate conductivity and dielectric properties assigned to each tissue and a finite-difference time-domain method with commercially available software (xFDTD, Remcom Inc.”
MethodMultiparametric imaging with heterogeneous radiofrequency fields
Cloos, M. A., Knoll, F., Zhao, T., Block, K. T., Bruno, M., Wiggins, G. C., & Sodickson, D. K. (2016) · Nature Communications · doi:10.1038/ncomms12445 · Cited by 184
Fast multigrid-based computation of the induced electric field for transcranial magnetic stimulation
Laakso, I., & Hirata, A. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7753 · Cited by 174
“The TMS-induced electric fields are determined in Caucasian male (DUKE) and female (ELLA) models (Christ et al 2010). Originally, the models comprise surface representation of tissues that has been constructed from MR images of a 34-year-old Caucasian male and a 26-year-old Caucasian female. The same models have been…”
MethodAssessing Human Exposure to Electromagnetic Fields From Wireless Power Transmission Systems
Christ, A., Douglas, M., Nadakuduti, J., & Kuster, N. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2245851 · Cited by 173
“2, are available with special software to move and rotate them and to export them in a generic data format, which can be used with the finite-difference–time-domain (FDTD) algorithm at different mesh resolutions [50], [59].”
BackgroundMethodSelf-citationModulating Human Procedural Learning by Cerebellar Transcranial Direct Current Stimulation
Ferrucci, R., Brunoni, A. R., Parazzini, M., Vergari, M., Rossi, E., Fumagalli, M., Mameli, F., Rosa, M., Giannicola, G., Zago, S., et al. (2013) · The Cerebellum · doi:10.1007/s12311-012-0436-9 · Cited by 167
“We used a realistic human model of the Virtual Family [22], based on high-resolution MRI for a healthy volunteer (“Ella”: a 26-year-old female) and segmented into a voxelbased format at a resolution of 1 mm.”
MethodAssessment of Human Exposure to Electromagnetic Fields: Review and Future Directions
Hirata, A., Diao, Y., Onishi, T., Sasaki, K., Ahn, S., Colombi, D., De Santis, V., Laakso, I., Giaccone, L., Wout, J., et al. (2021) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2021.3109249 · Cited by 161
Self-citationKainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109
“Food and Drug Administration (FDA), and several other groups, consists of more than ten different anatomical models developed from MRI data of healthy volunteers, including male and female adults and children of various ages, an obese male, an elderly male, a pregnant woman, and newborn [11].”
InfluentialSelf-citationLauer, O., Frei, P., Gosselin, M., Joseph, W., Röösli, M., & Fröhlich, J. (2013) · Bioelectromagnetics · doi:10.1002/bem.21782 · Cited by 65
Galappaththige, S., Gray, R. A., Costa, C. M., Niederer, S., & Pathmanathan, P. (2022) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1010541 · Cited by 45
“However, all publications reviewed fell into one of these categories, and important PSMs from other fields do so as well, for example Heartflow [1] is a PSM-CT and the Virtual Family [60] is a PSM-VC.”
BackgroundMulti-disciplinary challenges in tissue modeling for wireless electromagnetic powering: a review
Bocan, K. N., Mickle, M. H., & Sejdic, E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2748338 · Cited by 41
“[58] was used in [29], [59], and other imaging-derived models include the Virtual Family [60], [61], and several detailed body part models [24], [31], [62].”
Method
Metadata
- Authors
- Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., Kiefer, B., Schmitt, P., Hollenbach, H.-P., Shen, J., Oberle, M., Szczerba, D., Kam, A., Guag, J. W., & Kuster, N.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2009-12-17
- Volume
- 55
- Issue
- 2
- Pages
- N23-N38
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2140796340
- Cited by
- 1,439
- References
- 43
- FWCI
- 36.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.