Weighted iterative reconstruction for magnetic particle imaging
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Magnetic particle imaging (MPI) is a new imaging technique capable of imaging the distribution of superparamagnetic particles at high spatial and temporal resolution. For the reconstruction of the particle distribution, a system of linear equations has to be solved. The mathematical solution to this linear system can be obtained using a least-squares approach. In this paper, it is shown that the quality of the least-squares solution can be improved by incorporating a weighting matrix using the reciprocal of the matrix-row energy as weights. A further benefit of this weighting is that iterative algorithms, such as the conjugate gradient method, converge rapidly yielding the same image quality as obtained by singular value decomposition in only a few iterations. Thus, the weighting strategy in combination with the conjugate gradient method improves the image quality and substantially shortens the reconstruction time. The performance of weighting strategy and reconstruction algorithms is assessed with experimental data of a 2D MPI scanner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, E., Bai, Z., Bischof, C., Blackford, L. S., Demmel, J., Dongarra, J., Du Croz, J., Greenbaum, A., Hammarling, S., McKenney, A., et al. (1999) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898719604 · Cited by 4,435
Craven, P., & Wahba, G. (1978) · Numerische Mathematik · doi:10.1007/bf01404567 · Cited by 3,388 · cited 1×
“For choosing the regularization parameter λ, several methods were proposed (Hansen 1998, Hansen and O’Leary 1993, Craven and Wahba 1979).”
MethodThe Use of the L-Curve in the Regularization of Discrete Ill-Posed Problems
Hansen, P. C., & O’Leary, D. P. (1993) · SIAM Journal on Scientific Computing · doi:10.1137/0914086 · Cited by 3,137 · cited 1×
“For choosing the regularization parameter λ, several methods were proposed (Hansen 1998, Hansen and O’Leary 1993, Craven and Wahba 1979).”
MethodRank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion
Hansen, P. C. (1998) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898719697 · Cited by 2,909
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,003 · cited 3×
“…can be written in a matrix–vector notation Gc = û, (1) with vectors c := (c(rn))N−1n=0 , (2) û := (û(fk))M−1k=0 , (3) and the system matrix G := (ŝ(fk, rn))k=0,...,M−1;n=0,...,N−1 , (4) which consists of the so-called system function ŝ(fk, rn), as introduced by Gleich and Weizenecker (2005).”
BackgroundSelf-citationSmoothing noisy data with spline functions
Wahba, G. (1975) · Numerische Mathematik · doi:10.1007/bf01437407 · Cited by 1,443
Three-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651 · cited 2×
“The third drive field required for 3D encoding (Weizenecker et al 2009) is not used in this work.”
MethodSelf-citationSignal encoding in magnetic particle imaging: properties of the system function
Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J. (2009) · BMC Medical Imaging · doi:10.1186/1471-2342-9-4 · Cited by 345 · cited 3×
“The individual frequency components show similarity to 2D tensor products of Chebyshev polynomials (Rahmer et al 2009).”
BackgroundSelf-citationA simulation study on the resolution and sensitivity of magnetic particle imaging
Weizenecker, J., Borgert, J., & Gleich, B. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/21/001 · Cited by 267 · cited 3×
“Although a mathematical model of the system function exists (Weizenecker et al 2007, Knopp et al 2009) and first promising 1D model-based reconstruction results were recently published by Knopp et al (2010), measuring the system function still results in higher accuracy for 2D imaging.”
MethodSelf-citationModel-Based Reconstruction for Magnetic Particle Imaging
Knopp, T., Sattel, T. F., Biederer, S., Rahmer, J., Weizenecker, J., Gleich, B., Borgert, J., & Buzug, T. M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2021612 · Cited by 184 · cited 1×
“Although a mathematical model of the system function exists (Weizenecker et al 2007, Knopp et al 2009) and first promising 1D model-based reconstruction results were recently published by Knopp et al (2010), measuring the system function still results in higher accuracy for 2D imaging.”
MethodSelf-citationMaximum likelihood, least squares, and penalized least squares for PET
Kaufman, L. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.232249 · Cited by 180 · cited 2×
“However, even for non-uniform weights, the least-squares approach (5) is a good approximation of maximum likelihood estimation, provided that the noise level is low (Kaufman 1993).”
BackgroundMethodTrajectory analysis for magnetic particle imaging
Knopp, T., Biederer, S., Sattel, T., Weizenecker, J., Gleich, B., Borgert, J., & Buzug, T. M. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/2/014 · Cited by 171 · cited 2×
“Although a mathematical model of the system function exists (Weizenecker et al 2007, Knopp et al 2009) and first promising 1D model-based reconstruction results were recently published by Knopp et al (2010), measuring the system function still results in higher accuracy for 2D imaging.”
MethodSelf-citationExperimental results on fast 2D-encoded magnetic particle imaging
Gleich, B., Weizenecker, J., & Borgert, J. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/6/n01 · Cited by 128 · cited 1×
“Regarding the resulting image quality, it was observed by Gleich et al (2008) that ‘sharper but noisier’ images can be obtained by normalizing the rows of the system matrix and the corresponding entries of the measurement vector.”
MethodSelf-citationConvergence properties of ART and SOR algorithms
Elsner, L., Koltracht, I., & Lancaster, P. (1991) · Numerische Mathematik · doi:10.1007/bf01385772 · Cited by 25 · cited 1×
“The convergence speed of the Kaczmarz method was investigated in various papers (Marti 1979, Trummer 1981, Elsner et al 1991).”
Method
Cited by
Magnetic particle imaging: current developments and future directions
Panagiotopoulos, N., Vogt, F., Barkhausen, J., Buzug, T. M., Duschka, R. L., Lüdtke-Buzug, K., Ahlborg, M., Bringout, G., Debbeler, C., Gräser, M., et al. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s70488 · Cited by 289
“19 Here, λ denotes the regularization parameter that controls the influence of the regularization.”
BackgroundSelf-citationHigh-performance iron oxide nanoparticles for magnetic particle imaging – guided hyperthermia (hMPI)
Bauer, L. M., Situ, S. F., Griswold, M. A., & Samia, A. C. S. (2016) · Nanoscale · doi:10.1039/c6nr01877g · Cited by 222
Analysis of a 3-D System Function Measured for Magnetic Particle Imaging
Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2188639 · Cited by 171
Self-citationKaul, M., Weber, O., Heinen, U., Reitmeier, A., Mummert, T., Jung, C., Raabe, N., Knopp, T., Ittrich, H., & Adam, G. (2015) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-0034-1399344 · Cited by 42
Self-citation
Metadata
- Authors
- Knopp, T., Rahmer, J., Sattel, T. F., Biederer, S., Weizenecker, J., Gleich, B., Borgert, J., & Buzug, T. M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2010-02-17
- Volume
- 55
- Issue
- 6
- Pages
- 1577-1589
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2007068462
- Cited by
- 199
- References
- 14
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.